S331E, S332E, S361E, S362E Site Master™MS2711E, MS2712E, MS2713E Spectrum Master™MT8212E, MT8213E Cell Master™ Programming Manual : WCDMA Commands : [:SENSe] Subsystem
 
[:SENSe] Subsystem
The commands in this subsystem relate to device-specific parameters, not signal-oriented parameters.
[:SENSe]:AVERage:FERRor OFF|ON|0|1
[:SENSe]:AVERage:FERRor?
Title
Frequency Error Averaging State
Description
Turns averaging for Frequency Error ON or OFF. Setting the value to ON or 1 will result in turning frequency error averaging ON.
The Query form of this command returns either “1” or “0”. “1” corresponds to frequency error averaging being ON and “0” corresponds to frequency error averaging being OFF.
Parameter
OFF|ON|0|1
Parameter Type
<boolean>
Default Value
OFF
Related Command
[:SENSe]:AVERage:FERRor:COUNt
[:SENSe]:AVERage:FERRor:COUNt?
:MMEMory:LOAD:TRACe
Front Panel Access
Setup, More, Freq Err Avg
[:SENSe]:AVERage:FERRor:COUNt <integer>
[:SENSe]:AVERage:FERRor:COUNt?
Title
Average Frequency Error Count
Description
Sets the number that is used for averaging the frequency error.
Parameter
<integer>
Parameter Type
<integer>
Default Value
2
Range
2 to 15
Related Command
[:SENSe]:AVERage:FERRor
[:SENSe]:AVERage:FERRor?
Front Panel Access
Setup, More, Freq Err Avg Cnt
[:SENSe]:DEMod:CODogram:TIME <seconds>
[:SENSe]:DEMod:CODogram:TIME?
Title
Codogram Measurement Time
Description
This command refers to the minimum elapsed time between successive codogram measurements.
Parameter
<seconds>
Default Value
5 seconds
Range
5 seconds to 6000 seconds
[:SENSe]:DEMod:CPICh:ABSolute?
Title
Absolute Common Pilot Channel (CPICH) Level
Description
Queries the absolute Common Pilot Channel level.
Default Unit
dB
Related Command
MEASure:DEMod:CDPower?
READ:DEMod:CDPower?
FETCh:DEMod:CDPower?
[:SENSe]:DEMod:CPICh:RELative?
Title
Relative Common Pilot Channel (CPICH) Level
Description
Queries the relative Common Pilot Channel level.
Default Unit
dB
Related Command
MEASure:DEMod:CDPower?
:READ:DEMod:CDPower?
:FETCh:DEMod:CDPower?
[:SENSe]:DEMod:CTRLchannels:UNIT RELative|ABSolute|DELTa
[:SENSe]:DEMod:CTRLchannels:UNIT?
Title
Control Channels Display Units
Description
This command refers to the display units for the control channels in the HSDPA and CDP view. Setting the value to RELative will result in displaying P-CCPCH, S-CCPCH, PICH, P-SCH and S-SCH in relative powers. Setting the value to ABSolute will result in displaying P-CCPCH, S-CCPCH, PICH, P-SCH and S-SCH in absolute powers.
Parameter
RELative|ABSolute|DELTa
Parameter Type
<char>
Default Value
RELative
Range
RELative|ABSolute|DELTa
Front Panel Access
Measurements, Demodulator, HSDPA, Control Channels,
Measurements, Demodulator, CDP, Control Channels
[:SENSe]:DEMod:HSDPa:IQPersistence <integer>
[:SENSe]:DEMod:HSDPa:IQPersistence?
Title
HSDPA IQ Persistence
Required Option
65
Description
Sets the number of samples before displaying the screen.
Parameter
<integer>
Parameter Type
<integer>
Default Value
1
Range
1 to 48
Front Panel Access
Measurements, Demodulator, HSDPA, IQ Persistence
[:SENSe]:DEMod:HSDPa:TIME <seconds>
[:SENSe]:DEMod:HSDPa:TIME?
Title
HSDPA Measurement Time
Required Option
65
Description
This command sets the single sweep time.
