Spectrum Masterâ„¢ Programming Manual : 3 Remote Commands : :CALCulate:MARKer Subsystem

:CALCulate:MARKer Subsystem
This subsystem contains commands to manipulate data markers.
Turn All Markers Off
:CALCulate:MARKer:AOFF
Turns off all markers.
 
Delta Marker State
:CALCulate:MARKer[1]|2|3|4|5|6:DELTa[:STATe] OFF|ON|0|1
:CALCulate:MARKer[1]|2|3|4|5|6:DELTa[:STATe]?
Sets the specified delta marker on/off.
 
Delta Marker X Value
:CALCulate:MARKer[1]|2|3|4|5|6:DELTa:X <x-parameter>
:CALCulate:MARKer[1]|2|3|4|5|6:DELTa:X?
Sets the location of the delta marker on the x-axis at the specified location <x-parameter> + the reference marker x-axis. <x-parameter> is defined in the current x-axis units.
The query version of the command returns the location of the delta marker on the x-axis.
 
Delta Marker Read Y Value
:CALCulate:MARKer[1]|2|3|4|5|6:DELTa:Y?
Reads the current Y value for the specified delta marker. The units are the units of the y-axis.
 
Marker (Maximum) Peak Search
:CALCulate:MARKer[1]|2|3|4|5|6:MAXimum
Puts the specified marker at the maximum amplitude in the trace.
 
Marker (Maximum) Peak Search Left
:CALCulate:MARKer[1]|2|3|4|5|6:MAXimum:LEFT
Puts the specified marker on the next highest peak to the left of the current peak.
The next highest peak must be above the peak threshold. If no point meets that criterion, the marker is set to the first point on the trace. Note that this command is valid only if the specified marker is on.
 
Marker (Maximum) Peak Search Right
:CALCulate:MARKer[1]|2|3|4|5|6:MAXimum:RIGHt
Puts the specified marker on the next highest peak to the right of the current peak.
The next highest peak must be above the peak threshold. If no point meets that criterion, the marker is set to the last point on the trace. Note that this command is valid only if the specified marker is on.
 
 
Peak Threshold
:CALCulate:MARKer:PEAK:THReshold <percentage>
:CALCulate:MARKer:PEAK:THReshold?
Sets the peak/valley threshold as a percentage of the display.
:CALCulate:MARKer:MAXimum:LEFT and :CALCulate:MARKer:MAXimum:RIGHt use this value to determine whether a particular display point qualifies as a peak.
 
 
Marker Frequency to Center
:CALCulate:MARKer[1]|2|3|4|5|6[:SET]:CENTer
Sets the center frequency equal to the frequency of the specified marker.
Note that this will result in a change to the start and stop frequencies and may also result in a change to the span.
 
Marker to Reference Level
:CALCulate:MARKer[1]|2|3|4|5|6[:SET]:RLEVel
Sets the reference level equal to the measured amplitude of the specified marker.
Note that this may result in a change to the input attenuation.
 
Marker State
:CALCulate:MARKer[1]|2|3|4|5|6[:STATe] OFF|ON|0|1
:CALCulate:MARKer[1]|2|3|4|5|6[:STATe]?
Sets the specified marker on/off.
 
Marker X Value
:CALCulate:MARKer[1]|2|3|4|5|6:X <x-parameter>
:CALCulate:MARKer[1]|2|3|4|5|6:X?
Sets the location of the marker on the x-axis at the specified location. <x-parameter> is defined in the current x-axis units.
The query version of the command returns the location of the marker on the x-axis.
 
Marker Read Y Value
:CALCulate:MARKer[1]|2|3|4|5|6:Y?
Reads the current Y value for the specified marker. The units are the units of the y-axis.
 

Copyright 2011 Anritsu Company
Anritsu Company
1800-ANRITSU
10450-00034, Rev. A
mmdtechpubs@anritsu.com