S331E, S332E, S361E, S362E Site Master™MS2711E, MS2712E, MS2713E Spectrum Master™MT8212E, MT8213E Cell Master™ Programming Manual : AM/FM/PM Commands : :MMEMory Subsystem
 
:MMEMory Subsystem
The Mass Memory subsystem contains functions that provide access to the instrument’s setup and data storage.
:MMEMory:DELete <filename>
Title
Delete Setup/Measurement
Description:
Removes a file specified by <filename> from the current mass storage device. <filename> should be enclosed in either single quotes (‘ ’) or double quotes (“ ”) and it must include the file extension. Use the command MMEMory:MSIS to set the current file location.
Parameter:
<filename>
Related Command:
:MMEMory:STORE:STATe
:MMEMory:STORe:TRACe
:MMEMory:MSIS INTernal|USB
Front Panel Access
Shift‑7 (File), Delete, Delete Selected File
:MMEMory:LOAD:STATe <integer>,<filename>
Title
Recall Setup
Description:
Recalls a previously stored instrument setup in the current save location. The setup file to be loaded is specified by <filename>. <filename> should be enclosed in either single quotes (‘ ’) or double quotes (“ ”) and should contain a file extension “.stp”. Use the command MMEMory:MSIS to set the current save location. The <integer> parameter is not currently used, but it must be sent. Send a 1.
Parameter:
<integer>, <filename>
Related Command:
:MMEMory:STORe:STATe
:MMEMory:MSIS INTernal|USB
Front Panel Access
Shift‑7 (File), Recall
:MMEMory:LOAD:TRACe <integer>,<filename>
Title
Recall Measurement
Description:
The instrument must be in the mode of the saved trace in order to recall that trace.Use :INSTrument:SELect or :INSTrument:NSELect to set the mode. Recalls a previously stored measurement trace from the current save location. The saved measurement trace to be loaded is specified by <filename>. <filename> should be enclosed in either single quotes (‘ ’) or double quotes (“ ”) and should contain a file extension. Note that the trace specified by <filename> should be available at the current save location.
Use the command MMEMory:MSIS to set the current save location. The <integer> parameter is not currently used, but it must be sent. Send a 1.
File name extensions:
.edg” for GSM
.spa” for SPA
.wcd” for WCDMA
.wmxd” for WiMAX
.wmxe” for Mobile WiMAX
.vna” for Cable & Antenna
.cdma” for CDMA
.tds” for TDSCDMA
.evdo” for EVDO
.ia” for Interference Analysis
.cs” for Channel Scanner
.pm” for Power Meter
.tm” for Transmission Measurement
.afp” for AMFMPM
Note: Extensions not available for T1 and Hi_PM.
Parameter:
<integer>, <filename>
Example:
To recall trace with file name “trace”:
:MMEMory:LOAD:TRACe 1,”trace.spa”
Related Command:
:MMEMory:STORe:TRACe
:MMEMory:MSIS INTernal|USB
Front Panel Access
Shift‑7 (File), Recall Measurement
:MMEMory:STORe:STATe <integer>,<filename>
Title
Save Setup
Description:
Stores the current setup into the file specified by <filename>. <filename> should be enclosed in either single quotes (‘ ’) or double quotes (“ ”) and should not contain a file extension. Use the command MMEMory:MSIS to set the current save location. The <integer> parameter is not currently used, but it must be sent. Send a value of 0.
Parameter:
<integer>, <filename>
Related Command:
:MMEMory:LOAD:STATe
:MMEMory:MSIS INTernal|USB
Front Panel Access
Shift‑7 (File)
:MMEMory:STORe:TRACe <integer>,<filename>
Title
Save Measurement
Description:
Stores the trace into the file specified by <filename>. <filename> should be enclosed in either single quotes (‘ ’) or double quotes (“ ”) and should not contain a file extension. Use the command MMEMory:MSIS to set the current save location. The <integer> parameter is not currently used, but it must be sent. Send a 0. Note that existing files of the same name will not be overwritten.
Parameter:
<integer>, <filename>
Example:
To save the trace into the file name “trace”:
:MMEMory:STORe:TRACe 0,”trace”
Related Command:
:MMEMory:LOAD:TRACe
:MMEMory:MSIS INTernal|USB
Front Panel Access
Shift‑7 (File), Save