Parameter
<seconds>
Default Value
5 seconds
Range
5 to 6000 seconds
Front Panel Access
Measurements, Demodulator, HSDPA, Single Sweep Time
[:SENSe]:DEMod:PCCPch:RELative?
Title
Relative Primary Common Control Physical Channel (P-CCPCH) Level
Description
Queries the relative Primary Common Control Physical Channel level.
Default Unit
dB
Related Command
MEASure:DEMod:CDPower?
:READ:DEMod:CDPower?
:FETCh:DEMod:CDPower?
[:SENSe]:DEMod:PCDerror?
Title
Peak Code Domain Error
Description
Queries the Peak Code Domain Error.
Default Unit
dB
[:SENSe]:DEMod:PICH:CODE <code number>
[:SENSe]:DEMod:PICH:CODE?
Title
PICH Code Number
Description
This command refers to the channelization code number of the PICH channel for W-CDMA code domain demodulation measurements.
Parameter
<code number>
Default Value
16
Range
0 to 255
Front Panel Access
Setup, PICH Code
[:SENSe]:DEMod:SCCPch:CODE <code number>
[:SENSe]:DEMod:SCCPch:CODE?
Title
S-CCPCH Code Number
Description
This command refers to the channelization code number of the S-CCPCH channel for W-CDMA code domain demodulation measurements.
Parameter
<code number>
Default Value
3
[:SENSe]:DEMod:SCCPch:SFACtor 4|8|16|32|64|128|256
[:SENSe]:DEMod:SCCPch:SFACtor?
Title
S-CCPCH Spreading Factor
Description
This command refers to the spreading factor of the S-CCPCH channel for W-CDMA code domain demodulation measurements.
Parameter
4|8|16|32|64|128|256
Default Value
256
Front Panel Access
Setup, S-CCPCH Spread
[:SENSe]:DEMod:SCODe <scrambling code>
[:SENSe]:DEMod:SCODe?
Title
Scrambling Code
Description
This command refers to the primary scrambling code used for W-CDMA code domain demodulation measurements. When the auto scrambling code feature is turned on, this setting will be overwritten by the automatically detected value.
Parameter
<scrambling code>
Default Value
0
Range
0 to 255
Front Panel Access
Setup, Scrambling Code Setup, S-CCPCH Code
[:SENSe]:DEMod:SCODe:AUTO OFF|ON|0|1
[:SENSe]:DEMod:SCODe:AUTO?
Title
Automatic Scrambling Code Detection
Description
Sets the state of the automatic scrambling code detection feature. Setting the value to ON or 1 will result in the scrambling code being set to the code of the strongest detected signal. That is, the instrument will detect the strongest signal present and use the scrambling code of that signal for demodulation. Setting the value to OFF or 0 will force the instrument to base all demodulation on the user-selected scrambling code value. The default value is ON. That is, sending :SENS:DEM:SCOD:AUTO is equivalent to sending :SENS:DEM:SCOD:AUTO ON.
Parameter
OFF|ON|0|1
Parameter Type
<boolean>
Default Value
ON
Related Command
[:SENSE]:DEMod:SCODe
Front Panel Access
Setup, Scrambling Code
[:SENSe]:DEMod:SFACtor 256|512
[:SENSe]:DEMod:SFACtor?
Title
Maximum Spreading Factor
Description
This command refers to the maximum spreading factor used when demodulating a UMTS/W-CDMA signal.
Parameter
256|512
Default Value
512
Front Panel Access
Setup, Max Spreading
[:SENSe]:DEMod:THRShold <rel ampl>
[:SENSe]:DEMod:THRShold?
Title
Active Code Threshold
Description
This command refers to the threshold used for detecting active vs. inactive traffic channels in W-CDMA code domain demodulation measurements. If the automatic threshold feature is used, this setting will be overwritten by the automatically detected threshold.
Parameter
<rel ampl>
Default Value
-30 dB
Range
-50 dB to -10 dB
[:SENSe]:DEMod:THRShold:AUTO OFF|ON|0|1
[:SENSe]:DEMod:THRShold:AUTO?
Title
Automatic Threshold
Description
Sets the state of the automatic threshold feature. Setting the value to ON or 1 will enable the automatic threshold feature. Setting the value to OFF or 0 will disable the automatic threshold feature. The default value is ON. That is, sending :SENS:DEM:THRS:AUTO is equivalent to sending :SENS:DEM:THRS:AUTO ON.
