S331E, S332E, S361E, S362E Site Master™MS2711E, MS2712E, MS2713E Spectrum Master™MT8212E, MT8213E Cell Master™ Programming Manual : All Mode Commands : :STATus Subsystem
 
:STATus Subsystem
The commands in this subsystem relate to the current operating state of the instrument.
:STATus:OPERation?
Title
Query Operation Status
Description
This command requests information about the current status of the instrument. Each bit of the return value represents some operation. Only a subset of the bits are implemented for each application. The number returned is the decimal representation of the bit-wise OR of the enabled bits.
Note 
Valid measurement modes that work with this command are SPA, GSM, WCDMA, TDSCDMA, CDMA, EVDO, Fixed WiMAX, and Mobile WiMAX.
Bit
Decimal Value
Description
0
1
Not implemented
1
2
Not implemented
2
4
Not implemented
3
8
Not implemented
4
16
Not implemented
5
32
Not implemented
6
64
Not implemented
7
128
Not implemented
8
256
Sweep Complete
This bit is set to 0 when the command :INITiate[:IMMediate] is sent to trigger a sweep. The bit will have a value of 1 when the sweep has completed.
9
512
Not implemented
10
1024
Not implemented
11
2048
Not implemented
12
4096
Not implemented
13
8192
Not implemented
14
16384
Not implemented
15
0
Will always be 0