VectorStar® MS4640A Series VNAsMicrowave Vector Network Analyzers : Appendix A â€” System Limits and Parameters : Descriptions
 
Descriptions
VectorStar MS4640A Series VNA System Parameters and Limits
Limit Parameter Group - Limit Parameter Name
Range - Default Value - Units - Modify Per
SCPI Command
Broadband/Millimeter Wave - Broadband/Millimeter Wave Mode State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:SENSe{1-16}:TSET[:STATe]
Broadband/Millimeter Wave - Broadband/Millimeter Wave Test Set Type State
Range: NA
Default Value: 1
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:SENSe{1-16}:TSET:BBANd
Calibration LRL Parameters - LRL Calibration Breakpoint Frequency
Range: 7E4 to 7E10
Default Value: 3.00000000000E+009
Parameter Units: Hertz
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:LRL:FREQuency:BREakpoint
Calibration LRL Parameters - LRL Calibration Device Type
Range: NA
Default Value: LINE
Parameter Units: LINE | MATCH | DEVICE1 | DEVICE2
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:LRL:DEVice{1-4}:TYPe
Calibration LRL Parameters - LRL Calibration Line Loss
Range: NA
Default Value: 0.00000000000E+000
Parameter Units: dB/mm
Modify Per: Port-Pair Per Channel
:SENSe{1-16}:CORRection:COLLect:LRL:DEVice{1-4}:PORT{12}:LINE:LOSS
Calibration LRL Parameters - LRL Calibration Loss Reference Frequency
Range: 7E4 to 7E10
Default Value: 0.00000000000E+000
Parameter Units: Hertz
Modify Per: Port-Pair Per Channel
:SENSe{1-16}:CORRection:COLLect:LRL:DEVice{1-4}:PORT{12}:LINE:FREQuency
Calibration LRL Parameters - LRL Calibration Matching Device Capacitance
Range: 0 to 1E12
Default Value: 0.00000000000E+000
Parameter Units: Farads
Modify Per: Port
:SENSe{1-16}:CORRection:COLLect:LRL:DEVice{1-4}:PORT{1-2}:MATCH:C0
Calibration LRL Parameters - LRL Calibration Matching Device Impedance
Range: 1E-4 to 1E10
Default Value: 5.00000000000E+001
Parameter Units: Ohms
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:LRL:DEVice{1-4}:PORT{1-2}:MATCH:Z0
Calibration LRL Parameters - LRL Calibration Matching Device Inductance
Range: 0 to 1E12
Default Value: 0.00000000000E+000
Parameter Units: Henrys
Modify Per: Port
:SENSe{1-16}:CORRection:COLLect:LRL:DEVice{1-4}:PORT{1-2}:MATCH:L0
Calibration LRL Parameters - LRL Calibration Matching Device Offset Distance
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Meters
Modify Per: Port
:SENSe{1-16}:CORRection:COLLect:LRL:DEVice{1-4}:PORT{1-2}:MATCH:OFFS
Calibration LRL Parameters - LRL Calibration Matching Device Resistance
Range: MPND
Default Value: 5.00000000000E+001
Parameter Units: Ohms
Modify Per: Port
:SENSe{1-16}:CORRection:COLLect:LRL:DEVice{1-4}:PORT{1-2}:MATCH:R
Calibration LRL Parameters - LRL Calibration Match-Port Set
Range: NA
Default Value: PORT1
Parameter Units: PORT1 | PORT2
Modify Per: Port-Pair Per Channel
:SENSe{1-16}:CORRection:COLLect:LRL:DEVice{1-4}:MATCH:PORT
Calibration LRL Parameters - LRL Calibration Number of Bands
Range: 1 or 2
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:LRL:BANDs:COUNt
Calibration LRL Parameters - LRL Calibration Open-Like Reflection Offset
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Meters
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:LRL:OPEN:OFFS
Calibration LRL Parameters - LRL Calibration Port-Pair Line Length
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Meters
Modify Per: Port-Pair Per Channel
:SENSe{1-16}:CORRection:COLLect:LRL:DEVice{1-4}:PORT{12}:LINE:LENGth
Calibration LRL Parameters - LRL Calibration Reference Plane Location
Range: NA
Default Value: END
Parameter Units: MIDDLE | END
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:LRL:REFPlane
Calibration LRL Parameters - LRL Calibration Short-Link Offset
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Meters
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:LRL:SHORT:OFFS
Calibration LRL Parameters - Reflection Type Band 1
Range: NA
Default Value: OPEN
Parameter Units: OPENlike | SHORTlike | BOTH
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:LRL:BAND1:REFLection:TYPe
Calibration LRL Parameters - Reflection Type Band 2
Range: NA
Default Value: OPEN
Parameter Units: OPENlike | SHORTlike | BOTH
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:LRL:BAND2:REFLection:TYPe
Calibration Parameters - Adapter Removal Length Seconds
Range: MPND
Default Value: NA
Parameter Units: Seconds
Modify Per: Channel
:CALCulate{1-16}:CORRection:ADAPter:REMoval:LENGth
Calibration Parameters - Automatic ECal Module Orientation Detection State
Range: NA
Default Value: 1
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:ECAL:AUTOmatic:ORIentation[:STATe]
Calibration Parameters - Calibration AutoCal Manual Orientation Mode
Range: NA
Default Value: L1R2
Parameter Units: L1R2 | R1L2
Modify Per: Port-Pair Per Channel
:SENSe{1-16}:CORRection:COLLect:ECAL:ORIentation
Calibration Parameters - Calibration AutoCal True-Thru State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:ECAL:TRUEthru
Calibration Parameters - Calibration Correction Coefficient
Range: NA
Default Value: NA
Parameter Units: ED1 | EP1S | ET11 | ET21 | EP2L | EX21 | ED2 | EP2S | ET22 | ET12 | EP1L | EX12
Modify Per: Channel
:SENSe{1-16}:CORRection:COEFficient
Calibration Parameters - Calibration Line Type
Range: NA
Default Value: COAX
Parameter Units: COAXial | MICROstrip | NONDISpersive | WAVEguide
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect[:METHod]:LINE
Calibration Parameters - Calibration Load Type
Range: NA
Default Value: FIX
Parameter Units: FIXed | SLIDing
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect[:METHod]:LOAD
Calibration Parameters - Calibration Method
Range: NA
Default Value: SOLT
Parameter Units: AUTOcal | ACLIght | LRL | LRM | SOLR | SOLT | SSLT | SSST
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:METHod
Calibration Parameters - Calibration Port or Port Pair
Range: NA
Default Value: PORTP12
Parameter Units: PORT1 | PORT2 | PORTP12
Modify Per: Port Per Channel or Port-Pair Per Channel
:SENSe{1-16}:CORRection:COLLect[:METHod]:PORT
Calibration Parameters - Calibration Reference Impedance
Range: 1E-4 to 1E10
Default Value: 5.00000000000E+001
Parameter Units: Ohms
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:REFErence:Z0
Calibration Power Parameters - Flat Power Correction Calibration Target Power Level
Range: MPNF
Default Value: 0.000000E+000
Parameter Units: dB
Modify Per: Port Per Channel
:SOURce{1-16}:POWer:PORT{1-2}:CORRection:TARGet
Calibration Power Parameters - Flat Power Correction Data
Range: NA
Default Value: NA
Parameter Units: NA
Modify Per: Port Per Channel
:SOURce{1-16}:POWer:PORT{1-2}:CORRection:DATA?
Calibration Power Parameters - Flat Power Correction State
Range: NA
Default Value: 0
Parameter Units: 1 | 0
Modify Per: Port Per Channel
:SOURce{1-16}:POWer:PORT{1-2}:CORRection[:STATe]?
Calibration Power Parameters - Flat Power Correction Target Power Level
Range: MPNF
Default Value: 0.000000E+000
Parameter Units: dB
Modify Per: Port Per Channel
:SOURce{1-16}:POWer:PORT{1-2}:CORRection:TARGet?
Calibration Waveguide Parameters - Calibration Kit Waveguide Dielectric
Range: MPND
Default Value: 1.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:WAVeguide:DIELectric
Calibration Waveguide Parameters - Calibration Kit Waveguide Open Capacitance Term
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:WAVeguide:OPEN:C0
Calibration Waveguide Parameters - Calibration Kit Write File Write State
Range: NA
Default Value: NA
Parameter Units: COAXial | NONDISpersive | WAVEguide
SOLX | SSLT | SSST
CID2 | CID3 | CIDK | CIDN | CIDS | CIDT | CIDV | CID1 | CID716 | CIDG | CIDN75 | CIDWR10 | CIDWR12 | | CIDWR15 | CIDU1 | CIDU2
:MMEMory:WRITE:CKIT
Calibration Waveguide Parameters - Test Set Waveguide Type
Range: NA
Default Value: WR10E
Parameter Units: WR1.5 | WR2.2 | WR3 | WR5 | WR6 | WR8 | WR10 | WR10E | WR12 | WR12E | WR15
Modify Per: Channel
:SENSe{1-16}:TSET:WGType
Calibration Waveguide Parameters - Waveguide Calibration Kit Cutorr Frequency
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Hertz
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:WAVeguide:FREQuency
Calibration Waveguide Parameters - Waveguide Calibration Kit Label
Range: NA
Default Value: WR10
Parameter Units: Alphanumeric Characters
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:WAVeguide:LABel
Calibration Waveguide Parameters - Waveguide Calibration Kit Load Inductance
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Henrys
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:WAVeguide:LOAD:L0
Calibration Waveguide Parameters - Waveguide Calibration Kit Load Offset Distance
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Meters
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:WAVeguide:LOAD:OFFSet
Calibration Waveguide Parameters - Waveguide Calibration Kit Load Resistance
Range: MPND
Default Value: 5.00000000000E+001
Parameter Units: Ohms
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:WAVeguide:LOAD:R
Calibration Waveguide Parameters - Waveguide Calibration Kit Offset
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Meters
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:WAVeguide:OPEN:OFFSet
Calibration Waveguide Parameters - Waveguide Calibration Kit Open Capacitance 1
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:WAVeguide:OPEN:C1
Calibration Waveguide Parameters - Waveguide Calibration Kit Open Capacitance 2
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:WAVeguide:OPEN:C2
Calibration Waveguide Parameters - Waveguide Calibration Kit Open Capacitance 3 Term
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:WAVeguide:OPEN:C3
Calibration Waveguide Parameters - Waveguide Calibration Kit Serial Number
Range: NA
Default Value: XXXXXX
Parameter Units: Alphanumeric Characters
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:WAVeguide:SERial
Calibration Waveguide Parameters - Waveguide Calibration Kit Short 2 Offset
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Meters
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:WAVeguide:SHORT2:OFFSet
Calibration Waveguide Parameters - Waveguide Calibration Kit Short 3 Offset
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Meters
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:WAVeguide:SHORT3:OFFSet
Calibration Waveguide Parameters - Waveguide Calibration Kit Sliding Load Minimum Frequency
Range: MPND
Default Value: 2.00000000000E+009
Parameter Units: Hertz
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:WAVeguide:SLOAD:MINF
Calibration Waveguide Parameters - Waveguide Calibration Kits Short 1 Offset
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Meters
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:WAVeguide:SHORT1:OFFSet
Calibration Waveguide Parameters - Waveguide Kit
Range: NA
Default Value: WR10
Parameter Units: WR10 | WR12 | WR15 | USER1 | USER2 | USER3 | USER4 | USER5 | USER6 | USER7 | USER8
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:WAVeguide:KIT
Channel Parameters - Averaging Count
Range: 1 to 1024
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:AVERage:COUNt
Channel Parameters - Averaging State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:SENSe{1-16}:AVERage[:STATe]
Channel Parameters - Averaging Type Mode
Range: NA
Default Value: POIN
Parameter Units: POINtbypoint | SWEepbysweep
Modify Per: Channel
:SENSe{1-16}:AVERage:TYPe
Channel Parameters - Channel Display Layout
Range: NA
Default Value: R1C1
Parameter Units: R1C1 | R1C2 | R2C1 | R1C3 | R3C1 | R2C2C1 | R2C1C2 | C2R2R1 | C2R1R2 | R1C4 | R4C1 | R2C2 | R2C3 | R3C2 | R2C4 | R4C2 | R3C3 | R5C2 | R2C5 | R4C3 | R3C4 | R4C4
Modify Per: Channel
:DISPlay:SPLit
Channel Parameters - Channel Number Active
Range: NA
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Instrument
:DISPlay:WINDow{1-16}:ACTivate
Channel Parameters - Measurement Points
Range: Range depends on the maximum points setting.
When 25000 points is set, 2 to 25,000.
When 100000 points is set, 2 to 100,000.
Default Value: 201
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:SWEep:POINts
Channel Parameters - Number of Channels Displayed
Range: For 25,000 point mode, 1 to 16 channels.
