:SENSe Subsystem
The commands in this subsystem relate to device‑specific parameters, not signal‑oriented parameters.
:[SENSe:]:DTPMeas:AVERage:TYPE :[SENSe:]:DTPMeas:AVERage:TYPE?
Title
DTP Trace Mode
Description
Sets and queries DTP trace mode
Parameter
NONE = normal
MAXimum = max trace hold
Default Value:
None – Returns error
Example
To set DTP trace mode to normal:
:SENSe:DTPMeas:AVERage:TYPE NONE
Front Panel Access
Sweep/Setup , Normal -> A / Max Hold -> A
:[SENSe:]:DTPMeas:DISPlay:TOP|BOTTom :[SENSe:]:DTPMeas:DISPlay:TOP?|BOTTom?
Title
DTP Display Top and Bottom
Description
Sets and queries DTP display magnitude
Parameter
top/bottom magnitude
Default Value:
None – Returns error
Example
To set the DTP display top to 10 dB:
:SENSe:DTPMeas:DISPlay:TOP 10.0
Front Panel Access
Amplitude , Top/Bottom
:[SENSe:]:DTPMeas:FREQuency:BANd :[SENSe:]:DTPMeas:FREQuency:BANd?
Title
DTP Preset State
Description
Sets and queries current DTP preset state. This sets up various parameters to some predetermined values.
Parameter
Parameter
Description
PIM Master
PCS_20W
PCS band with 20 watts output power
MW8219A
PCS_40W
PCS band with 40 watts output power
MW8219A
PCS_AWS_20W
PCS/AWS band with 20 watts output power
MW8219A
PCS_AWS_40W
PCS/AWS band with 40 watts output power
MW8219A
E_GSM_900_20W
E‑GSM band with 20 watts output power
MW8209A
E_GSM_900_40W
E‑GSM band with 40 watts output power
MW8209A
US_CELL_850_20W
US Cellular band with 20 watts output power
MW8208A
US_CELL_850_40W
US Cellular band with 40 watts output power
MW8208A
Default Value:
None – Returns error
Example
To set the preset state to PCS_20W:
:SENSe:DTPMeas:FREQuency:BANd PCS_20W
Front Panel Access
Freq/Dist , DTP Aid , Preset State
:[SENSe:]:DTPMeas:FREQuency:F1|F2:STARt|F2:STOP :[SENSe:]:DTPMeas:FREQuency:F1|F2:STARt|F2:STOP?
Title
PIM Master Frequency Setup
Description
Sets the PIM Master LO frequencies, calculates the IMx Order frequency, and sets the Anritsu handheld instrument for the corresponding IMx frequency.
Parameter
MW8208A:
869 MHz to 894 MHz
MW8209A:
925 MHz to 960 MHz
MW8219A:
1930 MHz to 1990 MHz
2110 MHz to 2155 MHz
(Frequency ranges are valid ranges. Frequency input in Hz.)
Default Unit:
Hz
Range:
PIM Master Model
MW8208A:
869 MHz to 894 MHz
MW8209A:
925 MHz to 960 MHz
MW8219A:
1930 MHz to 1990 MHz
2110 MHz to 2155 MHz
Example
To set the PIM Test frequency F2 for 1990 MHz:
:SENSe:DTPMeas:FREQuency:F2 1990000000
Sets the measurement receiver center frequency to the 5th order IMD.
Front Panel Access
Freq , Carrier F1|Carrier F2
:[SENSe:]:DTPMeas:MEASure :[SENSe:]:DTPMeas:MEASure?
Title
DTP Measurement
Description
Sets and queries DTP measurement
Parameter
0 = Stop measurement
1 = Start measurement
Default Value:
None – Returns error
Example
To start DTP measurement:
:SENSe:DTPMeas:MEASure 1
Front Panel Access
Measurements , Test
:[SENSe:]:DTPMeas:OUTput:POWer :[SENSe:]:DTPMeas:OUTput:POWer?
Title
DTP Output Power
Description
Sets the deliverable output from the PIM Analyzer to the system under test.
Parameter
0 = 40 Watts
1 = 30 Watts
2 = 20 Watts
Default Value:
None – Returns error
Range:
0, 1, or 2
Example
To set the PIM Output Power:
:SENSe:DTPMeas:OUTput:POWer 0
Sets the DTP output to 40 Watts.
Front Panel Access
Setup , Output Power
:[SENSe:]:DTPMeas:TEST:DURation :[SENSe:]:DTPMeas:TEST:DURation?
Title
DTP Test Duration
Description
Sets and queries DTP measurement time duration.
Parameter
Time in second
Default Value:
None – Returns error
Example
To set DTP measurement to 60 seconds:
:SENSe:DTPMeas:TEST:DURation 60
Front Panel Access
Measurements , Test
:[SENSe:]PIManalyzer:AUTorange OFF|ON|0|1 :[SENSe:]PIManalyzer:AUTorange?
