VNA Masterâ„¢Programming Manual : Vector Voltmeter Commands : [:SENSe]:VVM:FREQuency Subsystem
 
[:SENSe]:VVM:FREQuency Subsystem
This subsystem contains commands pertaining to the frequency settings of the Vector Voltmeter.
CW Frequency
[:SENSe]:VVM:FREQuency:CW <freq>
Description
Sets the VVM CW frequency. The query format of the command returns the CW frequency.
Query
[:SENSe]:VVM:FREQuency:CW?
Syntax
[:SENSe]:VVM:FREQuency:CW <freq>
Cmd Parameter
<NRf> <freq> (hertz)
Query Response
<NR3> <freq> (hertz)
Range
5 kHz to 20 GHz for MS2028C, MS2038C
5 kHz to 15 GHz for MS2027C, MS2037C
5 kHz to 6 GHz for MS2026C, MS2036C
Default Value
5000 Hz
Default Unit
Hz
Front Panel Access
CW/Table, CW Frequency