For 100,000 point mode, 1 channel.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Instrument
:DISPlay:COUNt
Channel Parameters - Receiver Configuration
Range: NA
Default Value: STAN
Parameter Units: STANdard | MSOURce | MMWBBand
Modify Per: Channel
:SENSe{1-16}:RECEiver:CONFiguration
Channel Parameters - RF Correction State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:SENSe{1-16}:CORRection:STATe
Channel Parameters - Spur Reduction State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:SENSe{1-16}:SPUR:REDuction[:STATe]
Channel Parameters - Test Set RF Divisor
Range: MPNI. Limited by the band equation.
Default Value: 6
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:TSET:RF:DIVisor
Connector Parameters - Load 1 Standard C0 Capacitance
Range: 0 to 1E12
Default Value: 0.00000000000E+000
Parameter Units: Farads
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD1:C0
Connector Parameters - Load 1 Standard Impedance
Range: 1E-4 to 1E10
Default Value: 5.00000000000E+001
Parameter Units: Ohms
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD1:Z0
Connector Parameters - Load 1 Standard L0 Inductance Coefficient
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD1:L0
Connector Parameters - Load 1 Standard L1 Inductance Coefficient
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD1:L1
Connector Parameters - Load 1 Standard L2 Inductance Coefficient
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD1:L2
Connector Parameters - Load 1 Standard L3 Inductance
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD1:L3?
Connector Parameters - Load 1 Standard L3 Inductance
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD1:L3
Connector Parameters - Load 1 Standard Label
Range: NA
Default Value: NA
Parameter Units: Alphanumeric Characters
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD1:LABEL
Connector Parameters - Load 1 Standard Offset
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Meters
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD1:OFFS
Connector Parameters - Load 1 Standard Resistance
Range: MPND
Default Value: 5.00000000000E+001
Parameter Units: Ohms
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD1:R
Connector Parameters - Load 1 Standard Serial Number
Range: NA
Default Value: XXXXXX
Parameter Units: Alphanumeric Characters
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD1:SERial
Connector Parameters - Load 2 Standard C0 Capacitance
Range: 0 to 1E12
Default Value: 0.00000000000E+000
Parameter Units: Farads
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD2:C0
Connector Parameters - Load 2 Standard Impedance
Range: 1E-4 to 1E10
Default Value: 5.00000000000E+001
Parameter Units: Ohms
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD2:Z0
Connector Parameters - Load 2 Standard L1 Inductance
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD2:L0
Connector Parameters - Load 2 Standard L1 Inductance
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD2:L1
Connector Parameters - Load 2 Standard L2 Inductance
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD2:L2
Connector Parameters - Load 2 Standard L3 Inductance Coefficient
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD2:L3
Connector Parameters - Load 2 Standard Label
Range: NA
Default Value: NA
Parameter Units: Alphanumeric Characters
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD2:LABEL
Connector Parameters - Load 2 Standard Offset
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Ohms
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD2:OFFS
Connector Parameters - Load 2 Standard Resistance
Range: 0 to 1E10
Default Value: 5.00000000000E+001
Parameter Units: Ohms
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD2:R
Connector Parameters - Load 2 Standard Serial Number Input
Range: NA
Default Value: XXXXXX
Parameter Units: Alphanumeric Characters
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD2:SERial
Connector Parameters - Load Standard Load 1 or Load 2 Set
Range: NA
Default Value: NA
Parameter Units: LOAD1 | LOAD2
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:LOAD:SELect
Connector Parameters - Short 1 Standard L0 Inductance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT1:L0
Connector Parameters - Short 1 Standard L1 Inductance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT1:L1
Connector Parameters - Short 1 Standard L2 Inductance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT1:L2
Connector Parameters - Short 1 Standard L3 Inductance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT1:L3
Connector Parameters - Short 1 Standard Offset Distance
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Meters
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT1:OFFS
Connector Parameters - Short 1 Standard Serial Number
Range: NA
Default Value: XXXXXX
Parameter Units: Alphanumeric Characters
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT1:SERial
Connector Parameters - Short 2 Standard Inductance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT2:L0
Connector Parameters - Short 2 Standard L1 Inductance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT2:L1
Connector Parameters - Short 2 Standard L2 Inductance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT2:L2
Connector Parameters - Short 2 Standard L3 Inductance
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT2:L3
Connector Parameters - Short 2 Standard Offset
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Meters
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT2:OFFS
Connector Parameters - Short 3 Standard L0 Inductance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT3:L0
Connector Parameters - Short 3 Standard L1 Inductance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT3:L1
Connector Parameters - Short 3 Standard L2 Inductance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT3:L2
Connector Parameters - Short 3 Standard L3 Inductance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT3:L3
Connector Parameters - Short 3 Standard Offset Distance
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Meters
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT3:OFFS
Connector Parameters - Short 3 Standard Serial Number
Range: NA
Default Value: XXXXXX
Parameter Units: Alphanumeric Characters
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT3:SERial
Connector Parameters - Short Standard L0 Inductance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT:L0
Connector Parameters - Short Standard L1 Inductance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT:L1
Connector Parameters - Short Standard L2 Inductance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT:L2
Connector Parameters - Short Standard L3 Inductance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT:L3
Connector Parameters - Short Standard Label Input
Range: NA
Default Value: NA
Parameter Units: Alphanumeric Characters
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT:LABEL
Connector Parameters - Short Standard Offset Ohms
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Ohms
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT:OFFS
Connector Parameters - Short Standard Serial Number
Range: NA
Default Value: XXXXXX
Parameter Units: Alphanumeric Characters
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:SHORT:SERial
Data Format and File Parameters - Data File Heading State
Range: NA
Default Value: 1
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Instrument
:FORMat:DATA:HEADing[:STATe]
Data Format and File Parameters - Data Numeric Format Mode
Range: NA
Default Value: ASC
Parameter Units: ASCii | REAL | REAL32
Modify Per: Instrument
:FORMat:DATA
Data Format and File Parameters - Data Significant Byte Order Mode
Range: NA
Default Value: SWAP
Parameter Units: NORMal | SWAPped
Modify Per: Instrument
:FORMat:BORDer
Display Parameters - Display Background Normal Color
Range: 0 to 255
Default Value: 0,0,0
Parameter Units: Integers between 0 and 255
Modify Per: Channel
:DISPlay:COLor:NORMal:BACK
Display Parameters - Display Color Inverted
Range: 0 to 255
Default Value: 255,255,255
Parameter Units: Integers between 0 and 255
Modify Per: Channel
:DISPlay:COLor:INVert:BACK
Display Parameters - Display Color Main Graticule
Range: 0 to 255
Default Value: 255,255,255
Parameter Units: Integers between 0 and 255
Modify Per: Channel
:DISPlay:COLor:NORMal:GRATicule:MAIN
Display Parameters - Display Frequency Information State
Range: NA
Default Value: 1
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Instrument
:DISPlay:ANNotation:FREQuency[:STATe]
Display Parameters - Display Main Graticule Inverted Color
Range: 0 to 255
Default Value: 0,0,0
Parameter Units: Integers between 0 and 255
Modify Per: Channel
:DISPlay:COLor:INVert:GRATicule:MAIN
Display Parameters - Display Screen Object Color Invert/Normal State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Instrument
:DISPlay:COLor:INVert[:STATe]
Display Parameters - Display Sub Graticule Color Normal
Range: 0 to 255
Default Value: 100,100,100
Parameter Units: Integers between 0 and 255
Modify Per: Channel
:DISPlay:COLor:NORMal:GRATicule:SUB
Display Parameters - Display Sub Graticule Inverted Color
Range: 0 to 255
Default Value: 100,100,100
Parameter Units: Integers between 0 and 255
Modify Per: Channel
:DISPlay:COLor:INVert:GRATicule:SUB
External Source Parameters - External Source Control State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: External Source Per Instrument
:SENSe{1-16}:SOURCe{1-4}:EXTernal[:STATe]
External Source Parameters - External Source CW Mode State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:SENSe{1-16}:OFFSet:EXTernal{1-4}:CW[:STATe]
External Source Parameters - External Source Frequency Divisor
Range: MPNI. Limited by the band equation. The band equation changes depending on if CW is set.
If CW is off, the band equation equals:
Source = (Multiplier/Divisor) * (Frequency + Offset Frequency).
If CW is on,the band e
:SENSe{1-16}:OFFSet:EXTernal{1-4}[:FREQuency]:DIVisor
External Source Parameters - External Source Frequency Divisor
Range: Depends on multiple source equation.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:OFFSet{1-50}:EXTernal{1-4}[:FREQuency]:DIVisor
External Source Parameters - External Source Frequency Multiplier
Range: MPNI. Limited by the band equation.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:OFFSet{1-50}:EXTernal{1-4}[:FREQuency]:MULTiplier
External Source Parameters - External Source Frequency Multiplier
Range: MPNI. Limited by the band equation.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:OFFSet:EXTernal{1-4}[:FREQuency]:MULTiplier
External Source Parameters - External Source Offset Frequency
Range: Depends on multiple source equation.
Default Value: 0.00000000000E+000
Parameter Units: Hertz
Modify Per: Channel
:SENSe{1-16}:OFFSet{1-50}:EXTernal{1-4}[:FREQuency]:OFFSet
External Source Parameters - External Source Power Level
Range: -15.0 to +30.0
Default Value: Depends on the external source used.
Parameter Units: dBm
Modify Per: External Source
:SOURCe{1-4}:EXTernal:POWer
External Source Parameters - External Sources Fast Trigger Mode State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Instrument
:SOURce:ALL:EXTernal:FTRIGger[:STATe]
Frequency-Based Segment Parameters - Frequency-Based Segment Add
Range: Minimum Segment Range = 2 Hz; Minimum Segment Points = 2 points; For first segment, Minimum Segment Frequency = Minimum Instrument Frequency. For highest frequency entered, Maximum Segment Frequency = Maximum Instrument Frequency. For the first se
:SENSe{1-16}:FSEGMent:ADD
Frequency-Based Segment Parameters - Frequency-Based Segment CW Frequency
Range: Minimum Instrument Frequency to Maximum Instrument Frequency
Default Value: 7.00000000000E+004
Parameter Units: Hertz
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent{1-50}:FREQuency[:CW][:FIXed]
Frequency-Based Segment Parameters - Frequency-Based Segment CW Frequency
Range: Minimum Instrument Frequency to Maximum Instrument Frequency
Default Value: 70000
Parameter Units: Hertz
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent:FREQuency[:CW][:FIXed]
Frequency-Based Segment Parameters - Frequency-Based Segment CW Mode
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent:CWMODe[:STATe]
Frequency-Based Segment Parameters - Frequency-Based Segment CW Mode State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent{1-50}:CWMODe[:STATe]
Frequency-Based Segment Parameters - Frequency-Based Segment Display Mode
Range: NA
Default Value: FREQ
Parameter Units: FREQbase | INDEXbase
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent:DISPlay
Frequency-Based Segment Parameters - Frequency-Based Segment IF Bandwidth
Range: 1 to 1E6
Default Value: 1.00000000000E+005
Parameter Units: Hertz
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent{1-50}:BWIDth[:RESolution]
Frequency-Based Segment Parameters - Frequency-Based Segment IF Bandwidth
Range: 1 to 1E6
Default Value: 1.00000000000E+005
Parameter Units: Hertz
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent:BWIDth[:RESolution]
Frequency-Based Segment Parameters - Frequency-Based Segment Number of Sweep Points
Range: Range depends on if CW mode is set.
If CW is set, 1 (one) point.
If in sweep mode (or non-CW mode), range is from 2 (two) points to Maximum Instrument Points.
Default Value: 15 or 1 depending on CW mode.