Title
Auto Range Setup
Description
Sets the Anritsu handheld instrument to auto range the amplitude of the PIM signal received from the PIM Master. There is an initial 1 second measurement of the PIM power so the Anritsu handheld instrument can adjust reference level and span appropriately. This is followed by the actual measurement at the pre described test duration. The query part of the command returns the value of the current Auto Range setup.
Default Value
0
Range
0|Off, Auto Ranging is OFF 1|ON, Auto Ranging is ON
Example
To set the Anritsu handheld instrument for Auto range:
:SENSe:PIManalyzer:AUTorange 1
Front Panel Access
Amplitude , Auto Range
:[SENSe:]PIManalyzer:FREQuency:F1|F2 :[SENSe:]PIManalyzer:FREQuency:F1|F2?
Title
PIM Master Frequency Setup
Description
Sets the PIM Master LO frequencies, calculates the IMx Order frequency and sets the Anritsu handheld instrument for the corresponding IMx frequency.
Parameter
MW8208A:
869 MHz to 894 MHz
MW8209A:
925 MHz to 960 MHz
MW8219A:
1930 MHz to 1990 MHz
2110 MHz to 2155 MHz
(Frequency ranges are valid ranges. Frequency input in Hz.)
Default Unit:
Hz
Range:
PIM Master Model
MW8208A:
869 MHz to 894 MHz
MW8209A:
925 MHz to 960 MHz
MW8219A:
1930 MHz to 1990 MHz
2110 MHz to 2155 MHz
Example
To set the PIM Test frequency F2 for 1990 MHz:
:SENSe:PIManalyzer:FREQuency:F2 1990000000
Front Panel Access
Freq , Carrier F1 |Carrier F2
:[SENSe:]PIManalyzer:IMD:ORDer :[SENSe:]PIManalyzer:IMD:ORDer?
Title
Measurement Receiver / PIM Master Inter‑Modulation Distortion (IMD) Order Setup
Description
Sets the measurement receiver center frequency to receive one of the following IMDs from the PIM Master measurement system: 3/5/7. The query command returns the possible strings “3rd”, “5th” and “7th” depending on the current selection of IMD Order.
Default Value
3
Range: 3, 5 and 7 are the only acceptable values.
Example
To set the measurement receiver for the 5th order IMD:
:SENSe:PIManalyzer:IMD:ORDer 5
Sets the measurement receiver center frequency to the 5th order IMD.
Front Panel Access
Freq , Intermod Order
:[SENSe:]PIManalyzer:MEASure:STATus?
Title
Measurement Receiver/ PIM Master Current Measurement Status
Description
The query returns the current measurement status of the measurement receiver/PIM Analyzer measurement system. Since the measurement system can run for 60 seconds, the query serves to indicate if the measurement is still in process.
Range
0, Measurement is OFF 1, Measurement is ON
:[SENSe:]PIManalyzer:MEASure:VALue?
Title
Measurement Receiver Measured Value From PIM Master Measurement Setup
Description
The query returns an inter modulation measured value in both dBc and dBm.
Parameter:
<amplitude>
Default Unit
dBc/dBm
Front Panel Access
N/A. Inter modulation distortion value is displayed in the lower measurement box as “PIM =”.
:[SENSe:]PIManalyzer:MODe :[SENSe:]PIManalyzer:MODe?
Title
PIM Analyzer Mode, Set or Request
Description
Puts the system into either PIM measurement mode or Distance‑to‑PIM™ measurement mode. The query reports the current system mode.
Parameter
None
Query Response
PIM or DTP
Default Value
None
Example
To set the PIM Analyzer mode to measure Distance‑to‑PIM™:
:SENSe:PIManalyzer:MODe DTP
To query the state of the PIM Analyzer system:
:SENSe:PIManalyzer:MODe?
Front Panel Access
Measurements , PIM Measurements , Distance‑to‑PIM
:[SENSe:]PIManalyzer:OUTput:POWer :[SENSe:]PIManalyzer:OUTput:POWer?
Title
PIM Analyzer Output Power
Description
Sets the deliverable output from the PIM Analyzer to the system under test.
Parameter
0 = 40 Watts
1 = 30 Watts
2 = 20 Watts
Default Value
2 (20 Watts)
Range
0, 1 or 2
Example
To set the PIM Output Power:
:SENSe:PIManalyzer:OUTput:POWer 0
Sets the PIM output to 40 Watts.
Front Panel Access
Setup , Output Power
:[SENSe:]PIManalyzer:TESt:DURation :[SENSe:]PIManalyzer:TESt:DURation?
Title
PIM Test Measurement Test Duration
Description
Sets the amount of time in seconds the PIM Master will be on for intermodulation distortion measurements.
Parameter
<time>
Default Value
20
Default Unit
Seconds
Range
1.0 to 60.0 seconds
Example
To set the test duration time to 5 seconds:
:SENSe:PIManalyzer:TESt:DURation 5.0
Front Panel Access
Setup , Test Duration
1-800-ANRITSU
10450-00017, Rev. D