Parameter
OFF|ON|0|1
Parameter Type
<boolean>
Default Value
ON
Related Command
[:SENSE]:DEMod:THRShold
Front Panel Access
Setup, More, Threshold
[:SENSe]:FREQuency:CENTer <freq>
[:SENSe]:FREQuency:CENTer?
Title
Center Frequency
Description
Sets the center frequency. Note that changing the value of the center frequency will change the value of the coupled parameters Start Frequency and Stop Frequency. It may also change the value of the span.
Parameter
<freq>
Default Value
1 GHz
Default Unit
Hz
Range
824 MHz to 2.7 GHz
Front Panel Access
Freq, Center Freq
[:SENSe]:FREQuency:SIGStandard:CHANnel <number>
[:SENSe]:FREQuency:SIGStandard:CHANnel?
Title
Channel Selection
Description
Sets the channel number for the selected signal standard.
Parameter
<number>
Front Panel Access
Freq, Channel
[:SENSe]:FREQuency:SIGStandard:NAMe <string>
[:SENSe]:FREQuency:SIGStandard:NAMe?
Title
Signal Standard
Description
Selects the desired signal standard from the list. The <string> argument is the name of the desired signal standard as displayed in the instrument’s current signal standard list. The list can be displayed on the instrument by choosing the Signal Standard submenu button in the Freq menu. The list can also be downloaded remotely and viewed using Anritsu Master Software Tools. For example, if the desired Signal Standard is P-GSM 900 - Uplink, then the value of the <string> argument would be “P-GSM 900 - Uplink”. The query form of this command will return the name of the currently selected Signal Standard on the list.
Parameter
<string>
Front Panel Access
Freq, Signal Standard
[:SENSe]:FREQuency:STARt?
Title
Start Frequency
Description
Queries the start frequency of the RF Band Spectrum. Note that this command is valid only if the current view is set to RF Band Spectrum.
Parameter
<freq>
Default Unit
Hz
Related Command
[:SENSe]:FREQuency:STOP?
Front Panel Access
Freq, Start Freq
[:SENSe]:FREQuency:STOP?
Title
Stop Frequency
Description
Queries the stop frequency of the RF Band Spectrum. Note that this command is valid only if the current view is set to RF Band Spectrum.
Parameter
<freq>
Default Unit
Hz
[:SENSe]:OTA:RESet
Title
OTA Reset
Description
This command forces the instrument to reset the over-the-air measurement and start fresh without any history. When the auto scrambling code feature is ON the RESet command will clear the list of scrambling codes and attempt to detect new codes. When the auto scrambling code feature is OFF the RESet command will force the instrument to take new measurements for all of the user-selected scrambling codes.
Front Panel Access
Measurements, OTA, Scrambling Code, Reset
[:SENSe]:OTA:SCODe:AUTO OFF|ON|0|1
[:SENSe]:OTA:SCODe:AUTO?
Title
Automatic OTA Scrambling Code Detection
Description
Sets the state of the automatic scrambling code detection feature. Setting the value to ON or 1 will result in the scrambling codes being set to the codes of the strongest detected signals. That is, the instrument will detect the strongest signals present. Setting the value to OFF or 0 will force the instrument to base all over-the-air measurements on the user-selected scrambling code values. The default value is ON. That is, sending :SENS:DEM:OTA:SCOD:AUTO is equivalent to sending :SENS:DEM:OTA:SCOD:AUTO ON.
Parameter
OFF|ON|0|1
Parameter Type
<boolean>
Default Value
ON
Related Command
[:SENSE]:DEMod:OTA:SCODe
Front Panel Access
Measurements, OTA, Scrambling Code, Scrambling Code (Auto)
[:SENSe]:OTA:SCODe:LOCK OFF|ON|0|1
[:SENSe]:OTA:SCODe:LOCK?
