LMR Masterâ„¢ S412E Programming Manual : DMR Commands : :CONFigure Subsystem
 
:CONFigure Subsystem
This set of commands prepares the instrument for the selected measurement. It disables any currently-enabled measurements and activates the specified measurement.
Current instrument settings may be changed to default values. These changes are identified with their respective measurement commands.
Note 
Sending a non-query :CONFigure command will change the Sweep setting from Run to Hold.
:CONFigure?
Description
:CONFigure? query returns the name of the measurement previously set up using a CONFigure command or a MEASure? query. The list below shows the possible return values and the actual names of each configuration.
Returns Value
Actual Name
SIGA
DMR Analyzer
COV
DMR Coverage
BITC
DMR Bit Capture
Cmd Parameters:
NA
Query Parameters:
NA
Range
NA
Default Value
NA
Default Unit
NA
Example
To query the current measurement type:
:CONFigure?
Front Panel Access
Measurement
:CONFigure:BITCap
Description
This command configures the DMR Bit Capture measurement. Certain settings from the previous measurement (Ref Lvl, Scale, Graph Types, Maximize) will be backed up when exiting this measurement and restored when entering this measurement. All other settings carry over from one measurement to the other. Please note that you must have the Rx pattern set to VOICe to set the DMR Bit Capture measurement.
Cmd Parameters:
NA
Query Parameters:
NA
Range
NA
Default Value
NA
Default Unit
NA
Example
To switch the measurement to DMR Bit Capture:
:CONFigure:BITCap
Related Command
:DM:PATTern VOICe
Front Panel Access
Measurement, DMR Bit Capture
:CONFigure:COVerage
Description
This command configures the DMR Coverage measurement. Certain settings from the previous measurement (Mapping Type) will be backed up when exiting this measurement and restored when entering this measurement. All other settings carry over from one measurement to the other.
Cmd Parameters:
NA
Query Parameters:
NA
Range
NA
Default Value
NA
Default Unit
NA
Example
To switch the measurement to DMR Coverage:
:CONFigure:COVerage
Front Panel Access
Measurement, DMR Coverage
:CONFigure:SIGAnalyzer
Description
This command configures the DMR Analyzer measurement. Certain settings from the previous measurement (Ref Lvl, Scale, Graph Types, Maximize) will be backed up when exiting this measurement and restored when entering this measurement. All other settings carry over from one measurement to the other.
Cmd Parameters:
NA
Query Parameters:
NA
Range
NA
Default Value
NA
Default Unit
NA
Example
To switch the measurement to DMR Analyzer:
:CONFigure:SIGAnalyzer
Front Panel Access
Measurement, DMR Analyzer