Parameter Name | Description |
---|---|
SN | Instrument serial # |
UNIT_NAME | Instrument name |
TYPE | The data type (Setup or Data). |
DESCR | Trace name |
DATE | Trace date/time |
BASE_VER | Base FW version |
APP_NAME | Application name |
APP_VER | Application FW version |
APP_MODE | Application Mode |
CHECKSUM | Checksum |
DIST_UNITS | Distance units |
AMPL_UNITS | y‑axis value units |
MEASUREMENT | Measurement |
1PORT_DOMAIN | 1‑Port Domain |
FREQ_START | Start Frequency |
FREQ_STOP | Stop Frequency |
DIST_START | Start distance |
DIST_STOP | Stop distance |
CAL_STATUS | Calibrate Status (On/Off) |
SWEEP_TIME | Sweep time |
SWEEP_TYPE | Sweep type (Single/Continuous) |
MARKER_SELECTED | The selected marker |
MARKER_TABLE | Marker table status (On/Off) |
TRACE_VIEW | Trace View (View/Blank) |
TRACE_STATE | Trace State (Write/Hold) |
WINDOWING | Windowing Type (Rectangular/Nominal Side Lobe/ Low Side Lobe/Minimum Side Lobe) |
CABLE | Cable index from the cable list |
PROP_VEL | Propagation velocity |
CABLE_LOSS | Cable Loss |
CW_STATUS | RF Immunity (On/Off) |
OUTPUT_POWER_LEVEL | Power Level (High/Low) |
CURRENT_SIGNAL_STD | Current signal standard |
RESOLUTION | Sweep Resolution (137/275/551) |
SCALE | Y‑axis scale |
RF_SOURCE_POWER_LEVEL | Source Power Level |
CAL_TEMP_WINDOW | Cal Temp window |
CAL_COEFFICIENT_PTR | Calibrate coefficient |
SMITH_CHART_TYPE | Smith chart type |
DISPLAY_CHANNELS | Display Channels |
ACTIVE_DISPLAY_CHANNEL | The current active display channel |
NUM_OF_CHANNELS | Channel number |
SEND_CAL_PROMPTS | Send Cal prompts |
SET_SWEEP_DATA_TYPE | Set sweep data type |
AVERAGING | Averaging |
DISP_CHANNELS | Display channels |
ACTIVE_DISP_CHANNEL | Active display channel |
DMAX | Dmax |
FAULT_RESOLUTION | Fault Resolution |
SUGGESTED_SPAN | Suggested span |
START_FREQ_STATUS | Start frequency status |
AVERAGING_FACTOR | Averaging Factor. |
AVERAGE_COUNT | Averaging count. |
SCALE_RESOLUTION_RL_DIST | S11 Log Magnitude Fault Location scale resolution |
SCALE_RESOLUTION_SWR | S11 VSWR scale resolution |
SCALE_RESOLUTION_SWR_DIST | S11 VSWR Fault Location scale resolution |
SCALE_RESOLUTION_CL | Cable loss Scale resolution |
SCALE_RESOLUTION_IL | IL scale resolution |
SCALE_RESOLUTION_IG | S21 Log Magnitude scale resolution |
SCALE_RESOLUTION_PHASE_S11 | S11 Phase scale resolution |
REFERENCE_VALUE_PHASE_S11 | S11 Phase reference value |
REFERENCE_LINE_PHASE_S11 | S11 Phase reference line |
RL_DIST_BOTTOM | DTF Return Loss Bottom Value |
SWR_DIST_TOP | DTF VSWR Top Value |
SWR_DIST_BOTTOM | DTF VSWR Bottom Value |
RL_MAG_TOP | Return Loss Top Value |
RL_MAG_BOTTOM | Return Loss Bottom Value |
SWR_MAG_TOP | VSWR Top Value |
SWR_MAG_BOTTOM | VSWR Bottom Value |
CL_MAG_TOP | Cable Loss Top Value |
CL_MAG_BOTTOM | Cable Loss Bottom Value |
S11_PHASE_TOP | 1‑Port Phase Top Value |
S11_PHASE_BOTTOM | 1‑Port Phase Bottom Value |
MKR_REF_FREQNx | Reference marker x frequency (where x is the marker number 0–5) |
MKR_REF_FLAGSx | Reference marker x flags: MKR_FLAG_ON_OFF: 0x00000001 MKR_FLAG_DELTA_MKR: 0x00000020 MKR_FLAG_DATA_INVALID: 0x00000040 MKR_FLAG_DATA_STALE: 0x00000080 MKR_FLAG_SELECTED: 0x00000100 MKR_FLAG_DELT_DISPL_PER_HZ: 0x00000800 MKR_FLAG_TRACE_A: 0x00001000 MKR_FLAG_TRACE_B: 0x00002000 MKR_FLAG_TRACE_MASK: 0x00007000 |
MKR_DLT_FREQNx | Delta marker x frequency (where x is the marker number 0–5) |
MKR_DLT_FLAGSx | Delta marker x flags: |
LIM_LFLAGS_UP-1 | Upper limit flags: LIMIT_FLAG_UPPER: 0x00000001 LIMIT_FLAG_ON: 0x00000004 LIMIT_FLAG_ALARM_ON: 0x00000002 LIMIT_FLAG_SEGMENTED: 0x00000020 LIMIT_FLAG_ALARM_EVENT: 0x00000040 LIMIT_FLAG_LEFT_OF_START_FREQ: 0x00000080 LIMIT_FLAG_RIGHT_OF_STOP_FREQ: 0x00000100 LIMIT_FLAG_MASK: 0x000007FF |
LIM_NUMPTS_UP-1 | Number of upper limit points |
LIM_CURFRQ_UP-1 | Upper limit current frequency |
LIM_CURMAG_UP-1 | Upper limit current magnitude |
LIM_PFLAGS_UPx | Upper limit x flags (where x is the limit point number starting with 0) |
LIM_FREQNC_UPx | Upper limit point x freq (where x is the limit point number starting with 0) |
LIM_MAGNTD_UPx | Upper limit point x parameter (where x is the limit point number starting with 0) |