General Information : LTE Commands : [:SENSe] Subsystem

[:SENSe] Subsystem
The commands in this subsystem relate to device-specific parameters, not signal-oriented parameters.
[:SENSe]:BANDWidth[:RESolution] 1.4|3|5|10|15|20
[:SENSe]:BANDWidth[:RESolution]?
Title
Bandwidth
Description
Sets the channel bandwidth. 15 MHz and 20 MHz are only available if Option 543 is installed.
Parameter
1.4|3|5|10|15|20
Parameter Type
<char>
Default Value
The default bandwidth is 10 MHz.
Front Panel Access
Setup, BW
[:SENSe]:CELLID <char>
[:SENSe]:CELLID?
Title
Cell ID
Description
Sets the Cell ID value used when Sync Type is set to ‘RS’.
Parameter
(the known Cell ID)
Parameter Type
<char>
Front Panel Access
Setup, Sync (RS), Cell ID
[:SENSe]:EVM:MODe AUTO|PBCHonly
[:SENSe]:EVM:MODe?
Title
Set EVM Mode
Description
Sets/Returns the EVM Mode to either Auto or PBCH Only.
Parameter
AUTO|PBCHonly
Parameter Type
<char>
Default Value
AUTO
Front Panel Access
Setup, EVM Mode
[:SENSe]:FREQuency:CENTer <freq>
[:SENSe]:FREQuency:CENTer?
Title
Center Frequency
Description
Sets the center frequency.
Parameter
<freq>
Default Value
1 GHz
Default Unit
Hz
Range
10 MHz to 4 GHz
Front Panel Access
Freq, Center Freq
[:SENSe]:FREQuency:SIGStandard:CHANnel <number>
[:SENSe]:FREQuency:SIGStandard:CHANnel?
Title
Channel Selection
Description
Sets the channel number for the selected signal standard.
Parameter
<number>
Front Panel Access
Frequency, Channel
[:SENSe]:FREQuency:SIGStandard:NAMe [String]
[:SENSe]:FREQuency:SIGStandard:NAMe?
Title
Signal Standard
Description
Selects the desired signal standard from the list. The <string> argument is the name of the desired signal standard as displayed in the instrument’s current signal standard list. The list can be seen on the instrument by choosing the Signal Standard submenu
button in the Freq menu. The list can also be downloaded remotely and viewed using Anritsu Master Software Tools. For example, if the desired Signal Standard is
P-GSM 900 - Uplink, then the value of the <string> argument would be
“P-GSM 900 - Uplink”.
The query form of this command will return the name of the currently selected Signal Standard from the list.
Parameter
<string>
Front Panel Access
Freq, Signal Standard
[:SENSe]:POWer[:RF]:RANGe[:IMMediate]
Title
Amplitude Range
Description
Re-calculates amplitude range. Note that issuing this command will set the automatic dynamic range OFF.
Related Command
[:SENSe]:POWer[:RF]:RANGe:AUTO
Front Panel Access
Amplitude, Adjust Range
[:SENSe]:POWer[:RF]:RANGe:AUTO <Boolean (default=1 [ON])>
[:SENSe]:POWer[:RF]:RANGe:AUTO?
Title
Automatic Amplitude Range
Description
Sets the automatic amplitude range. Setting the value to ON or 1 will result in the amplitude range being coupled to the detected input signal level. Setting the value to OFF or 0 will result in the input attenuation being un-coupled from the input signal level. That is, changing the input signal level will not change the amplitude range. When this command is issued, the amplitude range itself will not change. The default value is ON. That is, sending :SENS:POW:RANG:AUTO is equivalent to sending :SENS:POW:RANG:AUTO ON.
Parameter
OFF|ON|0|1
Parameter Type
<boolean>
Default Value
ON
Related Command
[:SENSe]:POWer[:RF]:RANGe
Front Panel Access
Amplitude, Auto Range
[:SENSe]:RF:SPECtrum:SPAN Auto|1.4|3|5|10|15|20|30
[:SENSe]:RF:SPECtrum:SPAN?
Description
Sets the span for the Spectrum view. For example, setting the value to 5 will set the span for the Spectrum view to 5 MHz and setting the value to 20 will set the span for the Spectrum view to 20 MHz.
Parameter
Auto|1.4|3|5|10|15|20|30
Default Value
Auto
Default Unit
MHz
Front Panel Access
Measurements, RF, Channel Spectrum, Span
[:SENSe]:SYNC:TYPe SS|RS
[:SENSe]:SYNC:TYPe?
Title
Set Sync Type
Description
Sets the sync type setting.
Parameter
SS|RS
Parameter Type
<char>
Default Value
SS
Front Panel Access
Setup, Sync, Sync Type
 
 

Copyright 2010 Anritsu Company
Anritsu Company
1-800-ANRITSU
10450-00024, Rev. B