Sets/Queries the relative location of the delta marker from the reference marker on the x‑axis. Note: The query value might not always match the set value since the instrument will round the set value based on the display pixel resolution.
In Channel Spectrum view, the x1 parameter is used to set the delta position. The x2 parameter is ignored. For example, :CALC:MARK1:DELT:X 2 MHz will set the delta value to 2 MHz. In Power vs. Time view, the x2 parameter is used to set the delta position.
The units must be specified (valid units are us, ms, s). The x1 parameter value is ignored but is required. For example, :CALC:MARK1:DELT:X 0,1 ms will set the delta value to 1 ms.
Parameters
<x1 parameter>,<x2 parameter>
Default Unit
Hz in RF Channel Spectrum view and microseconds in Power vs Time view.
Related Command
:CALCulate:MARKer1:X
Front Panel Access
Marker, Marker Select (M1), Marker State (Delta), (Use arrow keys or rotary knob.)
:CALCulate:MARKer1:DELTa:Y?
Title
Delta Marker 1 Read Y Value
Description
Reads the current absolute Y value for delta marker 1.
Sets/Queries the location of marker 1 on the x‑axis at the specified location.
In Channel Spectrum view, the x1 parameter is used to set the position. The x2 parameter is ignored. For example, :CALC:MARK1:X 756.24 MHz will set Marker 1 to 756.24 MHz.
In Power vs. Time view, the x2 parameter is used to set the position of the marker in time units.
The units must be specified (valid units are us, ms, s). The x1 parameter value is ignored but is required. For example, :CALC:MARK1:X 0,1 ms will set Marker 1 to 1 ms.
Parameters
<x1 parameter>,<x2 parameter>
Default Unit
Hz in RF Channel Spectrum view and microseconds in Power vs. Time view.
Front Panel Access
Marker, Marker Select [1/2/3/4/5/6] (use arrow keys or rotary knob)
Sets/Queries the relative location of the delta marker from the reference marker on the x‑axis. Note: The query value might not always match the set value since the instrument will round the set value based on the display pixel resolution.
In Channel Spectrum view, the x1 parameter is used to set the delta position. The x2 parameter is ignored. For example, :CALC:MARK2:DELT:X 2 MHz will set the Marker 2 delta value to 2 MHz.
In Power vs. Time view, the x2 parameter is used to set the delta position. The units must be specified (valid units are us, ms, s). The x1 parameter value is ignored but is required.
For example, :CALC:MARK2:DELT:X 0,1 ms will set the Marker 2 delta value to 1 ms.
Parameters
<x1 parameter>,<x2 parameter>
Default Unit
Hz in RF Channel Spectrum view and microseconds in Power vs. Time view.
Related Command
:CALCulate:MARKer2:X
Front Panel Access
Marker, Marker Select (M2), Marker State (Delta), (Use arrow keys or rotary knob.)
:CALCulate:MARKer2:DELTa:Y?
Title
Delta Marker 2 Read Y Value
Description
Reads the current absolute Y value for delta marker 2.
Sets/Queries the location of marker 2 on the x‑axis at the specified location.
In Channel Spectrum view, the x1 parameter is used to set the position. The x2 parameter is ignored. For example, :CALC:MARK2:X 756.24 MHz will set Marker 2 to 756.24 MHz.
In Power vs. Time view, the x2 parameter is used to set the position of the marker in time units. The units must be specified (valid units are us, ms, s). The x1 parameter value is ignored but is required. For example, :CALC:MARK2:X 0,1 ms will set Marker 2 to 1 ms.
Parameters
<x1 parameter>,<x2 parameter>
Default Unit
Hz in RF Channel Spectrum view and microseconds in Power vs. Time view.