VectorStar™ MS4640A Series Microwave Vector Network Analyzers : Scale Menus : SCALE Magnitude Menus
 
SCALE Magnitude Menus
 
SCALE Log Magnitude Menu
Menu Identification
The appearance and button availability of the SCALE menu depends on the settings on the DISPLAY menu.
Consult the section above for SCALE menu identification and prerequisites.
Scale Menus Appearance, Common Buttons, and Units
Previous
MAIN MENU
Navigation
MAIN | Scale | SCALE
 
SCALE Log Magnitude Menu 
SCALE (Log Magnitude) Menu
This menu is available when TRACE FORMAT is set to Log Magnitude. Button units are set to:
Button Units: dB
 
Resolution (dB/Div)
Select displays the Resolution (dB) toolbar with units in dB per division.
Resolution (dB/Div) Field Toolbar
Reference Value (dB)
Select displays the Reference Value (dB) toolbar.
Reference Value (dB) Field Toolbar
Reference Position (Number)
Select displays the Reference Position toolbar.
Reference Position (Number) Field Toolbar
 
Additional Common Buttons
 
 
SCALE Linear Magnitude Menu
Menu Identification
The appearance and button availability of the SCALE menu depends on the settings on the DISPLAY menu. Consult the section above for SCALE menu identification and prerequisites.
Scale Menus Appearance, Common Buttons, and Units
Previous
MAIN MENU
Navigation
MAIN | Scale | SCALE
 
SCALE Linear Magnitude Menu 
SCALE (Linear Magnitude) Menu
This menu is available when TRACE FORMAT is set to Linear Magnitude. Button units are set to:
Button Units: U (Units)
 
Resolution (Units/Div)
Select displays the Resolution (Units/Division) toolbar with units of units per division.
Resolution (Units/Div) Field Toolbar
Reference Value (Units)
Select displays the Reference Value (Units) toolbar.
Reference Value (Units) Field Toolbar
Reference Position (Number)
Select displays the Reference Position toolbar.
Reference Position (Number) Field Toolbar
 
Additional Common Buttons
 
 
SCALE Impedance Magnitude Menu
Menu Identification
The appearance and button availability of the SCALE menu depends on the settings on the DISPLAY menu. Consult the section above for SCALE menu identification and prerequisites.
Scale Menus Appearance, Common Buttons, and Units
Previous
MAIN MENU
Navigation
MAIN | Scale | SCALE
 
SCALE Impedance Magnitude Menu 
SCALE (Impedance Magnitude) Menu
This menu is available when TRACE FORMAT is set to Impedance - Magnitude. Button units are set to:
Button Units: Ω (Ohms)
 
Resolution (Ohms/Div)
Select displays the Resolution (Ohms/Division) toolbar with units in Ohms per division.
Resolution (Ohms/Div) Field Toolbar
Reference Value (Ohms)
Select displays the Reference Value (Ohms) toolbar with units in Ohms.
Reference Value (Ohms) Field Toolbar
Reference Position (Number)
Select allows the user to define a reference position and displays the Reference Position field toolbar.
Reference Position (Number) Field Toolbar
 
Additional Common Buttons