APPLICATION Menu Variants
The number of buttons present and their names depends on the VNA instrument model and the equipped options.
APPLICATION Menu
Previous
• MAIN MENU
Navigation
• MAIN | Application | APPLICATION
Button Availability and Naming
• The buttons present and their names vary depending on the VNA model number and the installed options as shown in the table below.
APPLICATION Menu Variants – VNA Models – Equipped Options
VNA
Model
All MS4640A VNAs
MS4642A, MS4644A, MS4645A VNAs
MS4647A VNA
Equipped
Options
No 0071
0072, 0413
007, 041,
082/0834
007, 041
007, 041,
082/083
007, 041,
080/0815
Instrument Mode Buttons
T/R6
T/R
T/R
T/R
T/R
T/R
–
Noise
Figure7
Noise
Figure
Noise
Figure
Noise
Figure
Noise
Figure
Receiver Configuration Buttons
Standard
Standard
Standard
Standard
Standard
Standard
–
Multiple Source
Multiple Source
Multiple Source
Multiple Source
Multiple Source
–
mmWave
(3738 Test Set)
mmWave
(3738 Test Set)
–
–
–
–
–
–
BB/mmWave
(3738 Test Set)
BB/mmWave (3738 Test Set)
BB/mmWave
(3738 Test Set)
–
–
mmWave (3739 Test Set)
–
mmWave (3739 Test Set)
–
–
–
–
–
–
BB/mmWave (3739 Test Set)
Setup Buttons
–
Multiple Source Setup
Multiple Source Setup
Multiple Source Setup
Multiple Source Setup
Multiple Source Setup
–
mmWave
(3738 Setup)
mmWave
(3738 Setup)
–
–
–
–
–
–
BB/mmWave
(3738 Setup)
BB/mmWave (3738 Setup)
BB/mmWave (3738 Setup)
–
Noise Figure Setup8
Noise Figure Setup
Noise Figure Setup
Noise Figure Setup
Noise Figure Setup
–
–
mmWave (3739 Setup)
–
mmWave (3739 Setup)
–
–
–
–
–
–
BB/mmWave
(3739 Setup)
–
Mixer Setup
(Active Channel)9
Mixer Setup
(Active Channel)
Mixer Setup
(Active Channel)
Mixer Setup
(Active Channel)
Mixer Setup
(Active Channel)
–
Mixer Setup (Multi-Channel)
Mixer Setup (Multi-Channel)
Mixer Setup (Multi-Channel)
Mixer Setup (Multi-Channel)
Mixer Setup (Multi-Channel)
NxN
NxN
NxN
NxN
NxN
NxN

1 Option 007 – Receiver Offset is not installed.

2 Option 007 is installed.

3 Option 041 – Noise Figure. Requires front/rear panel access loops from Option 051, 061, or 062.

4 Option 082/083 – Millimeter-Wave connectivity. Use 082 for VNAs without 051, 061, or 062. Use 083 for VNAs with 051, 061, or 062. For MS4647A VNAs only, if 082/083 is equipped, Option 080/081 cannot be equipped.

5 Option 080/081 – Broadband/Millimeter-Wave connectivity. For MS4647A VNAs only. Use 080 for 47A VNAs without 051, 061, or 062. Use 081 for 47A VNAs with 051, 061, or 062. If 080/081 is equipped, Option 082/083 cannot be equipped.

6 Transmission/Reflection

7 Requires Option 041 and Option 051, 061, or 062. If not equipped, Noise Figure and Noise Figure Setup buttons are not present.

8 Noise Figure Setup button is only available if Noise Figure mode button (above) is selected.

9 The Mixer Setup (Active Channel) and Mixer Setup (Multi-Channels) buttons are not present if the instrument is in 4-Port Mode.