Remote Spectrum Monitor™ MS27201A User Guide : LTE Measurements : LTE Frame Power
 
LTE Frame Power
LTE communication systems carry data in frames and sub-frames. The LTE frame power measurement provides a power vs. time view of the frame, sub-frames, and slots in an LTE signal. Two types of LTE frame structures are used:
Type 1 is used in LTE frequency division duplex (FDD) and has an overall length of 10 ms with 10 sub-frames and a total of 20 individual slots. FDD uses different uplink and downlink frequencies.
Type 2 is used in LTE time division duplex (TDD) and has an overall length of 10 ms with two half frames (each 5 ms long) that are divided into 5 sub-frames (each 1 ms long). TDD uses the same uplink and downlink frequency that is separated in time.
A frame power measurement using time domain duplex TDD) type is shown in Figure: LTE Channel Spectrum (Occupied Bandwidth) Measurement. The example is showing the complete 10 ms frame power vs. time.
LTE Frame Power TDD Measurement

1. LTE Frame Power Status Panel: Each measurement features a unique status panel that displays settings and information relevant to the current measurement and view settings. This panel provides quick access to the measurement frequency and band configuration. See Status Panel (LTE Frame Power).
2. PCI SUMMARY: This area shows the physical cell ID, including the sector ID, cell group number, frequency error, time offset, cyclic prefix, and sync status. Sync status can indicate if there is a PSS or SSS failure, a Full Sync, or an Unknown condition. Also noted is the instrument’s reference clock accuracy of Internal, External, or GPS high accuracy (requires GPS).
3. SETUP Menu: The frame power measurement settings are configured in the SETUP menu. See SETUP Menu (LTE Frame Power).
4. Frame Power vs. Time Display: Shows trace data of the total frame or sub-frame power measurement in the time domain.
5. Sub-Frame Power Summary: This area shows the frame power measurement summary data. Power measurements are expressed in dBm.
The power of each sub-frame, each of two slots in the sub-frame, and the total frame power is measured.
For TDD duplex type, the downlink pilot time slot (DwPTS), uplink pilot time slot (UpPTS), and transmit off power is measured. (see notes below)
Note 
DwPTS carries reference signals, primary synchronization signal, control information, and data.
UpPTS is typically the sounding reference signal transmission from user equipment and is used for the random access channel to setup and synchronize the transmission.
SETUP Menu (LTE Frame Power)
The Frame Power SETUP menu is available in MEASURE > MEASUREMENT > Frame Power > SETUP. Once the frame power measurement is selected, the SETUP menu can be quickly accessed by tapping on the summary display area below the trace display.
LTE SETUP Menu (Frame Power)
-
 
ANALYSIS
Selects the analysis time of full frame, sub-frame, or individual slot.
SSF CONFIG
Selects the special sub-frame configuration as Auto or one of 10 manual configurations. The slots/sub-frame configuration choices are outlined below:
0: 3 downlink, 10 guard period, 1 uplink
1: 9 downlink, 4 guard period, 1 uplink
2: 0 downlink, 3 guard period, 1 uplink
3: 11 downlink, 2 guard period, 1 uplink
4: 12 downlink, 1 guard period, 1 uplink
5: 3 downlink, 9 guard period, 2 uplink
6: 9 downlink, 3 guard period, 2 uplink
7: 10 downlink, 2 guard period, 2 uplink
8: 11 downlink, 1 guard period, 2 uplink
9: 6 downlink, 6 guard period, 2 uplink
SUB-FRAME
Enables limit checking at the specified frequency. The limit test results show as a green PASS or a red FAIL in the measurement table.
SLOT
Select the measurement method to be PERCENT (%) or X (dB).
ANTENNA
Sets the MIMO antenna number (0 to 3, or AUTO) to use during a measurement. AUTO will use the antenna with the highest received signal power.
CYCLIC PREFIX
Sets the cyclic prefix (or guard time interval) to Normal, Extended, or Auto. The cyclic prefix is a duplication of a fraction of the symbol end. This setting affects the OFDM symbol sensitivity to time dispersion.
DUPLEX TYPE
Selects either frequency division duplex (FDD) or time division duplex (TDD).
UL/DL CONFIG
Available only in TDD duplex type. Sets the uplink/downlink (UL/DL) configuration, or Frame Format. This selection determines which sub-frames are uplink sub-frames and which are downlink sub-frames, and where the transitions between uplink and downlink sub-frames occur.
NG: Selects the NG parameter of 1/6, 1/2, 1, or 2. NG is a parameter that determines the number of PHICH (Physical Hybrid ARQ Indicator Channel) groups in an LTE sub-frame (this number is constant for all sub-frames).
PRESET SETUP
Presets the SETUP menu to default settings.
 
Status Panel (LTE Frame Power)
The status panels illustrated in this section are unique to the current analyzer and to the particular measurement and view that is selected.
Figure: Status Panel (LTE Channel Spectrum Measurement) shows the LTE status panel that covers the LTE Frame Power measurement.
Status Panel (LTE Frame Power Measurement) 
 
MIMO ANTENNAS: Toggles the current MIMO antenna setting between AUTO or to select one of the available antennas. When a single antenna is selected, a blue underscore will appear below the antenna icon. The antenna icon is highlighted green when receiving a signal.
NG: Selects the NG parameter of 1/6, 1/2, 1, or 2. NG is a parameter that determines the number of PHICH (Physical Hybrid ARQ Indicator Channel) groups in an LTE sub-frame (this number is constant for all sub-frames).
SWEEP: Toggles the current sweep setting between continuously or sweep once.
SWEEP ONCE
When sweep is set to single sweep, SWEEP ONCE updates the measurement display. Data continues to be captured in the background.
CHANNEL BW
Sets the measurement channel bandwidth. The available bandwidth settings depend on the selected band and bandwidth option installed in the instrument. Refer to Options Settings.
CENTER FREQUENCY
Sets the center frequency of the measurement channel.
DETECTOR TYPE
Selects one of three detector types. Several detection methods tailor the function of the instrument to meet specific measurement requirements. There are often more measurement points across the screen than display points. The various detection methods are different ways of dealing with how measurement points will be shown at each display point (see Trace Detector Types).
Peak: This method causes the highest amplitude measurement point to be shown for each display point, assuring that a narrow peak is not missed.
RMS/Avg: In the default case, when the VBW/AVERAGE type is set to Linear, this method detects the average power of measurement points that go into the display point. When VBW/AVERAGE type is set to Log, the traditional average of log (power), such as dBm, is displayed for the detector, as well as for VBW and trace average.
Negative: This method causes the lowest amplitude measurement point to be shown for each display point. This method is also useful when looking at modulated signals, to see if some frequencies are not being used.
Sample: Shows the transient amplitude of the center of sampled data for each display point. This method is useful when measuring low-level signals and noise measurements. Only available in zero span and RSSI measurements.
FREQ REFERENCE
Indicates the current frequency reference source of Internal, External, or GPS Hi Accuracy (requires GPS). The instrument automatically selects the frequency reference in the following order of priority: external, GPS, then the internal time base.