This set of commands returns the most recent measurement data of the active measurement. They will not switch to another measurement.
To make a new measurement, use the INITiate command. To get new measurement data, use the READ or MEASure query commands.
:FETCh:DEMod:CCPData?
Title
Fetch Control Power Data
Description
Returns the most recent Control Channel Power measurement numeric results.
Data is returned as 24 comma-delimited values: RS_POWER, PSS_POWER, SSS_POWER, BCH_POWER, CFI_POWER, RS_TOTAL_POWER, PSS_TOTAL_POWER, SSS_TOTAL_POWER, BCH_TOTAL_POWER, CFI_TOTAL_POWER, TOTAL_POWER, TOTAL_CHANNEL_POWER
Front Panel Access
Measurements, Modulation, Control Channel Power
:FETCh:DEMod:CONStln?
Title
Fetch Constellation
Description
Returns the constellation measurement numeric results of the demodulated data symbol over one sub-frame measurement.
Data is returned as 9 comma-delimited values: EVM (rms) in %, EVM (pk) in %, Ref Signal (RS) Power in dBm, Sync Signal (SS) Power in dBm, Carrier Frequency in MHz, Freq Error in Hz, Freq Error in ppm, the Cell ID, and the number of measurements used in the frequency error average. “--” is returned for each data that is not valid at that instance.
If frequency error average is on, then the response string includes the averaged frequency error value.
Front Panel Access
Measurements, Modulation, Constellation
:FETCh:OTA:MAPping?
Title
Fetch OTA Coverage Mapping
Description
Returns the most recent Coverage Mapping measurement results.
Data is returned as 2 comma-delimited values: Channel Power in dBm and Occupied bandwidth measurement in MHz. “--” is returned for each data that is not valid at that instance.
Data is returned as 6 sets of comma-delimited values. Each set as follows: Cell ID, Group ID, Sector ID, S-SS Power, RSRP, RSRQ, and SINR.
Following the six sets of data is a final value for the Dominance.“--” is returned for each data that is not valid at that instance.
Front Panel Access
Measurements, Over-the-Air, Mapping
:FETCh:OTA:SCANner?
Title
Fetch OTA Scanner
Description
Returns the most recent OTA Scanner measurement results.
Data is returned as 6 sets of comma-delimited values. Each set as follows: Cell ID, Group ID, Sector ID, S-SS Power, RSRP, RSRQ, and SINR
Following the six sets of data is a final value for the Dominance. “--” is returned for each data that is not valid at that instance.
Front Panel Access
Measurements, Over-the-Air, Scanner
:FETCh:OTA:TXTEst?
Title
Fetch OTA Tx Test
Description
Returns the most recent OTA Tx Text measurement results.
Data is returned as 3 sets of comma-delimited values. Each set as follows: Cell ID, Group ID, Sector ID, S-SS Power, RSRP, RSRQ, and SINR
Following the six sets of data is and addition set of four numbers: Dominance, Antenna count, Average Power, Delta Power. “--” is returned for each data that is not valid at that instance.
Front Panel Access
Measurements, Over-the-Air, Tx Test
:FETCh:RF:ACLR?
Title
Fetch Adjacent Channel Leakage Ratio
Description
Returns the most recent adjacent channel leakage ratio measurement results. If the instrument is sweeping, it will not return until the sweep is complete. Refer to :READ:RF:ACLR? for a description of the returned data.
Default Unit
dBm
Front Panel Access
Measurements, RF, ACLR
:FETCh:RF:SEM?
Title
Fetch Spectral Emission Mask
Description
Returns Spectral Emission Mask measurement results (Pass or Fail).
Front Panel Access
Measurements, RF, Spectral Emission Mask
:FETCh:RF:SPECtrum?
Title
Fetch RF Spectrum
Description
Returns the most recent RF Spectrum measurement results. Data is returned as 2 comma-delimited values: Channel Power in dBm and Occupied bandwidth measurement in MHz. “--” is returned for each data that is not valid at that instance.
Front Panel Access
Measurements, RF, Channel Spectrum
:FETCh:SUMMary?
Title
Fetch Summary
Description
Returns the values displayed in a Summary measurement view. If the current display is not a summary screen, then the return value is ‘N/A’. The return value is a comma separated list of the values displayed on the screen, in the order they are displayed from top to bottom. The list is preceded by the name of the summary view; either “LTE Summary”, “RF Summary” or “Modulation Summary”.
If frequency Error is a parameter in the summary results, then the returned value will be current displayed value averaged over an indeterminate number of previous measurements. Averaged value only returned if Frequency Error Average Count > 1. The maximum number of averaged values will be the value setting for Frequency Error Average Count.