Parameter Uni
:SENSe{1-16}:FSEGMent{1-50}:SWEep:POINt
Frequency-Based Segment Parameters - Frequency-Based Segment Power Level
Range: -30 to +30
Default Value: Default value depends on model and installed options: <BulletedIndented4>MS4647A with options 51, 61, or 62 = -10 dBm<BulletedIndented4>All other MS4647As = -3 dBm<BulletedIndented4>MS4642A and MS4644A = +5 dBm
Param
:SENSe{1-16}:FSEGMent{1-50}:POWer:PORT{1-2}[:LEVel][:IMMediate][:AMPlitude]
Frequency-Based Segment Parameters - Frequency-Based Segment Power Level
Range: -30 to +30
Default Value: Default value depends on model and installed options: <BulletedIndented4>MS4647A with options 51, 61, or 62 = -10 dBm<BulletedIndented4>All other MS4647As = -3 dBm<BulletedIndented4>MS4642A and MS4644A = +5 dBm
Param
:SENSe{1-16}:FSEGMent:POWer:PORT{1-2}[:LEVel][:IMMediate][:AMPlitude]
Frequency-Based Segment Parameters - Frequency-Based Segment Span Type
Range: NA
Default Value: STARTSTOP
Parameter Units: STARTSTOP | STARTSTEP
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent{1-50}:SPAntype
Frequency-Based Segment Parameters - Frequency-Based Segment Span Type
Range: NA
Default Value: STARTSTOP
Parameter Units: STARTSTOP | STARTSTEP
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent:SPAntype
Frequency-Based Segment Parameters - Frequency-Based Segment Start
Range: Minimum Instrument Frequency to (Maximum Instrument Frequency minus Minimum Frequency Step Size)
Default Value: 7.00000000000E+004
Parameter Units: Hertz
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent:FREQuency:FSTArt
Frequency-Based Segment Parameters - Frequency-Based Segment Start Frequency
Range: Minimum Instrument Frequency to (Maximum Instrument Frequency minus Minimum Frequency Step Size)
Default Value: 7.00000000000E+004
Parameter Units: Hertz
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent{1-50}:FREQuency:FSTArt
Frequency-Based Segment Parameters - Frequency-Based Segment Start Frequency
Range: Minimum Instrument Frequency to (Maximum Instrument Frequency minus Minimum Frequency Step Size)
Default Value: 7.00000000000E+004
Parameter Units: Hertz
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent:FREQuency:STARt
Frequency-Based Segment Parameters - Frequency-Based Segment State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent{1-50}[:STATe]
Frequency-Based Segment Parameters - Frequency-Based Segment State
Range: NA
Default Value: 1
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent[:STATe]
Frequency-Based Segment Parameters - Frequency-Based Segment Step
Range: Minimum Frequency Step Size to (Maximum Instrument Frequency minus Minimum Instrument Frequency)
Default Value: Depends on installed option. <BulletedIndented4>With Low Frequency Extension Option 070 = 7.14280714286E+008 <BulletedIndented4>Witho
:SENSe{1-16}:FSEGMent:FREQuency:FSTEp
Frequency-Based Segment Parameters - Frequency-Based Segment Step Size
Range: Minimum Frequency Step Size to (Maximum Instrument Frequency minus Minimum Instrument Frequency)
Default Value: Depends on installed option. <BulletedIndented4>With Low Frequency Extension Option 070 = 7.14280714286E+008 <BulletedIndented4>Witho
:SENSe{1-16}:FSEGMent{1-50}:FREQuency:FSTEp
Frequency-Based Segment Parameters - Frequency-Based Segment Stop
Range: (Minimum Instrument Frequency + Minimum Frequency Step Size) to Maximum Instrument Frequency
Default Value: 1.00000000000E+010
Parameter Units: Hertz
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent:FREQuency:FSTOp
Frequency-Based Segment Parameters - Frequency-Based Segment Stop Frequency
Range: (Minimum Instrument Frequency + Minimum Frequency Step Size) to Maximum Instrument Frequency
Default Value: 1.00000000000E+010
Parameter Units: Hertz
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent:FREQuency:STOP
Frequency-Based Segment Parameters - Frequency-Based Segment Stop Frequency
Range: (Minimum Instrument Frequency + Minimum Frequency Step Size) to Maximum Instrument Frequency
Default Value: 1.00000000000E+010
Parameter Units: Hertz
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent{1-50}:FREQuency:FSTOp
Frequency-Based Segment Parameters - Frequency-Based Segment Sweep Averaging Count
Range: 1 to 1024
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent{1-50}:AVERage:COUNt
Frequency-Based Segment Parameters - Frequency-Based Segment Sweep Averaging Count
Range: 1 to 1024
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Frequency Segment
:SENSe{1-16}:FSEGMent:AVERage:COUNt
Frequency-Based Segment Parameters - Frequency-Based Segment Sweep Points
Range: Range depends on if CW mode is set.
If CW is set, 1 (one) point.
If in sweep mode (or non-CW mode), range is from 2 (two) points to Maximum Instrument Points.
Default Value: 15 or 1 depending on span type.
Parameter U
:SENSe{1-16}:FSEGMent:SWEep:POINt
Gain Compession Parameters - Gain Compression Point Value
Range: MPNF
Default Value: 1.000000E+000
Parameter Units: dB
Modify Per: Trace
:CALCulate{1-16}[:SELected]:GCOMpression:PVALue
Gain Compession Parameters - Gain Compression Reference Level
Range: MPNF
Default Value: 0.000000E+000
Parameter Units: dB
Modify Per: Trace
:CALCulate{1-16}[:SELected]:GCOMpression:REFerence:VALue
Gain Compession Parameters - Gain Compression Reference Type
Range: NA
Default Value: MAXG
Parameter Units: MAXGain | PHOLd | PINput
Modify Per: Trace
:CALCulate{1-16}[:SELected]:GCOMpression:REFerence
Gain Compession Parameters - Gain Compression Self Normalization State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Trace
:CALCulate{1-16}[:SELected]:GCOMpression:SNORmalize[:STATe]
Gain Compession Parameters - Gain Compression S-Parameter
Range: NA
Default Value: NA
Parameter Units: S11 | S12 | S21 | S22
Modify Per: Trace
:CALCulate{1-16}[:SELected]:GCOMpression:PARameter
Gain Compession Parameters - Gain Compresson Compression Point Indicator State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Trace
:CALCulate{1-16}[:SELected]:GCOMpression:INDicator[:STATe]
GPIB Network Parameters - External Source GPIB Address
Range: 0 to 30
Default Value: The default value depends on which source is being used: <BulletedIndented4>External Source 1 = Address 4 <BulletedIndented4>External Source 2 = Address 5 <BulletedIndented4>External Source 3 = Address 2 <BulletedIndented4
:SOURCe{1-4}:EXTernal:ADDRess
GPIB Network Parameters - GPIB Address Frequency Counter
Range: 0 to 30
Default Value: 7
Parameter Units: Unitless Number
Modify Per: Instrument
:SYSTem:COMMunicate:GPIB:FCOUNter:ADDRess
GPIB Network Parameters - GPIB Address Instrument
Range: 0 to 30
Default Value: 6
Parameter Units: Unitless Number
Modify Per: Instrument
:SYSTem:COMMunicate:GPIB:ADDRess
GPIB Network Parameters - GPIB Address Power Meter
Range: 0 to 30
Default Value: 13
Parameter Units: Unitless Number
Modify Per: Instrument
:SYSTem:COMMunicate:GPIB:PMETer:ADDRess
IFBW Parameter - IF Bandwidth
Range: 1 to 1E6. The system will automatically select the closest IF bandwidth from the following options: 1, 3, 10, 30, 100, 300 Hz; 1, 3, 10, 30, 100, 300 kHz; and 1 MHz.
Default Value: 1.00000000000E+003
Parameter Units: Hertz
Modify Per: Ch
:SENSe{1-16}:BWIDth[:RESolution]
IFBW Parameters - IF Bandwidth Enhancer State
Range: NA
Default Value: 1
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Instrument
:SENSe:BANDwidth:ENHancer[:STATe]
IFBW Parameters - IF Bandwidth Resolution
Range: 1 to 1E6. The system will automatically select the closest IF bandwidth from the following options: 1, 3, 10, 30, 100, 300 Hz; 1, 3, 10, 30, 100, 300 kHz; and 1 MHz.
Default Value: 1.00000000000E+003
Parameter Units: Hertz
Modify Per: Ch
:SENSe{1-16}:BANDwidth[:RESolution]
Index-Based Segment Parameters - Index-Based Segment Add New
Range: NA
Default Value: NA
Parameter Units: NA
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent:ADD
Index-Based Segment Parameters - Index-Based Segment CW Frequency
Range: Minimum Instrument Frequency to Maximum Instrument Frequency
Default Value: 7.00000000000E+004
Parameter Units: Hertz
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent:FREQuency[:CW][:FIXed]
Index-Based Segment Parameters - Index-Based Segment CW Mode State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent{1-50}:CWMODe[:STATe]
Index-Based Segment Parameters - Index-Based Segment CW Mode State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent:CWMODe[:STATe]
Index-Based Segment Parameters - Index-Based Segment Frequency Step Size
Range: 0 Hz to Maximum Instrument Frequency
Default Value: 7.14280714286E+008
Parameter Units: Hertz
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent:FREQuency:FSTEp
Index-Based Segment Parameters - Index-Based Segment Frequency Step Size
Range: Minimum Frequency Step Size to (Maximum Instrument Frequency minus Minimum Instrument Frequency)
Default Value: 7.14280714286E+008
Parameter Units: Hertz
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent{1-50}:FREQuency:FSTEp
Index-Based Segment Parameters - Index-Based Segment IF Bandwidth
Range: 1 to 1E6
Default Value: 1.00000000000E+005
Parameter Units: Hertz
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent{1-50}:BWIDth[:RESolution]
Index-Based Segment Parameters - Index-Based Segment IF Bandwidth
Range: 1 to 1E6
Default Value: 1.00000000000E+005
Parameter Units: Hertz
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent:BWIDth[:RESolution]
Index-Based Segment Parameters - Index-Based Segment Number of Sweep Points
Range: The range depends Maximum Instrument Points setting:<BulletedIndented4>If set to 25,000, the range = 0 to 24,999<BulletedIndented4>If set to 100,000, the range = 0 to 99,999.
Default Value: 15
Parameter Units: Integer
Modify Per: Index Seg
:SENSe{1-16}:ISEGMent:SWEep:POINt
Index-Based Segment Parameters - Index-Based Segment Power Level
Range: -30 to +30
Default Value: Default value depends on model and installed options: <BulletedIndented4>MS4647A with options 51, 61, or 62 = -10 dBm<BulletedIndented4>All other MS4647As = -3 dBm<BulletedIndented4>MS4642A and MS4644A = +5 dBm
Param
:SENSe{1-16}:ISEGMent{1-50}:POWer:PORT{1-2}[:LEVel][:IMMediate][:AMPlitude]
Index-Based Segment Parameters - Index-Based Segment Power Level
Range: -30 to +30
Default Value: Default value depends on model and installed options: <BulletedIndented4>MS4647A with options 51, 61, or 62 = -10 dBm<BulletedIndented4>All other MS4647As = -3 dBm<BulletedIndented4>MS4642A and MS4644A = +5 dBm
Param
:SENSe{1-16}:ISEGMent:POWer:PORT{1-2}[:LEVel][:IMMediate][:AMPlitude]
Index-Based Segment Parameters - Index-Based Segment Span Type
Range: NA
Default Value: STARTSTOP
Parameter Units: STARTSTOP | STARTSTEP
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent{1-50}:SPAntype
Index-Based Segment Parameters - Index-Based Segment Span Type
Range: NA
Default Value: STARTSTOP
Parameter Units: STARTSTOP | STARTSTEP
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent:SPAntype
Index-Based Segment Parameters - Index-Based Segment Start Frequency
Range: Minimum Instrument Frequency to Maximum Instrument Frequency
Default Value: 7.00000000000E+004
Parameter Units: Hertz
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent{1-50}:FREQuency[:CW][:FIXed]
Index-Based Segment Parameters - Index-Based Segment Start Frequency
Range: Range = Minimum Instrument Frequency to Maximum Instrument Frequency. Step Size = 0 Hz to Maximum Instrument Frequency.
Default Value: 7.00000000000E+004
Parameter Units: Hertz
Modify Per: Index-Segment
:SENSe{1-16}:ISEGMent:FREQuency:FSTArt
Index-Based Segment Parameters - Index-Based Segment Start Frequency
Range: Range = Minimum Instrument Frequency to Maximum Instrument Frequency. Step Size = 0 Hz to Maximum Instrument Frequency.
Default Value: 7.00000000000E+004
Parameter Units: Hertz
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent{1-50}:FREQuency:FSTArt
Index-Based Segment Parameters - Index-Based Segment Start Index
Range: The range depends Maximum Instrument Points setting:<BulletedIndented4>If set to 25,000, the range = 0 to 24,999<BulletedIndented4>If set to 100,000, the range = 0 to 99,999.
Default Value: 0
Parameter Units: Unitless Number
Modify Per: In
:SENSe{1-16}:ISEGMent:INDex:STARt
Index-Based Segment Parameters - Index-Based Segment Start Index
Range: The range depends Maximum Instrument Points setting:<BulletedIndented4>If set to 25,000, the range = 0 to 24,999<BulletedIndented4>If set to 100,000, the range = 0 to 99,999.
Default Value: 0
Parameter Units: Integer
Modify Per: Index Segm
:SENSe{1-16}:ISEGMent:INDex:ACTive:STARt?
Index-Based Segment Parameters - Index-Based Segment State
Range: NA
Default Value: 1
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent[:STATe]
Index-Based Segment Parameters - Index-Based Segment State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent{1-50}[:STATe]
Index-Based Segment Parameters - Index-Based Segment Stop Frequency
Range: Range = Minimum Instrument Frequency to Maximum Instrument Frequency. Step Size = 0 Hz to Maximum Instrument Frequency.
