Triggers a new adjacent channel power ratio measurement and returns the results: main channel power, lower adjacent and upper adjacent channel power. It is a combination of the commands :ABORT;:INITiate;:FETCh:ACPower?The channel power measurement must be the active measurement (specified by :CONFigure:ACPower). The current measurement can be queried using :CONFigure?
Triggers a new channel power measurement and returns the results: channel power and channel power density. It is a combination of the commands :ABORT;:INITiate;:FETCh:CHPower?The channel power measurement must be the active measurement (specified by :CONFigure:CHPower). The current measurement can be queried using :CONFigure?
It is a combination of the commands :ABORT;:INITiate;:FETCh:CHPower:CHPower?It returns only the channel power, not the channel power density. Use :READ:CHPower? to get both channel power and channel power density.The channel power measurement must be the active measurement (specified by :CONFigure:CHPower). The current measurement can be queried using :CONFigure?
It is a combination of the commands :ABORT;:INITiate;:FETCh:CHPower:DENSity?It returns only the channel power density, not the channel power. Use :READ:CHPower? to get both channel power and channel power density.The channel power measurement must be the active measurement (specified by :CONFigure:CHPower). The current measurement can be queried using :CONFigure?
Triggers a new occupied bandwidth measurement and returns the results: occupied bandwidth, percent of power and dB down. It is a combination of the commands :ABORT;:INITiate;:FETCh:OBWidth?The occupied bandwidth measurement must be the active measurement (specified by :CONFigure:OBWidth). The current measurement can be queried using :CONFigure?
Triggers a new tracking generator absolute statistic measurement and returns the results. It is a combination of the commands :ABORT;:INITiate;:FETCh:TGENerator:ABSStats?The tracking generator absolute statistic measurement must be the active measurement (specified by :CONFigure:TGENerator ABSStats). The current measurement can be queried using :CONFigure?
Triggers a new tracking generator relative statistics measurement and returns the results. It is a combination of the commands :ABORT;:INITiate;:FETCh:TGENerator:RELStats?The tracking generator S21 Insertion Loss relative statistic measurement must be the active measurement (specified by :CONFigure:TGENerator RELStats). The current measurement can be queried using :CONFigure?
| Copyright 2011 Anritsu Company |
|
| Anritsu Company | |
| 1800-ANRITSU | |
| 10450-00034, Rev. A | |
| mmdtechpubs@anritsu.com |