Backhaul Analyzer for Anritsu’s RF and Microwave Handheld Instruments : OC-3c Analyzer (Option 58) : Testing
  
Testing
Warning
NEVER look directly into the BTS Master optical connector or the end of a connected cable. LASER light may enter the eye and cause injury. In addition, some Small Form Pluggable (SFP) modules output high-power optical signals.
To prevent damage to connected equipment, confirm that any connected photo-receiver will not be saturated. Anritsu accepts no responsibility for damage caused to connected devices.
1. Attach the optical line to the OC3c/STM-1 connector on the connector panel of the instrument.
2. Press the LASER On/Off main menu key to turn on the LASER. The LASER On/Off status is located at the top of the left status column.
3. Press the Start/Stop main menu key to begin testing. The measurement On/Off status is located at the bottom of the left status column. Previous measurement results in either the Rx Signal table or Event List are cleared. New measurement results will be viewed in the yellow Pass/Fail display along with the selected measurement in the SONET menu. To clear any previously acquired data in the Pass/Fail indicator window, press the Clear History submenu key in the Measurements menu.
Rx Signal Summary