Default Value: 1.00000000000E+010
Parameter Units: Hertz
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent:FREQuency:FSTOp
Index-Based Segment Parameters - Index-Based Segment Stop Frequency
Range: Range = Minimum Instrument Frequency to Maximum Instrument Frequency. Step Size = 0 Hz to Maximum Instrument Frequency.
Default Value: 1.00000000000E+010
Parameter Units: Hertz
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent{1-50}:FREQuency:FSTOp
Index-Based Segment Parameters - Index-Based Segment Stop Index
Range: The range depends Maximum Instrument Points setting:<BulletedIndented4>If set to 25,000, the range = 0 to 24,999<BulletedIndented4>If set to 100,000, the range = 0 to 99,999.
Default Value: 14
Parameter Units: Unitless Number
Modify Per: I
:SENSe{1-16}:ISEGMent:INDex:STOP
Index-Based Segment Parameters - Index-Based Segment Stop Index
Range: The range depends Maximum Instrument Points setting:<BulletedIndented4>If set to 25,000, the range = 0 to 24,999<BulletedIndented4>If set to 100,000, the range = 0 to 99,999.
Default Value: 14
Parameter Units: Integer
Modify Per: Index Seg
:SENSe{1-16}:ISEGMent:INDex:ACTive:STOP?
Index-Based Segment Parameters - Index-Based Segment Sweep Averaging Count
Range: 1 to 1024
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent:AVERage:COUNt
Index-Based Segment Parameters - Index-Based Segment Sweep Averaging Count
Range: 1 to 1024
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent{1-50}:AVERage:COUNt
Index-Based Segment Parameters - Index-Based Segments Sweep Points
Range: 1 to maximum number of instrument points depending on CW mode. The maximum number of instrument points is either 25,000 or 100,000 depending on maximum points setting.
Default Value: 15
Parameter Units: Integer
Modify Per: Index Segment
:SENSe{1-16}:ISEGMent{1-50}:SWEep:POINt
Index-Based Segment Parameters - Internal Source 1 CW Mode State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:SENSe{1-16}:OFFSet:INTernal{1}:CW[:STATe]
Index-Based Segment Parameters - Internal Source 1 Frequency Divisor
Range: Depends on multiple source equation.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:OFFSet{1-50}:INTernal{1}[:FREQuency]:DIVisor
Internal Source Configuration - Internal Source 1 Frequency Divisor
Range: MPNI. Limited by the band equation.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:OFFSet:INTernal{1}[:FREQuency]:DIVisor
Internal Source Configuration - Internal Source 1 Frequency Multiplier
Range: MPNI. Limited by the band equation.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:OFFSet:INTernal{1}[:FREQuency]:MULTiplier
Internal Source Configuration - Internal Source 1 Frequency Multiplier
Range: MPNI. Limited by the band equation.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:OFFSet{1-50}:INTernal{1}[:FREQuency]:MULTiplier
Internal Source Configuration - Internal Source 1 Offset Frequency
Range: Depends on the multiple source equation.
Default Value: 0.00000000000E+000
Parameter Units: Hertz
Modify Per: Channel
:SENSe{1-16}:OFFSet{1-50}:INTernal{1}[:FREQuency]:OFFSet
Internal Source Configuration - Internal Source 1 or 2 Offset Frequency
Range: MPND. Limited by the band equation.
Default Value: 0.00000000000E+000
Parameter Units: Hertz
Modify Per: Channel
:SENSe{1-16}:OFFSet:INTernal{1}[:FREQuency]:OFFSet
Isolation Coefficient - Isolation Coefficient Data State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:SENSe{1-16}:CORRection:ISOLation:STATe
LAN Configuration - Ethernet Gateway TCPIP Address
Range: 0.0.0.0 to 255.255.255.255
Default Value: Varies with installation.
Parameter Units: Alphanumeric Characters
Modify Per: Instrument
:SYSTem:COMMunicate:TCPIP:GATE?
LAN Configuration - Ethernet MAC Address
Range: NA
Default Value: Varies with individual instrument.
Parameter Units: Alphanumeric Characters
Modify Per: Instrument
:SYSTem:COMMunicate:TCPIP:HDW?
LAN Configuration - Ethernet Mask TCPIP Address
Range: 0.0.0.0 to 255.255.255.255
Default Value: Varies with installation.
Parameter Units: Integer
Modify Per: Instrument
:SYSTem:COMMunicate:TCPIP:MASK?
LAN Configuration - Ethernet TCPIP Address
Range: 0.0.0.0 to 255.255.255.255
Default Value: Varies with installation.
Parameter Units: Alphanumeric Characters
Modify Per: Instrument
:SYSTem:COMMunicate:TCPIP:ADDRess?
LAN Configuration - Ethernet TCPIP Port Address
Range: MPNI
Default Value: 5001
Parameter Units: Unitless Number
Modify Per: Instrument
:SYSTem:COMMunicate:TCPIP:PORT
LAN Configuration - USB Address
Range: NA
Default Value: NA
Parameter Units: Alphanumeric Characters
Modify Per: Instrument
:SYSTem:COMMunicate:USB:ADDRess?
LC Network Configuration - LC Network Capacitance
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Farads
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork{1-50}:C
LC Network Configuration - LC Network Capacitance
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Farads
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork:C
LC Network Configuration - LC Network Inductance
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Henrys
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork{1-50}:L
LC Network Configuration - LC Network Inductance
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Henrys
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork:L
LC Network Configuration - LC Network Type
Range: NA
Default Value: LSCP
Parameter Units: LSCP | CSLP | CPLS | LPCS | RS | RP | TLine | S2Pfile
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork:TYPe
Limit Line Configuration - Display Limit Line Color Inverted
Range: 0 to 255
Default Value: 255,0,0
Parameter Units: Integers between 0 and 255
Modify Per: Channel
:DISPlay:COLor:INVert:LIMit
Limit Line Configuration - Display Limit Line Color Normal
Range: 0 to 255
Default Value: 255,0,0
Parameter Units: Integers between 0 and 255
Modify Per: Channel
:DISPlay:COLor:NORMal:LIMit
Limit Line Configuration - Limit Display State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Trace
:CALCulate{1-16}[:SELected]:LIMit:DISPlay[:STATe]
Limit Line Configuration - Limit Failure Indication on Auxiliary IO Connector State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Instrument
:CONTrol:AUXio:LIMit[:STATe]
Limit Line Configuration - Limit Line Failure Sign State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Limit Line
:DISPlay:FSIGn[:STATe]
Limit Line Configuration - Limit Line Polarity Auxiliary IO Port
Range: NA
Default Value: POS
Parameter Units: POSitive | NEGative
Modify Per: Limit Line
:CONTrol:AUXio:LIMit:POLarity
Limit Line Configuration - Limit Line Segment
Range: NA
Default Value: NA
Parameter Units: Y1, Y2 | Y1, Y2, Y1sub, Y2sub
Modify Per: Trace
:CALCulate{1-16}[:SELected]:LIMit:SEGMent:DEFine
Limit Line Configuration - Limit Line Segment Add
Range: NA
Default Value: NA
Parameter Units: NONE | UPPER | LOWER
Start and stop time, frequency, or distance for X1 and X2
Modify Per: Limit Line
:CALCulate{1-16}[:SELected]:LIMit:SEGMent:ADD
Limit Line Configuration - Limit Testing State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Trace
:CALCulate{1-16}[:SELected]:LIMit[:STATe]
Marker Configuration - Marker Statistics Display State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:CALCulate{1-16}:PARameter{1-16}:MSTatistics
Marker Configuration - Marker Stimulus Range Center Value
Range: NA
Default Value: NA
Parameter Units: NA
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:SET:CENTer
Marker Configuration - Marker Stimulus Range Start Value
Range: NA
Default Value: NA
Parameter Units: NA
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:SET:STARt
Marker Configuration - Marker Stimulus Range Stop Value
Range: NA
Default Value: NA
Parameter Units: NA
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:SET:STOP
Marker Configuration - Marker Table State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Trace
:CALCulate:MARKer:TABle[:STATe]
Marker Configuration - Marker Value Set
Range: Depends on the parameter setting:<BulletedIndented4>Frequency = Minimum Instrument Frequency to the Maximum Instrument Frequency<BulletedIndented4>Time = 1E-9 to 4E-9 Seconds<BulletedIndented4>Distance = -29.965E-3 to 1.1988 Meters
Default Value
:CALCulate{1-16}[:SELected]:MARKer{1-13}:X
Marker Configuration - Marker Value Set
Range: The range is user-defined by a start and stop frequency, a start and stop distance, or a start and stop time .
Default Value: For the X-axis, the default is the Minimum Instrument Frequency.
Parameter Units: Hertz, Meters, or Seconds
Modif
:CALCulate{1-16}:PARameter{1-16}:MARKer{1-13}:X
Marker Configuration - Reference Level from Active Marker Response
Range: NA
Default Value: NA
Parameter Units: NA
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:SET:REFLevel
Marker Parameters - Marker All State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:ALL[:STATe]
Marker Parameters - Marker Coupling
Range: NA
Default Value: 0
Parameter Units: 1 | 01 | ON | OFF
Modify Per: Channel
:CALCulate{1-16}:MARKer:COUPle
Marker Parameters - Marker Discrete Mode State
Range: NA
Default Value: 1
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Trace
:CALCulate{1-16}:PARameter{1-16}:MARKer:DISCrete
Marker Parameters - Marker Display State
Range: NA
Default Value: 1
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Marker
:CALCulate{1-16}[:SELected]:MARKer{1-13}[:STATe]
Marker Parameters - Marker Display State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Marker
:CALCulate{1-16}:PARameter{1-16}:MARKer{1-13}[:STATe]
Marker Parameters - Marker Move
Range: NA
Default Value: NA
Parameter Units: CENTer | REFmarker | STARt | STOP
Modify Per: Marker
:CALCulate{1-16}[:SELected]:MARKer{1-13}:MOVe
Marker Parameters - Marker Reference Level Mode
Range: NA
Default Value: NA
Parameter Units: CENTer | REFmarker | STARt | STOP
Modify Per: Marker
:CALCulate{1-16}[:SELected]:MARKer{1-13}:SET
Marker Search Configuration - Marker Search Bandwidth Shape Factor High Value
Range: MPNF
Default Value: 0.000000E+000
Parameter Units: Depends on display type
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:SEArch:BANDwidth:SHAPe:HIGH
Marker Search Configuration - Marker Search Range All Markers State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:SEArch:RANGe:ALL[:STATe]
Marker Search Configuration - Marker Search Range Start Value
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Hertz, Meters, or Seconds
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:SEArch:RANGe:STARt:X
Marker Search Configuration - Marker Search Range State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Trace
:CALCulate{1-16}[:SELected]:MARKer:SEArch:RANGe[:STATe]
Marker Search Configuration - Marker Search Range Stop Value
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Hertz, Meters, or Seconds
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:SEArch:RANGe:STOP:X
Marker Search Configuration - Marker Search Search Tracking State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Trace
:CALCulate{1-16}[:SELected]:MARKer:SEArch:TRACKing[:STATe]
Marker Search Configuration - Marker Search Target Search Mode
Range: NA
Default Value: TARG
Parameter Units: TARGet | LEFT | RIGHT
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:TSEArch
Marker Search Configuration - Marker Search Target Search Transition Value
Range: NA
Default Value: BOTH
Parameter Units: POSitive | NEGative | BOTH
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:TSEArch:TRANsition
Marker Search Configuration - Marker Search Target Search Value
Range: MPNF
Default Value: 0.000000E+000
Parameter Units: Depends on display type
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:TSEArch:TARget
Marker Search Configuration - Marker Search Type
Range: NA
Default Value: MAX
Parameter Units: MAX | MIN | PEAK | TARGet
Modify Per: Marker
:CALCulate{1-16}[:SELected]:MARKer:SEArch
Marker Search Parameters - Marker Search Bandwidth Shape Factor Low Value
Range: MPNF
Default Value: 0.000000E+000
Parameter Units: Depends on display type
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:SEArch:BANDwidth:SHAPe:LOW
Marker Search Parameters - Marker Search Bandwidth Shape Factor Shape
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Marker
:CALCulate{1-16}[:SELected]:MARKer:SEArch:BANDwidth:SHAPe[:STATe]
Marker Search Parameters - Marker Search Bandwidth State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Marker
:CALCulate{1-16}[:SELected]:MARKer:SEArch:BANDwidth[:STATe]
Marker Search Parameters - Marker Search Bandwidth Value
Range: MPNF
Default Value: 0.000000E+000
Parameter Units: Depends on display type
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:SEArch:BANDwidth:DEFine
Marker Search Parameters - Marker Search Multiple Peak Excursion Value
Range: MPNF
Default Value: 0.000000E+000
Parameter Units: dB
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:MPSEArch:EXCursion
Marker Search Parameters - Marker Search Multiple Peak Polarity
Range: NA
Default Value: POS
Parameter Units: POSitive | NEGative | BOTH
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:MPSEArch:POLarity
Marker Search Parameters - Marker Search Multiple Peak Threshold Value
Range: MPNF
Default Value: 0.000000E+000
Parameter Units: dB
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:MPSEArch:THREshold
Marker Search Parameters - Marker Search Multiple Target Transition Value
Range: NA
Default Value: BOTH
Parameter Units: POSitive | NEGative | BOTH
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:MTSEArch:TRANsition
Marker Search Parameters - Marker Search Multiple Target Value
Range: MPNI
Default Value: 0.000000E+000
Parameter Units: Depends on display type
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:MTSEArch:TARget
Marker Search Parameters - Marker Search Notch Bandwidth Value
Range: MPNF
Default Value: 0.000000E+000
Parameter Units: Depends on display type
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:SEArch:NOTCh:DEFine
Marker Search Parameters - Marker Search Notch Calculation State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Marker
:CALCulate{1-16}[:SELected]:MARKer:SEArch:NOTCh[:STATe]
Marker Search Parameters - Marker Search Notch Shape Factor High Value
Range: MPNF
Default Value: 0.000000E+000
Parameter Units: Depends on display type
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:SEArch:NOTCh:SHAPe:HIGH
Marker Search Parameters - Marker Search Notch Shape Factor Low Value
Range: MPNF
Default Value: 0.000000E+000
Parameter Units: Depends on display type
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:SEArch:NOTCh:SHAPe:LOW
Marker Search Parameters - Marker Search Notch Shape Factor State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Marker
:CALCulate{1-16}[:SELected]:MARKer:SEArch:NOTCh:SHAPe[:STATe]
Marker Search Parameters - Marker Search Peak Search
Range: NA
Default Value: PEAK
Parameter Units: PEAK | LEFT | RIGHT
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:PSEArch
Marker Search Parameters - Marker Search Peak Search Excursion Value
Range: MPNI
Default Value: 0.000000E+000
Parameter Units: dB
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:PSEArch:EXCursion
Marker Search Parameters - Marker Search Peak Search Last Search Type
Range: NA
Default Value: PEAK
Parameter Units: PEAK | LEFT | RIGHT
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:PSEArch?
