All modulation parameters are described in detail in the M280005A User’s Guide (10580-00475).
ModulationTypeList
Description
Returns a list of supported modulation types.
Commamnd Type
Get Only
Return Type
String
ModulationType
Command Type
Set and Get
Return Type
String
FrameFormatted
Command Type
Set and Get
Return Type
Boolean
ModulationIndex
Command Type
Set and Get
Return Type
Single
APSK_RingRatio_R2toR1
Command Type
Set and Get
Return Type
Single
APSK_RingRatio_R3toR1
Command Type
Set and Get
Return Type
Single
ModulationIndexSwitch
Command Type
Set and Get
Return Type
Boolean
MaxFreqDeviation
Command Type
Set and Get
Return Type
Single
MaxFreqDeviationSwitch
Command Type
Set and Get
Return Type
Boolean
SymbolRate
Command Type
Set and Get
Return Type
Single
SamplingRate
Command Type
Set and Get
Return Type
Single
SpanUp
Command Type
Set and Get
Return Type
Boolean
CaptureOverSampling
Command Type
Set and Get
Return Type
Integer
CaptureInterval
Command Type
Set and Get
Return Type
eAnaCaptureInterval
MappingNumberOfSymbols
Command Type
Set and Get
Return Type
Integer
MappingNumberOfBits
Command Type
Set and Get
Return Type
Integer
MappingData
Command Type
Set and Get
Return Type
String
MappingFilename
Command Type
Set and Get
Return Type
String
FilterMeas1stName
Command Type
Set and Get
Return Type
String
FilterRef1stName
Command Type
Set and Get
Return Type
String
FilterMeas2ndName
Command Type
Set and Get
Return Type
String
FilterRef2ndName
Command Type
Set and Get
Return Type
String
FilterRollOff
Command Type
Set and Get
Return Type
Single
FilterRollOff2nd
Command Type
Set and Get
Return Type
Single
SlotsPerFrame
Command Type
Set and Get
Return Type
Integer
SlotOn_01
Command Type
Set and Get
Return Type
Boolean
SlotOn_02
Command Type
Set and Get
Return Type
Boolean
SlotOn_03
Command Type
Set and Get
Return Type
Boolean
SlotOn_04
Command Type
Set and Get
Return Type
Boolean
SlotOn_05
Command Type
Set and Get
Return Type
Boolean
SlotOn_06
Command Type
Set and Get
Return Type
Boolean
SlotOn_07
Command Type
Set and Get
Return Type
Boolean
SlotOn_08
Command Type
Set and Get
Return Type
Boolean
SlotOn_09
Command Type
Set and Get
Return Type
Boolean
SlotOn_10
Command Type
Set and Get
Return Type
Boolean
SlotOn_11
Command Type
Set and Get
Return Type
Boolean
SlotOn_12
Command Type
Set and Get
Return Type
Boolean
SlotOn_13
Command Type
Set and Get
Return Type
Boolean
SlotOn_14
Command Type
Set and Get
Return Type
Boolean
SlotOn_15
Command Type
Set and Get
Return Type
Boolean
SlotOn_16
Command Type
Set and Get
Return Type
Boolean
SlotOn_17
Command Type
Set and Get
Return Type
Boolean
SlotOn_18
Command Type
Set and Get
Return Type
Boolean
SlotOn_19
Command Type
Set and Get
Return Type
Boolean
SlotOn_20
Command Type
Set and Get
Return Type
Boolean
SlotLength
Command Type
Set and Get
Return Type
Integer
MeasurementOffset
Command Type
Set and Get
Return Type
Integer
MeasurementInterval
Command Type
Set and Get
Return Type
Integer
SyncWordSearchOn
Command Type
Set and Get
Return Type
Boolean
BurstSearchOn
Command Type
Set and Get
Return Type
Boolean
Enable2ndSyncWord
Command Type
Set and Get
Return Type
Boolean
First_SearchSlot
Command Type
Set and Get
Return Type
Integer
First_SyncWordLength
Command Type
Set and Get
Return Type
Integer
First_SyncWord
Command Type
Set and Get
Return Type
ULong
First_SyncWordOffset
Command Type
Set and Get
Return Type
Integer
Second_SearchSlot
Command Type
Set and Get
Return Type
Integer
Second_SyncWordLength
Command Type
Set and Get
Return Type
Integer
Second_SyncWord
Command Type
Set and Get
Return Type
ULong
Second_SyncWordOffset
Command Type
Set and Get
Return Type
Integer
DeviationCalculation
Command Type
Set and Get
Return Type
eFSKDevMeasSw
DeviationRmsRef
Command Type
Set and Get
Return Type
eFSKDevRmsRef
Convergence
Command Type
Set and Get
Return Type
Single
FilterLength
Command Type
Set and Get
Return Type
Integer
Adaptive
Command Type
Set and Get
Return Type
eEquOperationMode
MethodOfSymbolRateError
Command Type
Set and Get
Return Type
eSymRateErrMeasMethod
HcpmDecodeMethod
Command Type
Set and Get
Return Type
eHcpmDecodeMethod
OriginOffsetCancel
Command Type
Set and Get
Return Type
Boolean
OriginOffsetRef
Command Type
Set and Get
Return Type
eOORefPwr
DroopCancel
Command Type
Set and Get
Return Type
Boolean
EVMReference
Command Type
Set and Get
Return Type
eEvmReference
MeasurementFilters
(Optional ModType, Optional Number) As String()
Command Type
Get Only
Return Type
String()
Parameters
ModType: eDigModFormat (Default: –1)
Number
Integer (Default: –1)
Description
Returns a string array containing the valid measurement filter names. If ModType is -1, then the list is complete for all modulation types. Otherwise it is only the valid filters for the given modulation type. Number designations the 1st or 2nd measurement filter.
ReadOnly ReferenceFilters(
Optional ModType, (Optional Number) As String()
Description
Returns a string array containing the valid reference filter names. If ModType is -1, then the list is complete for all modulation types. Otherwise it is only the valid filters for the given modulation type. Number designations the 1st or 2nd reference filter