PIM Master™ Passive Intermodulation Analyzer with Site Master™ Cable & Antenna Analyzer Option Programming Manual : Programming with SCPI : Parameter Names
 
Parameter Names
The following tables list the parameter options for the :TRACe:PREamble? command in each supported measurement mode.
Cable & Antenna Parameter Names
Available Parameters in Cable & Antenna Mode (1 of 4)
Parameter Name
Description
SN
Instrument serial #
UNIT_NAME
Instrument name
TYPE
The data type (Setup or Data).
DESCR
Trace name
DATE
Trace date/time
BASE_VER
Base FW version
APP_NAME
Application name
APP_VER
Application FW version
APP_MODE
Application Mode
CHECKSUM
Checksum
DIST_UNITS
Distance units
AMPL_UNITS
y‑axis value units
MEASUREMENT
Measurement
1PORT_DOMAIN
1‑Port Domain
FREQ_START
Start Frequency
FREQ_STOP
Stop Frequency
DIST_START
Start distance
DIST_STOP
Stop distance
CAL_STATUS
Calibrate Status (On/Off)
SWEEP_TIME
Sweep time
SWEEP_TYPE
Sweep type (Single/Continuous)
MARKER_SELECTED
The selected marker
MARKER_TABLE
Marker table status (On/Off)
TRACE_VIEW
Trace View (View/Blank)
TRACE_STATE
Trace State (Write/Hold)
WINDOWING
Windowing Type (Rectangular/Nominal Side Lobe/
Low Side Lobe/Minimum Side Lobe)
CABLE
Cable index from the cable list
PROP_VEL
Propagation velocity
CABLE_LOSS
Cable Loss
CW_STATUS
RF Immunity (On/Off)
OUTPUT_POWER_LEVEL
Power Level (High/Low)
CURRENT_SIGNAL_STD
Current signal standard
RESOLUTION
Sweep Resolution (137/275/551)
SCALE
Y‑axis scale
RF_SOURCE_POWER_LEVEL
Source Power Level
CAL_TEMP_WINDOW
Cal Temp window
CAL_COEFFICIENT_PTR
Calibrate coefficient
SMITH_CHART_TYPE
Smith chart type
DISPLAY_CHANNELS
Display Channels
ACTIVE_DISPLAY_CHANNEL
The current active display channel
NUM_OF_CHANNELS
Channel number
SEND_CAL_PROMPTS
Send Cal prompts
SET_SWEEP_DATA_TYPE
Set sweep data type
AVERAGING
Averaging
DISP_CHANNELS
Display channels
ACTIVE_DISP_CHANNEL
Active display channel
DMAX
Dmax
FAULT_RESOLUTION
Fault Resolution
SUGGESTED_SPAN
Suggested span
START_FREQ_STATUS
Start frequency status
AVERAGING_FACTOR
Averaging Factor.
AVERAGE_COUNT
Averaging count.
SCALE_RESOLUTION_RL_DIST
S11 Log Magnitude Fault Location scale resolution
SCALE_RESOLUTION_SWR
S11 VSWR scale resolution
SCALE_RESOLUTION_SWR_DIST
S11 VSWR Fault Location scale resolution
SCALE_RESOLUTION_CL
Cable loss Scale resolution
SCALE_RESOLUTION_IL
IL scale resolution
SCALE_RESOLUTION_IG
S21 Log Magnitude scale resolution
SCALE_RESOLUTION_PHASE_S11
S11 Phase scale resolution
REFERENCE_VALUE_PHASE_S11
S11 Phase reference value
REFERENCE_LINE_PHASE_S11
S11 Phase reference line
RL_DIST_BOTTOM
DTF Return Loss Bottom Value
SWR_DIST_TOP
DTF VSWR Top Value
SWR_DIST_BOTTOM
DTF VSWR Bottom Value
RL_MAG_TOP
Return Loss Top Value
RL_MAG_BOTTOM
Return Loss Bottom Value
SWR_MAG_TOP
VSWR Top Value
SWR_MAG_BOTTOM
VSWR Bottom Value
CL_MAG_TOP
Cable Loss Top Value
CL_MAG_BOTTOM
Cable Loss Bottom Value
S11_PHASE_TOP
1‑Port Phase Top Value
S11_PHASE_BOTTOM
1‑Port Phase Bottom Value
MKR_REF_FREQNx
Reference marker x frequency (where x is the marker number 0–5)
MKR_REF_FLAGSx
Reference marker x flags:
MKR_FLAG_ON_OFF: 0x00000001
MKR_FLAG_DELTA_MKR: 0x00000020
MKR_FLAG_DATA_INVALID: 0x00000040
MKR_FLAG_DATA_STALE: 0x00000080
MKR_FLAG_SELECTED: 0x00000100
MKR_FLAG_DELT_DISPL_PER_HZ: 0x00000800
MKR_FLAG_TRACE_A: 0x00001000
MKR_FLAG_TRACE_B: 0x00002000
MKR_FLAG_TRACE_MASK: 0x00007000
MKR_DLT_FREQNx
Delta marker x frequency (where x is the marker number 0–5)
MKR_DLT_FLAGSx
Delta marker x flags:
LIM_LFLAGS_UP-1
Upper limit flags:
LIMIT_FLAG_UPPER: 0x00000001
LIMIT_FLAG_ON: 0x00000004
LIMIT_FLAG_ALARM_ON: 0x00000002
LIMIT_FLAG_SEGMENTED: 0x00000020
LIMIT_FLAG_ALARM_EVENT: 0x00000040
LIMIT_FLAG_LEFT_OF_START_FREQ: 0x00000080
LIMIT_FLAG_RIGHT_OF_STOP_FREQ: 0x00000100
LIMIT_FLAG_MASK: 0x000007FF
LIM_NUMPTS_UP-1
Number of upper limit points
LIM_CURFRQ_UP-1
Upper limit current frequency
LIM_CURMAG_UP-1
Upper limit current magnitude
LIM_PFLAGS_UPx
Upper limit x flags (where x is the limit point number starting with 0)
LIM_FREQNC_UPx
Upper limit point x freq (where x is the limit point number starting with 0)
LIM_MAGNTD_UPx
Upper limit point x parameter (where x is the limit point number starting with 0)