Meas Setup (1/2) MenuKey Sequence: Setup
Meas Setup (1/2) Menu Meas ModePress this submenu key to open the Select Meas Mode list box to select between Single or Continuous measurement mode. Refer to the “Measurement Mode” section that follows this menu description.Trigger SweepPress this submenu key to initiate a single sweep when Meas Mode is set to Single. This key has no function when the instrument is in Continuous sweep mode.Detect Parameter OncePress this submenu key to manually detect TPS and Mode, GI information from the input signal. Measurement begins when parameters are detected. For additional information, refer to “Physical Layer” and “2K, 4K, 8K Modes and Guard Intervals”, and to “Automatic Detection of Parameters”.Advanced SettingsSingle measurement mode sets up the test for one measurement. The instrument acquires the measurement and displays the results. This mode is useful for capturing screen images. Press the Trigger Sweep submenu key when you are ready to take a measurement.Continuous measurement mode sets up the instrument to take measurements continuously and display the results. This mode is helpful for real‑time signal analysis.