Selects the desired signal standard from the list. The <string> argument is the name of the desired signal standard as displayed in the instrument’s current signal standard list. The list can be displayed on the instrument by choosing the Signal Standard submenu button in the Freq menu. The list can also be downloaded remotely and viewed using Anritsu Master Software Tools. For example, if the desired Signal Standard is P-GSM 900 - Uplink, then the value of the <string> argument would be “P-GSM 900 - Uplink”.
The query form of this command returns the name of the currently selected Signal Standard from the list.
Parameter
<string>
Parameter Type
<char>
Front Panel Access
Measurements, Over‑the‑Air, Carrier Aggregation, CC#, CC#, Signal Standard
[:SENSe]:CELLID <char> [:SENSe]:CELLID?
Title
Cell ID
Description
Sets the Cell ID value used when Sync Type is set to ‘RS’.
Parameter
(the known Cell ID)
Parameter Type
<char>
Front Panel Access
Setup, Sync (RS), Cell ID
[:SENSe]:EMF:STATe OFF|ON|0|1 [:SENSe]:EMF:STATe?
Title
EMF State
Description
Switches EMF ON or OFF.
The query form of this command returns a 0 or 1 when EMF state is OFF or ON, respectively.
Note: EMF will turn ON only if the start and stop frequencies are within the frequency range of the signal analyzer and isotropic antenna used. The antenna must be connected.
Selects the desired signal standard from the list. The <string> argument is the name of the desired signal standard as displayed in the instrument’s current signal standard list. The list can be displayed on the instrument by choosing the Signal Standard submenu button in the Freq menu. The list can also be downloaded remotely and viewed using Anritsu Master Software Tools. For example, if the desired Signal Standard is P‑GSM 900 - Uplink, then the value of the <string> argument would be “P‑GSM 900 - Uplink”.
The query form of this command will return the name of the currently selected Signal Standard from the list.
Parameter
<string>
Front Panel Access
Freq, Signal Standard
[:SENSe]:LTE:STATus?
Title
Sweep Status
Description
Returns 1 when the sweep is complete. Returns 0 when the sweep is in progress.
Front Panel Access
None
[:SENSe]:POWer[:RF]:RANGe[:IMMediate]
Title
Amplitude Range
Description
Re‑calculates amplitude range. Note that issuing this command will set the automatic dynamic range OFF.
Sets the automatic amplitude range. Setting the value to ON or 1 will result in the amplitude range being coupled to the detected input signal level. Setting the value to OFF or 0 will result in the input attenuation being uncoupled from the input signal level. That is, changing the input signal level will not change the amplitude range. When this command is issued, the amplitude range itself will not change. The default value is ON. That is, sending :SENS:POW:RANG:AUTO is equivalent to sending :SENS:POW:RANG:AUTO ON.
Sets the span for the Spectrum view. For example, setting the value to 5 will set the span for the Spectrum view to 5 MHz and setting the value to 20 will set the span for the Spectrum view to 20 MHz.
Parameter
Auto|1.4|3|5|10|15|20|30
Default Value
Auto
Default Unit
MHz
Front Panel Access
Measurements, RF, Channel Spectrum, Span
[:SENSe]:SYNC:TYPe SS|RS [:SENSe]:SYNC:TYPe?
Title
Set Sync Type
Description
Sets the sync type setting.
Parameter
SS|RS
Parameter Type
<char>
Default Value
SS
Front Panel Access
Setup, Sync, Sync Type
[:SENSe]:TAE:ACTive OFF|ON [:SENSe]:TAE:ACTive?
Title
Time Alignment Error
Description
Sets the state of the TAE measurement for OTA carrier aggregation.