Spectrum Master Programming Manual : EV‑DO Commands : :CALCulate Subsystem
 
:CALCulate Subsystem
The commands in this subsystem process data that has been collected via the CALCulate subsystem. Valid measurements with the use of markers are RF Measurement - Channel Spectrum and the Demodulator Measurement - CDP MAC.
:CALCulate:MARKer:AOFF
Title
Turn All Markers Off
Description
Turns off all markers.
Front Panel Access
Marker, All Markers Off
:CALCulate:MARKer{1|2|3|4|5|6}:Y?
Title
Marker Read Y Value
Description
Reads the current Y value for the specified marker. The units are the units of the y‑axis.
Default Unit
Current y‑axis unit
:CALCulate:MARKer{1|2|3|4|5|6}[:STATe] OFF|ON|0|1
:CALCulate:MARKer{1|2|3|4|5|6}[:STATe]?
Title
Marker State
Description
Sets the specified marker on/off.
Parameter
OFF|ON|0|1
Parameter Type
<boolean>
Default Value
OFF
Example
To turn off reference marker #1:
:CALCulate:MARKer1:STATe OFF
Front Panel Access
Marker, On/Off