Marker Search Parameters - Marker Search Peak Search Polarity Value
Range: NA
Default Value: POS
Parameter Units: POSitive | NEGative | BOTH
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:PSEArch:POLarity
Marker Search Parameters - Marker Search Peak Search Threshold Value
Range: MPNF
Default Value: 0.000000E+000
Parameter Units: dB
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MARKer:PSEArch:THREshold
Math Operations - Intertrace Math Operation State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Trace
:CALCulate{1-16}[:SELected]:MATH:INTErtrace[:STATe]
Math Operations - Intertrace Memory Math Operation Type
Range: NA
Default Value: DIV
Parameter Units: ADD | SUBTract | MULTiply | DIVide
Modify Per: Trace
:CALCulate{1-16}[:SELected]:MATH:INTErtrace:FUNCtion
Math Operations - Trace Math Operand Definition
Range: NA
Default Value: TR1, DATA
Parameter Units: TR1 | TR2 | TR3 | TR4 | TR5 | TR6 | TR7 | TR8 | TR9 | TR10 | TR11 | TR12 | TR13 | TR14 | TR15 | TR16
DATA | DMM
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MATH:INTErtrace:OPERand{1-2}:DEFine
Microstrip Configuration - Microstrip Effective Dielectric Value
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:MICrostrip:EFFective
Microstrip Configuration - Microstrip Impedance
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Ohms
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:MICrostrip:Z0
Microstrip Configuration - Microstrip Kit Connector Type
Range: NA
Default Value: Refer to Section 2-17
Parameter Units: USER1 | USER2 | USER3 | USER4 | USER5 | USER6 | USER7 | USER8
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:MICrostrip:PORT{1-2}:CONNector
Microstrip Configuration - Microstrip Kit Type
Range: NA
Default Value: MIL10
Parameter Units: MIL10 | MIL15 | MIL25 | USER1 | USER2 | USER3 | USER4 | USER5 | USER6 | USER7 | USER8
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:MICrostrip:KIT
Microstrip Configuration - Microstrip Substrate Dielectric Value
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:MICrostrip:DIELectric
Microstrip Configuration - Microstrip Substrate Thickness
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Meters
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:MICrostrip:THICKness
Microstrip Configuration - Microstrip Width
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Meters
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:MICrostrip:WIDth
Multiple Source - Multiple Source Band External Module Control State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Multiple Source Band
:SENSe{1-16}:OFFSet:EXTModule[:STATe]
Multiple Source - Multiple Source Band Receiver Frequency Divisor
Range: Depends on the multiple source equation.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:OFFSet{1-50}:RECEiver[:FREQuency]:DIVisor
Multiple Source - Multiple Source Band Receiver Frequency Multiplier
Range: MPNI. Limited by the band equation.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:OFFSet{1-50}:RECEiver[:FREQuency]:MULTiplier
Multiple Source - Multiple Source Band Receiver Offset Frequency
Range: Depends on the multiple source equation.
Default Value: 0.00000000000E+000
Parameter Units: Hertz
Modify Per: Channel
:SENSe{1-16}:OFFSet{1-50}:RCVSource[:FREQuency]:OFFSet
Multiple Source - Multiple Source Band Receiver Offset Frequency
Range: Depends on the multiple source equation.
Default Value: 0.00000000000E+000
Parameter Units: Hertz
Modify Per: Channel
:SENSe{1-16}:OFFSet{1-50}:RECEiver[:FREQuency]:OFFSet
Multiple Source - Multiple Source Band Receiver Source Frequency Divisor
Range: Depends on the multiple source equation.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:OFFSet{1-50}:RCVSource[:FREQuency]:DIVisor
Multiple Source - Multiple Source Band Receiver Source Frequency Multiplier
Range: MPNI. Limited by the band equation.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:OFFSet{1-50}:RCVSource[:FREQuency]:MULTiplier
Multiple Source - Multiple Source Band Start Frequency
Range: Minimum Instrument Frequency to (Maximum Instrument Frequency minus Minimum Frequency Step Size)
Default Value: 7.00000000000E+004
Parameter Units: Hertz
Modify Per: Channel
:SENSe{1-16}:OFFSet{1-50}:STARt
Multiple Source - Multiple Source Control Band Offset Frequency
Range: MPND. Limited by the band equation.
Default Value: 0.00000000000E+000
Parameter Units: Hertz
Modify Per: Channel
:SENSe{1-16}:OFFSet:EXTernal{1-4}[:FREQuency]:OFFSet
Multiple Source - Multiple Source Control Band Receiver Frequency Divisor
Range: MPNI. Limited by the band equation.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:OFFSet:RECEiver[:FREQuency]:DIVisor
Multiple Source - Multiple Source Control Band Receiver Offset Frequency
Range: MPND. Limited by the band equation.
Default Value: 0.00000000000E+000
Parameter Units: Hertz
Modify Per: Channel
:SENSe{1-16}:OFFSet:RECEiver[:FREQuency]:OFFSet
Multiple Source - Multiple Source Control Band Receiver Source Frequency Divisor
Range: MPNI. Limited by the band equation.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:OFFSet:RCVSource[:FREQuency]:DIVisor
Multiple Source - Multiple Source Control Band Receiver Source Frequency Multiplier
Range: MPNI. Limited by the band equation.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:OFFSet:RCVSource[:FREQuency]:MULTiplier
Multiple Source - Multiple Source Control Band Receiver Source Offset Frequency
Range: MPND. Limited by the band equation.
Default Value: 0.00000000000E+000
Parameter Units: Hertz
Modify Per: Channel
:SENSe{1-16}:OFFSet:RCVSource[:FREQuency]:OFFSet
Multiple Source - Multiple Source Control Band Start Frequency
Range: Minimum Instrument Frequency to (Maximum Instrument Frequency minus Minimum Frequency Step Size)
Default Value: 7.00000000000E+004
Parameter Units: Hertz
Modify Per: Channel
:SENSe{1-16}:OFFSet:STARt
Multiple Source - Multiple Source Control Band Stop Frequency
Range: (Minimum Instrument Frequency + Minimum Frequency Step Size) to Maximum Instrument Frequency
Default Value: 1.00000000000E+010
Parameter Units: Hertz
Modify Per: Channel
:SENSe{1-16}:OFFSet:STOP
Multiple Source - Multiple Source Control Band Stop Frequency
Range: (Minimum Instrument Frequency + Minimum Frequency Step Size) to Maximum Instrument Frequency
Default Value: 1.00000000000E+010
Parameter Units: Hertz
Modify Per: Channel
:SENSe{1-16}:OFFSet{1-50}:STOP
Multiple Source - Multiple Source External Module Control State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Multiple Source Band
:SENSe{1-16}:OFFSet{1-50}:EXTModule[:STATe]
Multiple Source - Multiple Source External Source CW Mode State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Multiple Source Band
:SENSe{1-16}:OFFSet{1-50}:EXTernal{1-4}:CW[:STATe]
Multiple Source - Multiple Source Internal Source CW Mode State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Multiple Source Band
:SENSe{1-16}:OFFSet{1-50}:INTernal{1}:CW[:STATe]
Multiple Source - Multiple Source Mode Receiver CW Mode State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Multiple Source Band
:SENSe{1-16}:OFFSet:RECEiver:CW[:STATe]
Multiple Source - Multiple Source Mode Receiver CW Mode State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Multiple Source Band
:SENSe{1-16}:OFFSet:RCVSource:CW[:STATe]
Multiple Source - Multiple Source Mode State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:SENSe{1-16}:OFFSet[:STATe]
Multiple Source - Multiple Source Phase Inversion State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:SENSe{1-16}:OFFSet:PINVersion[:STATe]
Multiple Source - Multiple Source Receiver CW Mode State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Multiple Source Band Per Channel
:SENSe{1-16}:OFFSet{1-50}:RCVSource:CW[:STATe]
Multiple Source - Multiple Source Receiver CW Mode State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Multiple Source Band Per Channel
:SENSe{1-16}:OFFSet{1-50}:RECEiver:CW[:STATe]
Multiple Source - Multiple Source Receiver Frequency Multiplier
Range: MPNI. Limited by the band equation.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:OFFSet:RECEiver[:FREQuency]:MULTiplier
Network Embed/De-Embed - Network Embed/De-Embed Mode
Range: NA
Default Value: EMB
Parameter Units: EMBed | DEEMbed
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork{1-50}:MODe
Network Embed/De-Embed - Network Embedding/De-Embedding State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork[:STATe]
Network Parameters - Embed/De-Embed Mode
Range: NA
Default Value: EMB
Parameter Units: EMBed | DEEMbed
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork:MODe
Network Parameters - Network Swap S2P File Data Flag Mode
Range: NA
Default Value: FALS
Parameter Units: TRUE | FALSe
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork:SWAPs2p
Network Parameters - Network Type
Range: NA
Default Value: LSCP
Parameter Units: LSCP | CSLP | CPLS | LPCS | RS | RP | TLine | S2Pfile
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork{1-50}:TYPe
Network Parameters - R Network Resistance Value
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Ohms
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork{1-50}:R
Network Parameters - R Network Resistance Value
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Ohms
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork:R
Network S2P Parameters - NXN IF Path De-Embedding State
Range: NA
Default Value: 0
Parameter Units: 0 | 1 | OFF | ON
Modify Per: Channel
:CALCulate{1-16}:NXN:IFNavigation:DEEMbedding[:STATe]
Network S2P Parameters - S2P Swap Data Flag
Range: NA
Default Value: FALS
Parameter Units: TRUE | FALSe
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork{1-50}:SWAPs2p
Number of Points - Maximum Number of Points
Range: NA
Default Value: 25000
Parameter Units: 25000 | 100000
Modify Per: Instrument
:SYSTem:POINts:MAXimum
NXN Parameters - NXN Device Length
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: DEV1 | DEV2 | DEV3
Meters
Modify Per: Channel
:CALCulate{1-16}:NXN:LENGth
NXN Parameters - NXN Device Solve
Range: NA
Default Value: DEV1
Parameter Units: DEV1 | DEV2 | DEV3
Modify Per: Channel
:CALCulate{1-16}:NXN:SOLVe
NXN Parameters - NXN IF Path Sweep Direction
Range: NA
Default Value: FOR
Parameter Units: FORward | REVerse
Modify Per: Channel
:CALCulate{1-16}:NXN:IFNavigation:DIRection
Open Configuration - Open Standard C0 (C Zero) Capacitance
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Farads
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:OPEN:C0
Open Configuration - Open Standard C1 Capacitance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:OPEN:C1
Open Configuration - Open Standard C2 Capacitance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:OPEN:C2
Open Configuration - Open Standard C3 Capacitance Coefficient
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:OPEN:C3
Open Configuration - Open Standard Label Input
Range: NA
Default Value: NA
Parameter Units: Alphanumeric Characters
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:OPEN:LABEL
Open Configuration - Open Standard Offset Ohms
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Ohms
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:OPEN:OFFS
Open Configuration - Open Standard Serial Number
Range: NA
Default Value: XXXXXX
Parameter Units: Alphanumeric Characters
Modify Per: Port Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:OPEN:SERial
Port Parameters - Port Connector Type
Range: NA
Default Value: Refer to Section 2-17
Parameter Units: CM2 | CM3 | CMK | CMN | CMS | CMC | CMV | CM1 | CM716 | CNG | CMN75 | CMU1 | CMU2 | CMU3 | CMU4 | CMU5 | CMU6 | CMU7 | CMU8 | CF2 | CF3 | CFK | CFN | CFS | CFC | CFV | CF1 | CF716 | CFN
:SENSe{1-16}:CORRection:COLLect:PORT{1-2}:CONNector
Port Parameters - Port Power Coupling State
Range: NA
Default Value: 1
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:SOURce{1-16}:POWer:PORT:COUPle
Port Parameters - Power Flat Power Correction State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Port Per Channel
:SOURce{1-16}:POWer:PORT{1-2}:CORRection[:STATe]
Port Parameters - Power Level
Range: -3E1 to 3E1
Default Value: Default value depends on model and installed options: <BulletedIndented4>MS4647A with options 51, 61, or 62 = -10 dBm<BulletedIndented4>All other MS4647As = -3 dBm<BulletedIndented4>MS4642A and MS4644A = +5 dBm
Para
:SOURce{1-16}:POWer:PORT{1-2}[:LEVel][:IMMediate][:AMPlitude]
Power Parameters - Port Attenution
Range: 0 to 60 dB dB in 10 dB increments
Default Value: 0
Parameter Units: dB
Modify Per: Port Per Channel
:SOURce{1-16}:POWer:PORT{1-2}:ATTenuation
Power Parameters - Power Slope Mode State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:SOURce{1-16}:POWer:SLOPe[:STATe]
Power Parameters - Power Slope Value
Range: -1E3 to 1E3
Default Value: 0.000000E+000
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SOURce{1-16}:POWer:PORT{1-2}:SLOPe
Power Parameters - Reference Attenuation Value
Range: 0 to 60 dB in 10 dB increments
Default Value: 0
Parameter Units: dB
Modify Per: Port
:SYSTem:PORT{1-2}:REFerence:ATTenuation
Power Parameters - Reference Attenuation Value
Range: 0 to 60 dB in 10 dB increments
Default Value: 0
Parameter Units: dB
Modify Per: Channel
:SOURce{1-16}:POWer:PORT{1-2}:REFerence:ATTenuation
Power Parameters - Test Attenuation Value
Range: 0 to 60 dB in 10 dB increments
Default Value: 0
Parameter Units: dB
Modify Per: Port
:SYSTem:PORT{1-2}:TEST:ATTenuation
Power Sweep Configuration - Power Sweep Effective Single Power
Range: -20 to +5
Default Value: NA
Parameter Units: dBm
Modify Per: Port Per Channel
:SOURce{1-16}:POWer:PORT{1-2}:LINear:SINGle:POWer:EFFective:VALue?
