LMR Master™ S412E Programming Manual : NBFM Commands : :DISPlay Subsystem
 
:DISPlay Subsystem
This subsystem provides commands that modify the display of data for the user. They do not modify the way in which data are returned to the controller.
:DISPlay[:WINDow]:TRACe:FORMat:COVerage <mapping type>
:DISPlay[:WINDow]:TRACe:FORMat:COVerage?
Description
Defines the mapping type. <mapping type> is the type of data that is being mapped. Note that RSSI, THD, SINAD, and External SINAD data will be stored, but only the selected mapping type will be used in the comparisons to determine the color of the points on the map. Mapping type must be one of the following values:
RSSI|THD|SINad|EXTS
The query version of this command returns “RSSI” if the mapping type is set to RSSI, “THD” if set to THD, “SIN” if set to SINAD, and “EXTS” if set to External SINAD.
Please note that this command only works when the current measurement is set to NBFM Coverage. Refer to the Related Command.
Cmd Parameters:
<mapping type>
Query Parameters:
NA
Range
RSSI|THD|SINad|EXTS
Default Value
RSSI
Default Unit
NA
Example
To set mapping type to SINAD:
:DISPlay:TRACe:FORMat:COVerage SINad
Related Command
:CONFigure:COVerage
Front Panel Access
Measurement, NBFM Coverage, Mapping Type
:DISPlay[:WINDow]:TRACe:SELect?
Description
This command returns the current active trace number in the format TRAC#.
Cmd Parameters:
NA
Query Parameters:
NA
Range
NA
Default Value
NA
Default Unit
NA
Example
To query for the active trace number:
:DISPlay:TRACe:SELect?
Front Panel Access
Measurement, NBFM Analyzer, Active Graph
:DISPlay[:WINDow]:TRACe:Y[:SCALe]:IFPercent <Percentage>
:DISPlay[:WINDow]:TRACe:Y[:SCALe]:IFPercent?
Description
Sets the IF bandwidth percent. This setting adjusts the Y-Axis scale for the Audio Spectrum and Audio Waveform graphs in the NBFM Analyzer measurement mode.
Cmd Parameters:
<Percentage>
Query Parameters:
NA
Range
1% to 100%
Default Value
50.00
Default Unit
NA
Example
To change the IF Bandwidth % to 30%:
:DISPlay:TRACe:Y:IFPercent 30.00
Front Panel Access
Front Panel Access
Setup, Filters, % IFBW
:DISPlay[:WINDow]:TRACe:Y[:SCALe]:PDIVision <value>
:DISPlay[:WINDow]:TRACe:Y[:SCALe]:PDIVision?
Description
Sets the scale per division for the y-axis. In the NBFM Analyzer measurement, this value corresponds to the scale on the spectrum graph type.
Cmd Parameters:
<value>
Query Parameters:
NA
Range
1 to 15
Default Value
10
Default Unit
NA
Example
To set the scale to 8:
:DISPlay:TRACe:Y:PDIVision 8
Front Panel Access
Amplitude, Scale
:DISPlay[:WINDow]:TRACe:Y[:SCALe]:RLEVel <value>
:DISPlay[:WINDow]:TRACe:Y[:SCALe]:RLEVel?
Description
Sets the reference level scale value for the y-axis. In the NBFM Analyzer measurement, this value corresponds to the reference level on the spectrum graph type.
Note 
Turning auto range on will automatically adjust the reference level. If auto range is on and this command is sent, the reference level will be set to the value until the next sweep. If auto range is off, the unit will keep the value until either auto range is turned back on, the reference level is changed, or a preset is activated.
Cmd Parameters:
<value>
Query Parameters:
NA
Range
-300 dBm to 40 dBm
Default Value
0 dBm
Default Unit
dBm
Example
To set the reference level to –40:
:DISPlay:TRACe:Y:RLEVel -40
Front Panel Access
Amplitude, Ref Lvl
:DISPlay[:WINDow]:TRACe<Tr>:FORMat:SIGAnalyzer <graph type>
:DISPlay[:WINDow]:TRACe<Tr>:FORMat:SIGAnalyzer?
Description
Defines the graph type for the given trace <Tr>. <Tr> is the trace number in the range 1 to 4. If no trace number is specified, then the <Tr> parameter defaults to trace number 1. <Graph Type> is the graph type to which the specified trace is set, and it must be one of the following values:
SPECtrum|ASPEctrum|AWAVeform|SUMMary
The query version of this command returns “SPEC” if the specified trace graph type is set to Spectrum, “ASPE” if set to Audio Spectrum, “AWAV” if set to Audio Waveform, and “SUMM” if set to Summary.
Please note that this command only works when the current measurement is set to NBFM Analyzer. Refer to the Related Command below.
Cmd Parameters:
<graph type>
Query Parameters:
NA
Range
SPECtrum|ASPEctrum|AWAVeform|SUMMary
Default Value
Trace 1:Spectrum
Trace 2: Audio Spectrum
Trace 3: Audio Waveform
Trace 4: Summary
Default Unit
NA
Example
To set Trace 2 graph type to Audio Waveform:
:DISPlay:TRACe2:FORMat:SIGAnalyzer AWAVeform
Related Command
:CONFigure:SIGAnalyzer
Front Panel Access
Measurement, NBFM Analyzer, Graph Type
:DISPlay[:WINDow]:TRACe<Tr>:SELect
Description
Selects the given trace, <Tr>, as the active trace. <Tr> is the trace number in the range 1 to 4 for NBFM Analyzer. If no trace number is specified, then the <Tr> parameter defaults to trace number 1.
Cmd Parameters:
NA
Query Parameters:
NA
Range
NA
Default Value
TRAC1
Default Unit
NA
Example
To set trace 2 as the active trace:
:DISPlay:TRACe2:SELect
Front Panel Access
Measurement, NBFM Analyzer, Active Graph