PIM Master™ Passive Intermodulation Analyzer : Preset State Definitions : State D – PCS/AWS 1900/2100 20W

State D – PCS/AWS 1900/2100 20W
PCS/AWS 1900/2100 20W, F1 1930 MHz, F2 2110 MHz to 2155 MHz,
1705 MHz to 1750 MHz 3rd IM
Start Distance: 0 meters
Stop Distance: 50 meters
F1 Frequency: 1930 MHz
F2 Start Frequency: 2110 MHz
F2 Stop Frequency: 2155 MHz
Data Points: 128
Cable: None
Propagation velocity: 1
Cable loss: 0
Power level: 20 watts.
 
State E – PCS/AWS 1900/2100 40W
PCS/AWS 1900/2100 40W, F1 1930 MHz, F2 2110 MHz to 2155 MHz,
1705 MHz to 1750 MHz 3rd IM
Start Distance: 0 meters
Stop Distance: 50 meters
F1 Frequency: 1930 MHz
F2 Start Frequency: 2110 MHz
F2 Stop Frequency: 2155 MHz
Data Points: 128
Cable: None
Propagation velocity: 1
Cable loss: 0
Power level: 40 watts.
 
 
 
 
 
 

Copyright 2010, 2011 Anritsu Company
Anritsu Company
1-800-ANRITSU
10450-00027, Rev. B