Power Sweep Configuration - Power Sweep Linear Calibration State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Port Per Channel
:SOURce{1-16}:POWer:PORT{1-2}:LINear:CORRection[:STATe]
Power Sweep Configuration - Power Sweep Number of Points
Range: 0 to 60
Default Value: 50
Parameter Units: Unitless Number
Modify Per: Port Per Channel
:SOURce{1-16}:POWer:PORT{1-2}:LINear:POWer:POINts
Power Sweep Configuration - Power Sweep Offset Power
Range: -1E2 to 1E2
Default Value: 0.000000E+000
Parameter Units: dB
Modify Per: Port Per Channel
:SOURce{1-16}:POWer:PORT{1-2}:LINear:POWer:OFFSet
Power Sweep Configuration - Power Sweep Reference Attenuation
Range: 0 to 60 dB in 10 dB increments
Default Value: 0
Parameter Units: dB
Modify Per: Port Per Channel
:SOURce{1-16}:POWer:PORT{1-2}:LINear:REFerence:ATTenuation
Power Sweep Configuration - Power Sweep Single Power
Range: -3E1 to 3E1
Default Value: Default value depends on model and installed options: <BulletedIndented4>MS4647A with options 51, 61, or 62 = -10 dBm<BulletedIndented4>All other MS4647As = -3 dBm<BulletedIndented4>MS4642A and MS4644A = +5 dBm
Para
:SOURce{1-16}:POWer:PORT{1-2}:LINear:SINGle:POWer:VALue
Power Sweep Configuration - Power Sweep Single Power Mode State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Port Per Channel
:SOURce{1-16}:POWer:PORT{1-2}:LINear:SINGle:POWer[:STATe]
Power Sweep Configuration - Power Sweep Start Power
Range: -3E1 to 2.99E1
Default Value: Default value depends on model and installed options: <BulletedIndented4>MS4647A with options 51, 61, or 62 = -10 dBm<BulletedIndented4>All other MS4647As = -3 dBm<BulletedIndented4>MS4642A and MS4644A = +5 dBm
P
:SOURce{1-16}:POWer:PORT{1-2}:LINear:POWer:STARt
Power Sweep Configuration - Power Sweep Start Power Target
Range: MPNF
Default Value: -2.000000E+001
Parameter Units: dBm
Modify Per: Port Per Channel
:SOURce{1-16}:POWer:PORT{1-2}:LINear:CORRection:POWer:STARt
Power Sweep Configuration - Power Sweep Stop Power
Range: -2.99E1 to 3E1
Default Value: Default value depends on model and installed options: <BulletedIndented4>MS4647A with options 51, 61, or 62 = -10 dBm<BulletedIndented4>All other MS4647As = -3 dBm<BulletedIndented4>MS4642A and MS4644A = +5 dBm
P
:SOURce{1-16}:POWer:PORT{1-2}:LINear:POWer:STOP
Power Sweep Configuration - Power Sweep Test Attenuation
Range: 0 to 60 dB in 10 dB increments
Default Value: 0
Parameter Units: dB
Modify Per: Channel
:SOURce{1-16}:POWer:PORT{1-2}:LINear:TEST:ATTenuation
Power Sweep Configuration - Power Test Attenuation
Range: 0 to 60 dB in 10 dB increments
Default Value: 0
Parameter Units: dB
Modify Per: Channel
:SOURce{1-16}:POWer:PORT{1-2}:TEST:ATTenuation
Rear Panel Configuration - Rear Panel Analog Output State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Channel
:CONTrol{1-16}:AOUT[:STATe]
Rear Panel Configuration - Rear Panel Output
Range: NA
Default Value: HOR
Parameter Units: HORizontal | DRIVen | TTL
Modify Per: Channel
:CONTrol{1-16}:AOUT:MODE
Rear Panel Configuration - Rear Panel Output
Range: -10 to +10 Volts
Default Value: 1.000000E+000
Parameter Units: Volts
Modify Per: Channel
:CONTrol{1-16}:AOUT:VOLTage:STOP
Rear Panel Configuration - Rear Panel Output
Range: -10 to +10 Volts
Default Value: 0.000000E+000
Parameter Units: Volts
Modify Per: Channel
:CONTrol{1-16}:AOUT{1-2}:DRIVen:LEV
Rear Panel Configuration - Rear Panel Output
Range: -10 to +10 Volts
Default Value: 0.00000000000E+000
Parameter Units: Volts
Modify Per: Channel
:CONTrol{1-16}:AOUT:VOLTage:STARt
Rear Panel Configuration - Rear Panel Output
Range: NA
Default Value: HIGH
Parameter Units: LOW | HIGH | LPULSE | HPULSE
Modify Per: Channel
:CONTrol{1-16}:AOUT{1-2}:TTL:TYPe
Rear Panel Configuration - Rear Panel Output
Range: 0 to 10 seconds
Default Value: 0.000000E+000
Parameter Units: Seconds
Modify Per: Channel
:CONTrol{1-16}:AOUT:PULSe:WIDth
Reference Plane Configuration - Reference Plane Extension
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Meters
Modify Per: Port
:SENSe{1-16}:CORRection:EXTension:PORT{1-2}
Reference Plane Configuration - Reference Plane Extension Coaxial Line Dielectric Type
Range: NA
Default Value: AIR
Parameter Units: AIR | MICROporous | OTHER | POLYethylene | TEFLON
Modify Per: Channel
:CALCulate{1-16}:REFerence:EXTension:COAXial:DIELectric
Reference Plane Configuration - Reference Plane Extension Coaxial Line Other Dielectric
Range: 1 to 9.99E3
Default Value: 1.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Channel
:CALCulate{1-16}:REFerence:EXTension:COAXial:DIELectric:OTHer
Reference Plane Configuration - Reference Plane Extension Distance
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Meters
Modify Per: Per Port Per Channel
:CALCulate{1-16}:REFerence:EXTension:PORT{1-2}:DISTance
Reference Plane Configuration - Reference Plane Extension Line Type
Range: NA
Default Value: COAX
Parameter Units: COAXial | MICROstrip | NONDISpersive | WAVEguide
Modify Per: Channel
:CALCulate{1-16}:REFerence:EXTension:LINE
Reference Plane Configuration - Reference Plane Extension Loss
Range: -1E3 to +1E3
Default Value: 0.00000000000E+000
Parameter Units: dB
Modify Per: Channel
:CALCulate{1-16}:REFerence:EXTension:PORT{1-2}:LOSS
Reference Plane Configuration - Reference Plane Extension Microstrip Effective Dielectric Value
Range: MPND
Default Value: 6.69000000000E+000
Parameter Units: Unitless Number
Modify Per: Channel
:CALCulate{1-16}:REFerence:EXTension:MICrostrip:EFFective
Reference Plane Configuration - Reference Plane Extension Microstrip Impedance
Range: MPND
Default Value: 5.00000000000E+001
Parameter Units: Ohms
Modify Per: Channel
:CALCulate{1-16}:REFerence:EXTension:MICrostrip:Z0
Reference Plane Configuration - Reference Plane Extension Microstrip Substrate Dielectric Value
Range: 1 to 10
Default Value: 9.96000000000E+000
Parameter Units: Unitless Number
Modify Per: Channel
:CALCulate{1-16}:REFerence:EXTension:MICrostrip:DIELectric
Reference Plane Configuration - Reference Plane Extension Microstrip Substrate Thickness
Range: MPND
Default Value: 2.54000000000E-004
Parameter Units: Meters
Modify Per: Channel
:CALCulate{1-16}:REFerence:EXTension:MICrostrip:THICKness
Reference Plane Configuration - Reference Plane Extension Microstrip Width
Range: MPND
Default Value: 2.38760000000E-004
Parameter Units: Meters
Modify Per: Channel
:CALCulate{1-16}:REFerence:EXTension:MICrostrip:WIDth
Reference Plane Configuration - Reference Plane Extension Phase Offset
Range: -360 to +360
Default Value: 0.000000E+000
Parameter Units: Degrees
Modify Per: Channel
:CALCulate{1-16}:REFerence:EXTension:PORT{1-2}:PHAse
Reference Plane Configuration - Reference Plane Extension Time
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Seconds
Modify Per: Channel
:CALCulate{1-16}:REFerence:EXTension:PORT{1-2}:TIMe
Reference Plane Configuration - Reference Plane Extension Waveguide Cutoff Frequency
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Hertz
Modify Per: Channel
:CALCulate{1-16}:REFerence:EXTension:WAVeguide:FREQuency
Reference Plane Configuration - Reference Plane Extension Waveguide Dielectric Value
Range: MPND
Default Value: 1.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Channel
:CALCulate{1-16}:REFerence:EXTension:WAVeguide:DIELectric
Register Values - Operation Status Enable Register
Range: 0 to 65535
Default Value: NA
Parameter Units: Unitless Number
Modify Per: Instrument
:STATus:OPERation:ENABle
Register Values - Operation Status Register Negative Transition Filter
Range: 0 to 65535
Default Value: NA
Parameter Units: Unitless Number
Modify Per: Instrument
:STATus:OPERation:NTRansition
Register Values - Operation Status Register Positive Transition Filter
Range: 0 to 65535
Default Value: NA
Parameter Units: Unitless Number
Modify Per: Instrument
:STATus:OPERation:PTRansition
Register Values - Questionable Limit Status Enable Register
Range: 0 to 65535
Default Value: NA
Parameter Units: Unitless Number
Modify Per: Instrument
:STATus:QUEStionable:LIMit:ENABle
Register Values - Questionable Limit Status Register Negative Transition Filter
Range: 0 to 65535
Default Value: NA
Parameter Units: Unitless Number
Modify Per: Instrument
:STATus:QUEStionable:LIMit:NTRansition
Register Values - Questionable Limit Status Register Negative Transition Filter
Range: 0 to 65535
Default Value: NA
Parameter Units: Unitless Number
Modify Per: Instrument
:STATus:QUEStionable:NTRansition
Register Values - Questionable Limit Status Register Positive Transition Filter
Range: 0 to 65535
Default Value: NA
Parameter Units: Unitless Number
Modify Per: Instrument
:STATus:QUEStionable:LIMit:PTRansition
Register Values - Questionable Status Enable Register
Range: 0 to 65535
Default Value: NA
Parameter Units: Unitless Number
Modify Per: Instrument
:STATus:QUEStionable:ENABle
Register Values - Questionable Status Register Positive Transition Filter
Range: 0 to 65535
Default Value: NA
Parameter Units: Unitless Number
Modify Per: Instrument
:STATus:QUEStionable:PTRansition
SNP Parameters - SNP Data File Frequency Units
Range: NA
Default Value: GHZ
Parameter Units: HZ | KHZ | MHZ | GHZ
Modify Per: Instrument
:FORMat:SNP:FREQuency
SNP Parameters - SNP Data File Parameter Format
Range: NA
Default Value: REIM
Parameter Units: LINPH | LOGPH | REIM
Modify Per: Instrument
:FORMat:SNP:PARameter
Sweep Parameters - Sweep Delay
Range: NA
Default Value: BEGIN
Parameter Units: BEGIN | LOCK | LOAD | DIP
Modify Per: Channel
:SENSe{1-16}:SWEep:DELay:TYPe
Sweep Parameters - Sweep Delay Time
Range: 0 to 100 Seconds
Default Value: 0.00000000000E+000
Parameter Units: Seconds
Modify Per: Channel
:SENSe{1-16}:SWEep:DELay
Sweep Parameters - Sweep Range Center
Range: 7.0004E4 to 6.9999E10
Default Value: Default value depends on instrument model and installed options: <BulletedIndented4>For MS4647A with option 70 = 3.50000350000E+010 <BulletedIndented4>For MS4644A with option 70 = 2.00000350000E+010 <Bulleted
:SENSe{1-16}:FREQuency:CENTer
Sweep Parameters - Sweep Range Span
Range: Depends on the instrument model and installed options.
