Backhaul Analyzer for Anritsu’s RF and Microwave Handheld Instruments : E1 Analyzer (Option 52 or 55) : Rx Signal Measurement Procedure
  
Rx Signal Measurement Procedure
1. Press the Measurements main menu key to activate the Measurements menu.
2. Press the Rx Signal submenu key to activate Rx Signal measurement.
3. Press the Start/Stop main menu key to start and stop the measurement.
Rx Signal Measurement
Out‑of‑service Measurements
Out‑of‑service measurements are performed when the E1 circuit is not in-service or is inactive. Typically these tests are done during initial installation, during circuit acceptance by the wireless service provider, or when the results of the in‑service measurements indicate errors. These measurements provide detailed information on the E1 circuit.
Out‑of‑service testing is performed using end‑to‑end testing, which requires a technician and an E1 tester at each end of the circuit, or by establishing a loopback at the remote end of the circuit.
The following measurements are used to check the E1 performance during out‑of‑service testing:
Vpp
Carrier Frequency
CRC Errors
Frame Sync
Pattern Sync
E‑Bits