Remote Spectrum Monitor™ MS27201A User Guide : 5GNR Measurements
 
5GNR Measurements
 
Introduction
RF Measurements
Modulation Measurements
Selecting the Analyzer
Main Menu
Using Menus
Setting Frequency and Band Parameters
Configuring the Band
FREQUENCY Menu
BAND CONFIG Menu
GESTURES Menu
Setting Amplitude
Setting Amplitude Parameters
Reference Level Offset for External Loss or External Gain
Attenuator Functions
Indications of Excessive Signal Level
AMPLITUDE Menu
Setting Bandwidth Parameters
BANDWIDTH Menu
Setting Trace Parameters
TRACE Menu
Setting Sweep Parameters
SWEEP Menu – Summary Measurements
SWEEP Menu – RF Measurements
Gated Sweep (Option 90)
GATED SWEEP Menu
POWER VS. TIME Display
Setting Up Markers
Placing a Normal Marker
Placing a Fixed Marker
Placing a Delta Marker
MARKER Menu
MARKER PEAK SEARCH Menu
Marker Functions
Marker Table
5GNR Measurement Setup
MEASURE Menu (5GNR)
5GNR Summary and Multi PCI
5GNR Summary Multi Beam View
5GNR Summary Single Beam View
5GNR Multi PCI Scanner View
5GNR Multi PCI Table View
SETUP Menu (5GNR Summary/Multi PCI)
Status Panel (5GNR Summary/Multi PCI)
5GNR Channel Power
SETUP Menu (5GNR Channel Power)
Status Panel (5GNR Channel Power)
5GNR Occupied Bandwidth
SETUP Menu (5GNR OBW)
Status Panel (5GNR OBW)
5GNR EIRP
EIRP Normal View
EIRP Normal View
SETUP Menu (5GNR EIRP)
Status Panel (5GNR EIRP)
5GNR Carrier Aggregation
5GNR Carrier Aggregation View
SETUP Menu (5GNR Carrier Aggregation)
Status Panel (5GNR Carrier Aggregation)
5GNR Constellation
SETUP Menu (5GNR Constellation)
Status Panel (5GNR Constellation)
Presetting the Analyzer
PRESET Menu
Saving and Recalling Measurements
Saving a Measurement
Recalling a Measurement
FILE Menu
Introduction
This chapter gives a brief overview of the Anritsu Remote Spectrum Monitor 5GNR analyzer and its measurement capabilities. The purpose of this chapter is to provide a starting point for making 5GNR measurements. This chapter describes measurement setup, including selecting the analyzer and setting up frequency, bandwidth, amplitude, span, and markers. After measurements are taken, refer to Saving and Recalling Measurements for a description of saving, recalling, and managing measurement files. For detailed information about other specific measurements, refer to the appropriate chapter in this guide.
A basic understanding of the measurement concepts presented in Spectrum Monitor Measurements is recommended before performing the procedures in this chapter. 5GNR measurements include the use of additional functions beyond frequency, span, amplitude, and marker functions. Setting Frequency and Band Parameters through Setting Up Markers explain general setup procedures and settings. 5GNR Measurement Setup through 5GNR Constellation provide example 5GNR measurements that are available in the 5GNR analyzer.
5GNR measurement setups typically conform to the 3GPP and device manufacturer standards. They can be configured manually or based on the band selection and accompanying ARFCN and GSCN assignments. Remote Spectrum Monitor is designed to make setting up your measurement as easy as possible. Simply refer to the specification for the measurement and base station settings that you are testing, select the measurement, and enter the base station measurement setup parameters.
The 5GNR signal analyzer offers the following measurement options:
RF Measurements
The following display types are provided for RF measurements:
5GNR Channel Power
5GNR Occupied Bandwidth
Gated Sweep (Option 90) and POWER VS. TIME Display
5GNR EIRP
Modulation Measurements
LTE modulation measurements for both frequency division duplex (FDD) and time division duplex (TDD) signals can be viewed in:
5GNR Summary and Multi PCI
5GNR Carrier Aggregation
5GNR Constellation