Default Value: Depends on the instrument model and installed options.
Parameter Units: Hertz, Meters, or Seconds
Modify Per: Channel
:SENSe{1-16}:FREQuency:SPAN
Sweep Parameters - Sweep Range Start
Range: Minimum Instrument Frequency to (Maximum Instrument Frequency minus Minimum Frequency Step Size)
Default Value: Depends on the instrument installed options.
Parameter Units: Hertz, Meters, or Seconds
Modify Per: Channel
:SENSe{1-16}:FREQuency:STARt
Sweep Parameters - Sweep Range Stop
Range: (Minimum Instrument Frequency + Minimum Frequency Step Size) to Maximum Instrument Frequency
Default Value: Depends on the instrument model and installed options.
Parameter Units: Hertz, Meters, or Seconds
Modify Per: Channel
:SENSe{1-16}:FREQuency:STOP
Sweep Parameters - Sweep Type
Range: NA
Default Value: LIN
Parameter Units: LINear | LOGarithmic | FSEGMent | ISEGMent | POWer | MFGC
Modify Per: Channel
:SENSe{1-16}:SWEep:TYPe
System Parameters - Hardcopy Print Color
Range: NA
Default Value: INV
Parameter Units: NORMal | INVert | BWHITe
Modify Per: Instrument
:HCOPy:IMAGe
System Parameters - Power Up Instrument State
Range: NA
Default Value: LAST
Parameter Units: RESET | LAST | USER
Modify Per: Instrument
:SYSTem:POWerup:TYPe
System Parameters - Reset Zero
Range: NA
Default Value: NA
Parameter Units: NA
Modify Per: Channel
:SYStem:PRESet:ZERo
System Parameters - System Preset
Range: NA
Default Value: RESET
Parameter Units: RESET | USER
Modify Per: Instrument
:SYSTem:PRESet:TYPe
Test Set Parameters - Test Set LO Divisor
Range: MPNI. Limited by the band equation.
Default Value: 8
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:TSET:LO:DIVisor
Test Set Parameters - Test Set LO Multiplier
Range: MPNI. Limited by the band equation.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:TSET:LO:MULTiplier
Test Set Parameters - Test Set RF Multiplier
Range: MPNI. Limited by the band equation.
Default Value: 1
Parameter Units: Unitless Number
Modify Per: Channel
:SENSe{1-16}:TSET:RF:MULTiplier
Test Set Parameters - Test Set Start Frequency
Range: Minimum Instrument Frequency to (Maximum Instrument Frequency minus Minimum Frequency Step Size)
Default Value: 6.70000000000E+010
Parameter Units: Hertz
Modify Per: Channel
:SENSe{1-16}:TSET:FREQuency:STARt
Test Set Parameters - Test Set Stop Frequency
Range: (Minimum Instrument Frequency + Minimum Frequency Step Size) to Maximum Instrument Frequency
Default Value: 1.10000000000E+011
Parameter Units: Hertz
Modify Per: Channel
:SENSe{1-16}:TSET:FREQuency:STOP
Thru-Line Parameters - Thru-Line Impedance on Port Pair
Range: 1E-4 to 1E10
Default Value: Refer to Section 2-17
Parameter Units: Ohms
Modify Per: Channel
:SENSe{1-16}:CORRection:COLLect:PORT{12}:THRU:Z0
Thru-Line Parameters - Thru-Line Label for Port-Pair
Range: NA
Default Value: NA
Parameter Units: Alphanumeric Characters
Modify Per: Port-Pair Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{12}:THRU:LABEL
Thru-Line Parameters - Thru-Line Length on Port Pair
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Meters
Modify Per: Port-Pair Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{12}:THRU:LENGth
Thru-Line Parameters - Thru-Line Loss on Port-Pair
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: dB/mm
Modify Per: Port-Pair Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{12}:THRU:LOSS
Thru-Line Parameters - Thru-Line Reference Frequenc y Loss
Range: MPND
Default Value: Refer to Section 2-17
Parameter Units: Hertz
Modify Per: Port-Pair Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{12}:THRU:FREQuency
Thru-Line Parameters - Thru-Line Serial Number on Port Pair
Range: NA
Default Value: XXXXXX
Parameter Units: Alphanumeric Characters
Modify Per: Port-Pair Per Channel
:SENSe{1-16}:CORRection:COLLect:PORT{12}:THRU:SERial
Thru-Line Parameters - Thru-Line Use Reciprocal Flag Port-Pair State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Port-Pair Per Instrument
:SENSe{1-16}:CORRection:COLLect:PORT{12}:THRU:RECIProcal
Time Domain - Dolph-Chebyshev Gamma Value
Range: 0 to 2E2
Default Value: 4.00000000000E+001
Parameter Units: Unitless Number
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:GATE:DCGamma?
Time Domain Configuration - time domain
Range: -999.99 to 999.99 Seconds
-2.99649E11 to 2.99649E11 Meters
Default Value: 2.00000000000E-009
Parameter Units: Seconds or Meters
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:GATE:STOP
Time Domain Configuration - time domain
Range: NA
Default Value: OFF
Parameter Units: ON | OFF | DISPlay
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:GATE[:STATe]
Time Domain Configuration - Time Domain
Range: NA
Default Value: TIME
Parameter Units: TIME | DISTance
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:UNIt
Time Domain Configuration - Time Domain
Range: 0 to 2E2
Default Value: 4.00000000000E+001
Parameter Units: Unitless Number
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:WINDow:DCGamma
Time Domain Configuration - Time Domain
Range: 0 to E308
Default Value: 5.00000000000E-001
Parameter Units: Unitless Number
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:WINDow:KBBeta
Time Domain Configuration - Time Domain
Range: NA
Default Value: FREQ
Parameter Units: FREQuency | FREQGATE | LOWpass | BANDpass
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:TYPe
Time Domain Configuration - Time Domain Anti-Gating State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Trace
:CALCulate{1-16}[:SELected]:TRANsform:TIME:GATE:NOTch[:STATe]
Time Domain Configuration - Time Domain Center
Range: -999.999 to 999.999 Seconds
-2.99649E11 to 2.99649E11 Meters
Default Value: 1.50000000000E-009
Parameter Units: Seconds or Meters
Modify Per: Trace
:CALCulate{1-16}[:SELected]:TRANsform:TIME:CENTer
Time Domain Configuration - Time Domain DC Term
Range: NA
Default Value: AUTO
Parameter Units: AUTO | OTHER
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:DCTerm
Time Domain Configuration - Time Domain DC Term Other
Range: 0 to 5E3
Default Value: 0.00000000000E+000
Parameter Units: Ohms
Modify Per: Trace
:CALCulate{1-16}[:SELected]:TRANsform:TIME:DCTerm:OTHer
Time Domain Configuration - Time Domain Dolph-Chebyshev Gamma
Range: 0 to 2E2
Default Value: 4.00000000000E+001
Parameter Units: Depends on display type
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:GATE:DCGamma
Time Domain Configuration - Time Domain Extrapolation Method
Range: NA
Default Value: PHASE
Parameter Units: MAGPHase | PHASE | USER
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:EXTrapolate
Time Domain Configuration - Time Domain Gate Center Value
Range: -999.99 to 999.99 Seconds
-2.99649E11 to 2.99649E11 Meters
Default Value: 1.50000000000E-009
Parameter Units: Seconds or Meters
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:GATE:CENTer
Time Domain Configuration - Time Domain Gate Shape
Range: NA
Default Value: NOM
Parameter Units: MINimum | NOMinal | WIDE | MAXimum | DCHebyshev | KBEssel
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:GATE:SHAPe
Time Domain Configuration - Time Domain Gate Span
Range: -999.99 to 999.99 Seconds
-2.99649E11 to 2.99649E11 Meters
Default Value: 1.00000000000E-009
Parameter Units: Seconds or Meters
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:GATE:SPAN
Time Domain Configuration - Time Domain Kaiser-Bessel Beta
Range: 0 to E308
Default Value: 5.00000000000E-001
Parameter Units: Unitless Number
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:GATE:KBBeta
Time Domain Configuration - Time Domain Start Gate
Range: -999.99 to 999.99 Seconds
-2.99649E11 to 2.99649E11 Meters
Default Value: 1.00000000000E-009
Parameter Units: Seconds or Meters
Modify Per: Trace
:CALCulate{1-16}[:SELected]:TRANsform:TIME:GATE:STARt
Time Domain Configuration - Time Domain Time Zoom State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Trace
:CALCulate{1-16}[:SELected]:TRANsform:TIME:ZOOM[:STATe]
Time Domain Configuration - Time Domain Transform Response
Range: NA
Default Value: IMP
Parameter Units: IMPulse | STEP
Modify Per: Trace
:CALCulate{1-16}[:SELected]:TRANsform:TIME:RESPonse
Time Domain Configuration - Time Domain Trip Length Transform
Range: NA
Default Value: AUTO
Parameter Units: ONEway | ROUNDtrip | AUTO
Modify Per: Trace
:CALCulate{1-16}[:SELected]:TRANsform:TIME:TRIP
Time Domain Configuration - Time Window Shape
Range: NA
Default Value: NOM
Parameter Units: RECTangular | NOMinal | LOWsidelobe | MINsidelobe | DCHebyshev | KBEssel
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:WINDow:SHAPe
Time Domain Configuration - Time Zoom Impulses
Range: 0 to 2147483648
Default Value: 0
Parameter Units: Unitless Number
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:ZOOM:IMPulses
Time Domain Configuration - Time/Distance Span
Range: -999.99 to 999.99 Seconds
-2.99649E11 to 2.99649E11 Meters
Default Value: 5.00000000000E-009
Parameter Units: Seconds or Meters
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:SPAN
Time Domain Configuration - Time/Distance Start
Range: -999.99 to 999.99 Seconds
-2.99649E11 to 2.99649E11 Meters
Default Value: -1.00000000000E-009
Parameter Units: Seconds or Meters
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:STARt
Time Domain Configuration - Time/Distance Stop
Range: -999.99 to 999.99 Seconds
-2.99649E11 to 2.99649E11 Meters
Default Value: 4.00000000000E-009
Parameter Units: Seconds or Meters
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:STOP
Time Domain Parameters - Time Domain Center Time/Distance
Range: -999.99 to 999.99 Seconds
-2.99649E11 to 2.99649E11 Meters
Default Value: 1.50000000000E-009
Parameter Units: Seconds or Meters
Modify Per: Channel
:CALCulate{1-16}[:SELected]:TRANsform:TIME:GATE:CENTer?
