S331E, S332E, S361E, S362E Site Master™MS2711E, MS2712E, MS2713E Spectrum Master™MT8212E, MT8213E Cell Master™ Programming Manual : All Mode Commands : :SYSTem Subsystem
 
:SYSTem Subsystem
This subsystem contains commands that affect instrument functionality that does not directly relate to data collection, display or transfer.
:SYSTem:MSIS[:STATe]? INTernal|USB
Title
Query Memory State
Description
Queries the ready state of the instrument’s internal memory or of the USB Flash drive. Use this command to check the ready state of the memory device before sending a command, such as :MMEMory:STORe or :MMEMory:MSIS:COPY, that requires the memory location to be available.
The USB query returns a 1 when a USB device is plugged into the USB port. It returns 0 if no USB drive is present.
Internal memory should always be available and the INT query should always return a 1.
Parameter
INTernal|USB
Parameter Type
<char>
Related Command
:MMEMory:MSIS
:MMEMory:MSIS:DESTination
:MMEMory:MSIS:COPY
:SYSTem:OPTions?
Title
Query Installed Options
Description
Returns a string of the installed options. Options are separated by a “/”. The string returns “NONE” if no options are installed.
Related Command
*IDN?
:SYSTem:PRESet
Title
Preset
Description
This command restores all application parameters to their factory preset values. This does not modify system parameters such as language, volume or brightness.
Front Panel Access
Shift‑1 (Preset), Preset