Triggers a new adjacent channel power ratio measurement and returns the results: main channel power, lower adjacent and upper adjacent channel power, and lower alternate and upper alternate channel power. It is a combination of the commands :ABORT;:INITiate;:FETCh:ACLR?The ACLR measurement must be the active measurement (specified by :CONFigure:RF ACLR). The current measurement can be queried using :CONFigure?
Triggers a new channel power measurement and returns the results. It is a combination of the commands :ABORT;:INITiate;:FETCh:CHPower?The channel power measurement must be active. The current measurement can be queried using :CONFigure?
Triggers a new measurement and returns the active channel count. It is a combination of the commands :ABORT;:INITiate;:FETCh:DEMod:ACTChannels?
Triggers a new code domain power measurement and returns the results. It is a combination of the commands :ABORT;:INITiate;:FETCh:DEMod:CDPower?The code domain power measurement must be active. The current measurement can be queried using :CONFigure?
Triggers a new measurement and returns the carrier feed through results. It is a combination of the commands :ABORT;:INITiate;:FETCh:DEMod:CFTHrough?The carrier feed through measurement must be active. The current measurement can be queried using :CONFigure?
Triggers a new measurement and returns the EVM results. It is a combination of the commands :ABORT;:INITiate;:FETCh:DEMod:EVM?
Triggers a new measurement and returns the frequency error results. It is a combination of the commands :ABORT;:INITiate;:FETCh:DEMod:FERRor?The frequency error measurement must be active. The current measurement can be queried using :CONFigure?
Triggers a new measurement and returns the noise floor results. It is a combination of the commands :ABORT;:INITiate;:FETCh:DEMod:NFLoor?The noise floor measurement must be active. The current measurement can be queried using :CONFigure?
Triggers a new measurement and returns the channel count. It is a combination of the commands :ABORT;:INITiate;:FETCh:DEMod:NUMChannels?
Triggers a new measurement and returns the synch channel power results. It is a combination of the commands :ABORT;:INITiate;:FETCh:DEMod:SPOWer?The synch channel power measurement must be active. The current measurement can be queried using :CONFigure?
Triggers a new measurement and returns transmitter frequency results. It is a combination of the commands :ABORT;:INITiate;:FETCh:DEMod:TXFRequency?The carrier frequency measurement must be active. The current measurement can be queried using :CONFigure?
Triggers a new spectral emission mask measurement and returns the results: pass/fail status and template number. It is a combination of the commands :ABORT;:INITiate;:FETCh:EMISsion?The spectral emission mask measurement must be active. The current measurement can be queried using :CONFigure?
Triggers a new spectral emission mask measurement and returns the pass/fail results. It is a combination of the commands :ABORT;:INITiate; :FETCh:EMISsion:FAIL?The spectral emission mask measurement must be active. The current measurement can be queried using :CONFigure?
Triggers a new spectral emission mask measurement and returns the template number result. It is a combination of the commands :ABORT;:INITiate; :FETCh:EMISsion:TEMPlate?The spectral emission mask measurement must be active. The current measurement can be queried using :CONFigure?
Triggers a new occupied bandwidth measurement and returns the result. It is a combination of the commands :ABORT;:INITiate;:FETCh:OBWidth?The occupied bandwidth measurement must be active. The current measurement can be queried using :CONFigure?
Triggers a new over-the-air measurement and returns the result. It is a combination of the commands :ABORT;:INITiate;:FETCh:OTA?The over-the-air measurement must be active. The current measurement can be queried using :CONFigure?
Triggers a new PASS/FAIL measurement and returns the results. It is a combination of the commands :ABORT;:INITiate;:FETCh:PFail?
See :FETCh:PFail?Triggers a new measurement and returns the peak to average power ratio result. It is a combination of the commands :ABORT;:INITiate;:FETCh:PTAPower?The peak to average power measurement must be active. The current measurement can be queried using :CONFigure?
| Copyright 2011 Anritsu Company |
|
| Anritsu Company | |
| 1800-ANRITSU | |
| 10450-00034, Rev. A | |