Refer to Figure: “Impulse Response Measurement” for a typical screen image of an Impulse Response measurement.
1. Press the Measurements main menu key.
2. Press the Impulse Response submenu key to select and display the Impulse Response measurement screen.
3. Press the Impulse Response submenu key again to open the “Impulse Response Menu” in order to set up the y‑axis vertical range and the waveform display.
1.
2. Press one of the four range‑value submenu keys to set the vertical axis (y‑axis) of the Impulse Response graphs to: 5 dB, 10 dB, 20 dB, or 40 dB.
3. Press Back to return to the Impulse Response menu.
1.
2. Set up the following parameters by pressing each submenu key (if necessary) to toggle the setting On or Off: Last Result, Power Method, and Transfer Method. The current setting of each parameter is underlined.
3. Press Back to return to the Impulse Response menu.