Measurement Setup
1. Press the Configuration main menu key.
2. Select the desired Tx Clock by pressing either the Internal or Recovered submenu key.
3. Press the Error/Alarm main menu key. Use this menu to add error and/or alarms to the transmission path.
a. Press the Alarm Ins Setup submenu key. The Alarm Ins menu opens.
b. Select the desired alarm by pressing one of the 4 submenu keys – MS-AIS, MS-RDI, AU-AIS, or HP-RDI.
c. Press the Alarm Insert submenu key to On to activate the selected alarm for testing.
d. Press the Back submenu key to return to the Error/Alarm menu.
e. Press the Error Ins Setup submenu key. The Error Ins menu opens.
f. Select the desired error by pressing one of the 3 submenu keys – RS BIP, MS BIP, or HP BIP.
g. Press the Error Insert submenu key to On, to activate the selected alarm for testing.
h. Press the Back submenu key to return to the Error/Alarm menu.
4. Press the Measurement main menu key. The Measurements menu opens.