S331E, S332E, S361E, S362E Site Master™MS2711E, MS2712E, MS2713E Spectrum Master™MT8212E, MT8213E Cell Master™ Programming Manual : Tracking Generator Commands : :INITiate Subsystem
 
:INITiate Subsystem
This subsystem controls the triggering of measurements.
:INITiate:GENerator OFF|ON|0|1
:INITiate:GENerator?
Title
Generator On/Off
Description
Specifies whether the generator is on or off. If the value is set to ON or 1, the generator is turned on. If the value is set to OFF or 0, the generator is turned off.
The query version of the command returns a 1 if the generator is on and returns a 0 if the generator is off.
Parameter
OFF|ON|0|1
Parameter Type
<boolean>
Default Value
OFF
Example
To turn off generator:
:INITiate:GENerator OFF
To turn on generator:
:INITiate:GENerator ON
Related Command
[:SENSe]:GENerator:MODe
Front Panel Access
Shift-4 (Measure), Generator, Generator Output