Backhaul Analyzer Measurement Guide : OC-3c Analyzer (Option 58) : Measurement Setup
 
Measurement Setup
1. Press the Configuration main menu key.
2. Select the desired Tx Clock by pressing either the Internal or Recovered submenu key.
3. Press the Error/Alarm main menu key. Use this menu to add error and/or alarms to the transmission path.
a. Press the Alarm Ins Setup submenu key. The Alarm Ins menu opens.
b. Select the desired alarm by pressing one of the 4 submenu keys – Line AIS, Line RDI, Path AIS, or Path RDI.
c. Press the Alarm Insert submenu key to On, to activate the selected alarm for testing.
d. Press the Back submenu key to return to the Error/Alarm menu.
e. Press the Error Ins Setup submenu key. The Error Ins menu opens.
f. Select the desired error by pressing one of the 3 submenu keys – Section BIP, Line BIP, or Path BIP.
g. Press the Error Insert submenu key to On, to activate the selected alarm for testing.
h. Press the Back submenu key to return to the Error/Alarm menu.
4. Press the Measurements main menu key. The Measurement menu opens.