Title
OTA Scrambling Code Lock
Description
This command refers to the primary scrambling codes used for W-CDMA over-the-air measurements. When scrambling code lock is ON, the instrument will not search for any new scrambling codes and will only measure the codes that have already been detected. When scrambling code lock is OFF, the instrument will dynamically update the list of scrambling codes that are to be included in the current measurements. This feature has no effect when scrambling code auto detection is OFF for over-the-air measurements. The default value for this command is ON. That is, sending SENS:DEM:OTA:LOCK is equivalent to SENS:DEM:OTA:LOCK ON.
Parameter
OFF|ON|0|1
Parameter Type
<boolean>
Default Value
OFF
Front Panel Access
Measurements, OTA, Scrambling Code, Code Lock
[:SENSe]:OTA:SCODe{1|2|3|4|5|6}<scrambling code>
[:SENSe]:OTA:SCODe{1|2|3|4|5|6}?
Title
OTA Scrambling Code
Description
This command refers to the primary scrambling codes used for W-CDMA over-the-air measurements. To disable the specified code use a scrambling code value of ’–1’. When the auto scrambling code feature is turned on, setting this value has no direct effect on measurement results.
Parameter
<scrambling code>
Default Value
–1
Range
–1 to 511
Front Panel Access
Measurements, OTA, Scrambling Code, Manual Code
[:SENSe]:OTA:SORT CODE|POWer
[:SENSe]:OTA:SORT?
Title
OTA Sort Parameter
Description
This command refers to the parameter that is used to sort the over-the-air measurement results.
Parameter
CODE|POWer
Parameter Type
<char>
Default Value
CODE
Front Panel Access
Measurements, OTA, Scrambling Code, Sort By
 
[:SENSe]:PFail <test set>
[:SENSe]:PFail?
Title
PASS/FAIL Test Selection
Description
Selects the active test set to be used in subsequent PASS/FAIL measurements. The <test set> value must correspond to a test set that is defined in the test set list. For more information on loading test sets to the instrument, see the :MMEMory:STORe:PFail command. NOTE: The first test set in the list would be test set 0, the next test set would be 1, etc.
When using the query form of the command, the return value is the currently selected test set number. If there is not a valid test set selected, the return value is “-1” (negative 1).
Parameter
<test set>
Related Command
:CONFigure PFail
Front Panel Access
Measurements, Pass/Fail Mode, Select Pass/Fail Test
[:SENSe]:POWer[:RF]:RANGe:AUTO OFF|ON|0|1
[:SENSe]:POWer[:RF]:RANGe:AUTO?
Title
Automatic Amplitude Range
Description
Sets the automatic amplitude range. Setting the value to ON or 1 will result in the amplitude range being coupled to the detected input signal level. Setting the value to OFF or 0 will result in the input attenuation being un-coupled from the input signal level. That is, changing the input signal level will not change the amplitude range. When this command is issued, the amplitude range itself will not change. The default value is ON. That is, sending :SENS:POW:RANG:AUTO is equivalent to sending :SENS:POW:RANG:AUTO ON.
Parameter
OFF|ON|0|1
Parameter Type
<boolean>
Default Value
ON
Related Command
[:SENSe]:POWer[:RF]:RANGe
Front Panel Access
Amplitude, Auto Range
[:SENSe]:POWer[:RF]:RANGe[:IMMediate]
Title
Amplitude Range
Description
Re-calculates amplitude range. Note that issuing this command will set the automatic dynamic range OFF.
Related Command
[:SENSe]:POWer[:RF]:RANGe:AUTO
Front Panel Access
Amplitude, Adjust Range
[:SENSe]:RF:ACLR:ADJCchannelcount <num of channels>
[:SENSe]:RF:ACLR:ADJCchannelcount?
Title
ACLR ADJC Channel Count
Description
This command refers to the number of Adjacent channels in the ACLR view.
Parameter
<num of channels>
Default Value
2
Range
1 to 4
Front Panel Access
Measurements, RF Measurements, ACLR, Select # of Adjacent Channels
[:SENSe]:RF:ACLR:MAINchannelcount <num of main channels>
[:SENSe]:RF:ACLR:MAINchannelcount?
Title
ACLR MAIN Channel Count
Description
This command refers to the number of main channels in the ACLR view.
Parameter
<num of main channels>
Default Value
1 Main Channel
Range
1 to 4
Front Panel Access