T-Line Network Parameters - T-Line
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Hertz
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork:FREQuency
T-Line Network Parameters - T-Line
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Meters
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork:LENGth
T-Line Network Parameters - T-Line
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: dB/mm
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork:LOSS
T-Line Network Parameters - T-Line Network Impedance Value
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Ohms
Modify Per: Indicated Network per Channel
:CALCulate{1-16}:FSIMulator:NETWork{1-50}:Z0
T-Line Network Parameters - T-Line Network Impedance Value
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Ohms
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork:Z0
T-Line Network Parameters - T-Line Network Line Length Value
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Meters
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork{1-50}:LENGth
T-Line Network Parameters - T-Line Network Line Loss Frequency Value
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Hertz
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork{1-50}:FREQuency
T-Line Network Parameters - T-Line Network Line Loss Value
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: dB/mm
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork{1-50}:LOSS
T-Line Network Parameters - T-Line Network Other Dielectric Value
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork:DIELectric
T-Line Network Parameters - T-Line Network Other Dielectric Value
Range: MPND
Default Value: 0.00000000000E+000
Parameter Units: Unitless Number
Modify Per: Channel
:CALCulate{1-16}:FSIMulator:NETWork{1-50}:DIELectric
Trace Parameters - Display Color Data Trace Inverted
Range: 0 to 255
Default Value: 255,255,0
Parameter Units: Integers between 0 and 255
Modify Per: Trace
:DISPlay:COLor:INVert:TRACe{1-16}:DATA
Trace Parameters - Display Data Trace Normal Color Set
Range: 0 to 255
Default Value: 255,255,0
Parameter Units: Integers between 0 and 255
Modify Per: Trace
:DISPlay:COLor:NORMal:TRACe{1-16}:DATA
Trace Parameters - Display Memory Trace Color Normal
Range: 0 to 255
Default Value: 175,143,47
Parameter Units: Integers between 0 and 255
Modify Per: Trace
:DISPlay:COLor:NORMal:TRACe{1-16}:MEMory
Trace Parameters - Display Memory Trace Inverted Color
Range: 0 to 255
Default Value: 175,143,47
Parameter Units: Integers between 0 and 255
Modify Per: Trace
:DISPlay:COLor:INVert:TRACe{1-16}:MEMory
Trace Parameters - Group Delay Aperture
Range: 0 to 2E1
Default Value: 0.000000E+000
Parameter Units: Percent
Modify Per: Trace
:CALCulate{1-16}[:SELected]:GDELay:APERture
Trace Parameters - Measurement Parameters
Range: NA
Default Value: S11 for PARM1
S12 for PARM2
S21 for PARM3
S22 for PARM4
S11 for all others.
Parameter Units: S11 | S12 | S21 | S22 | USR | EXT1 | EXT2
A1 | A2 | B1 | B
:CALCulate{1-16}:PARameter{1-16}:DEFine
Trace Parameters - Parameter Conversion Mode
Range: NA
Default Value: INV
Parameter Units: ZREFlection | ZTRansmit | YREFlection | YTRansmit | INVersion
Modify Per: Trace
:CALCulate{1-16}[:SELected]:CONVersion:FUNCtion
Trace Parameters - Parameter Conversion State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Trace
:CALCulate{1-16}[:SELected]:CONVersion[:STATe]
Trace Parameters - Reference Level Bottom Display
Range: -9.999E2 to +9.999E2
Default Value: 0.00
Parameter Units: Depends on display type
Modify Per: Trace
:DISPlay:WINDow{1-16}:TRACe{1-16}:Y:RLEV2
Trace Parameters - Scale Auto Scale
Range: NA
Default Value: NA
Parameter Units: NA
Modify Per: Instrument
:DISPlay:Y:AUTO
Trace Parameters - Scale Auto Scale
Range: NA
Default Value: NA
Parameter Units: NA
Modify Per: Trace
:DISPlay:WINDow{1-16}:TRACe{1-16}:Y:AUTO
Trace Parameters - Scale Auto Scale
Range: NA
Default Value: NA
Parameter Units: NA
Modify Per: Channel
:DISPlay:WINDow{1-16}:Y:AUTO
Trace Parameters - Scale Bottom Display Per-Division Value
Range: 1E-5 to 1E9
Default Value: 1.000000E+001
Parameter Units: Hertz, Meters, Seconds, dB
Modify Per: Trace
:DISPlay:WINDow{1-16}:TRACe{1-16}:Y:PDIV2
Trace Parameters - Scale Bottom Display Reference Line Position
Range: Minimum Reference Line Postion = 0, Maximum Reference Line Position = Maximum Number of Divisions set by :DISPlay:Y:NDIVisions \<NRf\>
Default Value: 5
Parameter Units: Depends on display type
Modify Per: Trace
:DISPlay:WINDow{1-16}:TRACe{1-16}:Y:RPOS2
Trace Parameters - Scale Rectilinear Vertical Divisions
Range: 4 to 30
Default Value: 10
Parameter Units: Unitless Number
Modify Per: Channel
:DISPlay:WINDow:Y:NDIVisions
Trace Parameters - Scale Rectilinear Vertical Divisions
Range: NA
Default Value: NA
Parameter Units: NA
Modify Per: Channel
:DISPlay:Y:NDIVisions
Trace Parameters - Scale Top Display Per-Division Value
Range: 1E-5 to 1E9 for most display types. 1E-3 to 1E3 for Log Mag display type. See Table 2-8.
Default Value: 1.000000E+001
Parameter Units: Hertz, Meters, or Seconds
Modify Per: Trace
:DISPlay:WINDow{1-16}:TRACe{1-16}:Y:PDIV
Trace Parameters - Smith Chart Impedance
Range: MPNF
Default Value: 5.000000E+001
Parameter Units: Ohms
Modify Per: Trace
:CALCulate{1-16}[:SELected]:SMITh:IMPedance
Trace Parameters - Smith Chart Wrap Offset
Range: -3.6E2 to 3.6E2
Default Value: 0.000000E+000
Parameter Units: Unitless Number
Modify Per: Trace
:CALCulate{1-16}[:SELected]:SMITh:WRAP
Trace Parameters - Smoothing Aperature Percentage
Range: 0 to 100
Default Value: 0.000000E+000
Parameter Units: Percent
Modify Per: Trace
:CALCulate{1-16}[:SELected]:SMOothing:APERture
Trace Parameters - Smoothing State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Trace
:CALCulate{1-16}[:SELected]:SMOothing[:STATe]
Trace Parameters - Trace
Range: -9.999E2 to +9.999E2
Default Value: 0.00
Parameter Units: Depends on display type
Modify Per: Trace
:DISPlay:WINDow{1-16}:TRACe{1-16}:Y:RLEV
Trace Parameters - Trace Active Set
Range: NA
Default Value: 1
Parameter Units: NA
Modify Per: Trace
:CALCulate{1-16}:PARameter{1-16}:SELect
Trace Parameters - Trace Display Format
Range: NA
Default Value: SMIT
Parameter Units: GDELay | IMAGinary | LINPHase | LOGPHase | MLINear | MLOGarithmic | PHASe | PLINear | PLINCOMPlex | PLOGarithmic | PLOGCOMPlex | PWRIn | PWROut | REAL|REIMaginary| SADCOMplex | SADLINear | SADLOGarithmi
:CALCulate{1-16}[:SELected]:FORMat
Trace Parameters - Trace Format
Range: NA
Default Value: SMIT for PAR1 and PAR4
LOGPH for PAR2 and PAR3
MLOG for all others.
Parameter Units: GDELay | IMAGinary | LINPHase | LOGPHase | MLINear | MLOGarithmic | PHASe | PLINear | PLINCOMPlex | PLOGarithmic | PL
:CALCulate{1-16}:PARameter{1-16}:FORMat
Trace Parameters - Trace Layout
Range: NA
Default Value: R2C2
Parameter Units: R1C1 | R1C2 | R2C1 | R1C3 | R3C1 | R2C2C1 | R2C1C2 | C2R2R1 | C2R1R2 | R1C4 | R4C1 | R2C2 | R2C3 | R3C2 | R2C4 | R4C2 | R3C3 | R5C2 | R2C5 | R4C3 | R3C4 | R4C4
Modify Per: Trace
:DISPlay:WINDow{1-16}:SPLit
Trace Parameters - Trace Memory Display
Range: NA
Default Value: DATA
Parameter Units: DATA | MEM | DTM | DMM | OFF
Modify Per: Trace
:CALCulate{1-16}[:SELected]:MATH:DISPlay?
Trace Parameters - Trace Memory Display Operation Type
Range: NA
Default Value: DATA
Parameter Units: DATA | MEM | DTM | DMM | OFF
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MATH:DISPlay
Trace Parameters - Trace Memory Math Operation Type
Range: NA
Default Value: DIV
Parameter Units: ADD | SUBTract | MULTiply | DIVide
Modify Per: Channel
:CALCulate{1-16}[:SELected]:MATH:FUNCtion
Trace Parameters - Trace Phase Offset
Range: -3.6E2 to 3.6E2
Default Value: 0.000000E+000
Parameter Units: Degrees
Modify Per: Trace
:DISPlay:WINDow{1-16}:TRACe{1-16}:Y:PHOFF
Trace Parameters - Trace Polar Chart Type
Range: NA
Default Value: MAGP
Parameter Units: MAGPhase | MAGSweep
Modify Per: Channel
:CALCulate{1-16}:POLar:CHARt
Trace Parameters - Trace Polar Start Angle
Range: -3.6E2 to 3.6E2
Default Value: 0.00000000000E+000
Parameter Units: Degrees
Modify Per: Channel Per Trace
:CALCulate{1-16}:POLar:ANGLe:STARt
Trace Parameters - Trace Polar Stop Angle
Range: -3.6E2 to 3.6E2
Default Value:
Parameter Units: Degrees
Modify Per: Channel
:CALCulate{1-16}:POLar:ANGLe:STOP
Trace Parameters - Trace Reference Line
Range: Minimum Reference Line Postion = 0, Maximum Reference Line Position = Maximum Number of Divisions set by :DISPlay:Y:NDIVisions \<NRf\>
Default Value: 5
Parameter Units: Depends on display type
Modify Per: Channel
:DISPlay:WINDow{1-16}:TRACe{1-16}:Y:RPOS
Trace Parameters - Traces Per Channel Number
Range: 1 to 16
Default Value: 4
Parameter Units: Unitless Number
Modify Per: Channel
:CALCulate{1-16}:PARameter:COUNt
Trigger Parameters - Hold Function All Channels
Range: NA
Default Value: NA
Parameter Units: CONTinuous | HOLD | SINGle
Modify Per: Instrument
:SENSe:HOLD:FUNCtion
Trigger Parameters - Hold Function Type
Range: NA
Default Value: NA
Parameter Units: CONTinuous | HOLD | SINGle
Modify Per: Channel
:SENSe{1-16}:HOLD:FUNCtion
Trigger Parameters - Trigger Delay Time External
Range: 0 to 10 seconds with Minimum Step Size = 1 Nanosecond (ns). If delay is set below 1 ns, the instrument returns 0 (zero) seconds.
Default Value: 0.000000E+000
Parameter Units: Seconds
Modify Per: Instrument
:TRIGger[:SEQuence]:EXTernal:DELay
Trigger Parameters - Trigger External Handshake State
Range: NA
Default Value: 0
Parameter Units: 1 | 0 | ON | OFF
Modify Per: Instrument
:TRIGger[:SEQuence]:EXTernal:HANDshake[:STATe]
Trigger Parameters - Trigger External Leading/Trailing Edge
Range: NA
Default Value: POS
Parameter Units: POSitive | NEGative
Modify Per: Instrument
:TRIGger[:SEQuence]:EXTernal:EDGe
Trigger Parameters - Trigger External Type
Range: NA
Default Value: CHAN
Parameter Units: POINt | SWEep | CHANnel | ALL
Modify Per: Instrument
:TRIGger[:SEQuence]:EXTernal:TYPe
Trigger Parameters - Trigger Manual Type
Range: NA
Default Value: CHAN
Parameter Units: POINt | SWEep | CHANnel | ALL
Modify Per: Instrument
:TRIGger[:SEQuence]:MANual:TYPe
Trigger Parameters - Trigger Remote Type
Range: NA
Default Value: CHAN
Parameter Units: POINt | SWEep | CHANnel | ALL
Modify Per: Instrument
:TRIGger[:SEQuence]:REMote:TYPe
Trigger Parameters - Trigger Sweep Measurement
Range: NA
Default Value: AUTO
Parameter Units: AUTO | MANual | EXTernal | REMote
Modify Per: Instrument
:TRIGger[:SEQuence]:SOURce