:INITiate Subsystem
The commands in this subsystem control the triggering of measurements.
:INITiate:PIManalyzer:MEASure OFF|ON|0|1
Title
Trigger PIM Analyzer Measurement
Description
This command triggers the start of the PIM Master measurement to measure intermodulation distortion generated between the PIM Analyzer and the system under test. It works with any of the available measurement types: PIM vs. Time, DTP, Swept PIM. The measurement will continue until the defined test duration time has elapsed.
Sending this command with the OFF parameter or the 0 parameter cancels the measurement.
Parameter
OFF|ON|0|1
Front Panel Access
Measurements, Test (Measure underlined)
 
:INITiate:PIManalyzer:PVT:ALLPower:CAL
Title
PvT All Power Levels Calibration
Description
This command triggers the start of the PIM vs. Time calibration for all power levels.
Front Panel Access
Shift-Cal (2), Custom Calibrations, Start Cal