SCPI CommandsPlease refer to your instrument’s programming manual for the use of SCPI commands. This set of commands prepares the PIM instrument hardware for the selected measurement. They activate the specified measurement and sets the instrument to a wait-for-sweep mode, waiting for an :INITiate command to take a measurement.[SENSe]:PIManalyzer:FREQuency:F1 1930000000 (Sets F1 to 1930 MHz)[SENSe]:PIManalyzer:FREQuency:F2 1990000000 (Sets F2 to 1990 MHz)
[SENSe]:PIManalyzer:AUTorange 1 (Sets Amplitude to Auto Range )[SENSe]:PIManalyzer:IMD:ORDer 3 (Sets center frequency of Rx to IM3)[SENSe]:PIManalyzer:OUTPut:POWer 2 (Sets power to 20 Watts)[SENSe]:PIManalyzer:TEST:DURation 10 (Sets the power on time)CONFigure:PIManalyzer:SETup (Sends configuration to the PIM Master)INITiate:PIManalyzer:MEASure PIM (Starts PIM measurement)