S331E, S332E, S361E, S362E Site Master™MS2711E, MS2712E, MS2713E Spectrum Master™MT8212E, MT8213E Cell Master™ Programming Manual : EVDO Commands : :FETCh Subsystem
 
:FETCh Subsystem
This set of commands returns the most recent measurement data of the active measurement. They turnsnot switch to another measurement.
To make a new measurement, use the INITiate command. To get new measurement data, use the READ or MEASure query commands.
:FETCh:DEMod:CDPData?
Title
Fetch Demodulator Code Domain Power Data
Required Option
63
Description
Returns the most recent Code Domain Power Data measurement results.
Data is returned as 6 comma-delimited values: Active Data Power in the current user set unit (dBm/W/mW), Data Modulation, Rho Pilot, Rho Overall1, Max Data CDP in dB, and Min Data CDP in dB. All invalid values are replaced with “--”.
Related Command
:CONFigure:DEMod CDPData
:MEASure:DEMod:CDPData?
:READ:DEMod:CDPData?
Front Panel Access
Measurements, Demodulator, CDP Data
:FETCh:DEMod:CDPMac?
Title
Fetch Demodulator Code Domain Power MAC
Required Option
63
Description
Returns the most recent Code Domain Power MAC measurement results.
Data is returned as 8 comma-delimited values: Pilot & MAC Power in the current user set unit (dBm/W/mW), Channel Power in the current user set unit (dBm/W/mW), Frequency Error in Hz, Frequency Error PPM, Rho Pilot, Rho Overall1, Data Modulation, and Noise Floor in dB. All invalid values are replaced with “--”.
Related Command
:CONFigure:DEMod CDPMac
:MEASure:DEMod:CDPMac?
:READ:DEMod:CDPMac?
Front Panel Access
Measurements, Demodulator, CDP MAC
:FETCh:DEMod:SUMMary?
Title
Fetch Demodulator Summary
Required Option
63
Description
Returns the most recent Modulation Summary measurement results.
Data is returned as 12 comma-delimited values: Pilot & MAC Power in the current user set unit (dBm/W/mW), Channel Power in the current user set unit (dBm/W/mW), Rho Pilot, Rho Mac, Rho Data, Rho Overall1, Rho Overall2, Data Modulation, Noise Floor in dB, RMS Phase Error, Frequency Error in Hz, Tau in tens of microseconds. All invalid values are replaced with “--”.
Related Command
:CONFigure:DEMod SUMMary
:MEASure:DEMod:SUMMary?
:READ:DEMod:SUMMary?
Front Panel Access
Measurements, Demodulator, Modulation Summary
:FETCh:OTA:MPATh?
Title
Fetch OTA Multipath
Required Option
34
Description
Returns the most recent Multipath measurement results.
Data is returned as 14 comma-delimited values: six Ec/Io Values in dB, six Tau values in ps, Channel Power in the current user set unit (dBm/W/mW), and Multipath Power in dB. All invalid values are replaced with “--”.
Related Command
:CONFigure:OTA MPATh
:MEASure:OTA:MPATh?
:READ:OTA:MPATh?
Front Panel Access
Measurements, OTA, Multipath
:FETCh:PFail?
Title
Fetch PASS/FAIL
Description
Returns the most recent PASS/FAIL measurement results. Measurement results are returned in a block of ASCII text in the format of <header><block>. The ASCII header specifies the number of data bytes. It looks like #AX, where A is the number of digits in X and X is the number of bytes in the <block>. The block consists of a set of records which indicate individual test results. Records are comma-separated. Each record follows the format <test ID>: <input1> <input2> <min> <max> <value1> <value2> <PASS/FAIL/OPTION NOT INSTALLED>. The <test ID> field indicates which test was performed to retrieve these results. The < input1> and < input2> fields indicate the test setup. The <min> and <max> fields indicate the minimum and maximum values against which <value1> and <value2> were compared to arrive at the final PASS/FAIL result. If the specified test is not available in the instrument, the <PASS/FAIL> field turnsindicate “option not available” instead of “pass” or “fail”. All unused fields for a given test are represented by a double dash (“--”). To receive valid measurements, the Pass/Fail measurement must be the active. The current measurement can be queried using CONFigure?. Use the :CONFigure PFail command to set Pass/Fail as the active measurement.
Related Command
MEASure:PFail?
:CONFigure PFail
READ:PFail?
:FETCh:RF:ACPR?
Title
Fetch Adjacent Channel Power Ratio
Required Option
62
Description
Returns the most recent Adjacent Channel Power Ratio measurement results.
Data is returned as nine comma-delimited values: The Absolute Adjacent Channel 1 Power, Absolute Adjacent Channel 2 Power, Absolute Main Channel 1 Power, Absolute Main Channel 2 Power, Absolute Main Channel 3 Power, Absolute Main Channel 4 Power, Absolute Main Channel 5 Power, Absolute Adjacent Channel 3 Power, Absolute Adjacent Channel 4 Power. All values are returned in dBm. Note that the values for all five main channel carriers are shown even if the number of carriers set on the instrument is below five.
Related Command
:CONFigure:RF ACPR
:MEASure:RF:ACPR?
:READ:RF:ACPR?
Front Panel Access
Measurements, RF Measurements, ACPR
:FETCh:RF:EMISsion?
Title
Fetch RF Spurious Emission
Required Option
CDMA: 42
EVDO, TDSCDMA: 62
Description
Returns the most recent Spurious Emission measurement result.
Data is returned as five comma-delimited values for each marker/boundary (40 values total): Marker Amplitude in dB, Marker Frequency in Hz, RBW in Hz, Pass/Fail, and Mask Boundary Frequency in Hz. Markers that are not on turnsreturn “--” for Marker Amplitude, Marker Frequency, RBW, and Pass/Fail. All Mask Boundary Frequencies turnsshow normally.
 
Related Command
:CONFigure:RF EMISsion
:MEASure:RF:EMISsion?
:READ:RF:EMISsion?
Front Panel Access
Measurements, RF Measurements, Spurious Emission
:FETCh:RF:SPECtrum?
Title
Fetch RF Spectrum
Required Option
62
Description
Returns the most recent RF Channel Spectrum measurement results.
Data is returned as 4 comma-delimited values: Channel Power in the current user set unit (dBm/W/mW), Occupied bandwidth in Hz, Channel Power in fW, and Peak to Average Power in dB.
Related Command
:CONFigure:RF SPECtrum
:MEASure:RF:SPECtrum?
:READ:RF:SPECtrum?
Front Panel Access
Measurements, RF Measurements, Channel Spectrum