VectorStar™ MS4640A Series Microwave Vector Network Analyzers : System Menus : Network Interface Menus and Dialog Boxes
 
Network Interface Menus and Dialog Boxes
 
NETWORK INTERF. Menu
Full Name
NETWORK INTERFACE Menu
Previous
SYSTEM Menu
Navigation
MAIN | System | SYSTEM | Network Interface | NETWORK INTERF.
 
NETWORK INTERF. (NETWORK INTERFACE) Menu
 
 
IP Address
A read-only display. Shows the IP address of the instrument.
Hardware Address
A read-only display. Shows the internal network interface card hardware address.
Subnet Mask
A read-only display. Shows the network subnet mask value.
Default Gateway
A read-only display. Shows the network default gateway address.
TCP Port Number
A read-only display. Shows the network TCP port number.
USB Vendor ID
A read-only display. Shows the USB Port vendor identification number.
USB Product ID
A read-only display. Shows the USB product identification number.
USB Serial Number
A read-only display. Shows the USB serial number.
Network Connections
Select displays the Network Connections dialog box which is part of the Microsoft Operating System.
NETWORK CONNECTIONS Dialog Box
 
NETWORK CONNECTIONS Dialog Box
Previous
NETWORK INTERF. Menu
Navigation
MAIN | System | SYSTEM | Network Interface | NETWORK INTERF. | Network Connections | NETWORK CONNECTIONS Dialog Box
 
NETWORK CONNECTIONS Dialog Box
 
SELF TEST Dialog Box
Previous
SYSTEM Menu
Navigation
MAIN | System | SYSTEM | Diagnostics | DIAGNOSTICS | Self-Test | SELF TEST Dialog Box
 
SELF TEST Dialog Box
1. SELF TEST Dialog Box – Test Not Started at left.
2. SELF TEST Dialog Box – Test Passed at right.
 
Instructions
1. Select any combination of tests from the available check boxes:
Source
Analog IF
RF Deck Ctrl
DSP/PV
2. The Select All button selects all tests. The Clear All button de-selects all tests.
3. Once selections are made, click Start to run the tests. Click Abort to cancel in-process tests.
4. Test results are displayed in the Self Test Message area.
5. A normal message is Self Test Passed.
6. Click Print to print to the local printer through an open Print dialog box. Click Save As to save as a Self Test Result TXT file typically located in C:\AnritsuVNA\Data. Click Close to close the dialog box.
 
 
EVENT VIEWER Dialog Box
Previous
SYSTEM Menu
Navigation
MAIN | System | SYSTEM | Event Log | EVENT VIEWER Dialog Box
 
EVENT VIEWER Dialog Box
 
Instructions
Options on the menu bar are:
File
Options: Displays the Options dialog box with additional system functions.
Exit: Closes the dialog box and returns to the Diagnostics menu
Action
Connect to another computer
Open log file
Export list
Help
View
Add/Remove columns
Customize
Help
Help Topics
About Microsoft Management Console
About Event Viewer
 
 
REAR PANEL OUT. Menu
Full Name
REAR PANEL OUTPUT Menu
Previous
SYSTEM Menu
Navigation
MAIN | System | SYSTEM | Rear Panel Output | REAR PANEL OUT.
 
REAR PANEL OUT. (REAR PANEL OUTPUT) Menu
 
 
Output Voltage
Select toggles rear panel output voltage off and on.
Output Mode Button Selection Group
The Horizontal, Driven Port, and TTL Output buttons form a three (3) button selection group where the selection of any one button de-selects the other two buttons.
Horizontal Output Mode
The horizontal output mode sets the condition of the sweep independent of the port sweep voltage that corresponds to the start and stop sweep limits. The values are edited in the dialog box available from the Edit Output Mode button below.
Selecting the Horizontal button de-selects Driven Port and TTL Port.
Driven Port Output Mode
The driven port output mode assigns the voltage setting to whichever port is set as the driven port. The values are edited in the dialog box available from the Edit Output Mode button below.
Selecting the Driven Port button de-selects Horizontal and TTL Port.
TTL Output Mode
The TTL (Transistor-Transistor-Logic) button sets the voltage output to either pulse or level TTL. The values are edited in the dialog box available from the Edit Output Mode button below.
Selecting the TTL Output Mode button de-selects Horizontal and Driven Port Output.
Edit Output Mode
Select displays the Edit Rear Panel Output Mode dialog box.
EDIT REAR PANEL OUTPUT MODE Dialog Box
 
EDIT REAR PANEL OUTPUT MODE Dialog Box
Previous
REAR PANEL OUT. Menu
Navigation
MAIN | System | SYSTEM | Rear Panel Output | REAR PANEL OUT. | Edit Output Mode | EDIT REAR PANEL OUTPUT MODE Dialog Box
 
EDIT REAR PANEL OUTPUT MODE Dialog Box
 
Instructions
Use the dialog box for settings of horizontal voltage, driven port voltage, and TTL output voltage levels.
Horizontal Voltage
Start (V). Selectable range from –10.000 to 0.000 to +10.000 V.
Stop (V). Selectable range from –10.000 to 0.000 to +10.000 V.
Driven Port
Set Output Voltage
Port 1 (V). Selectable range from –10.000 to 0.000 to +10.000 V.
Port 2 (V). Selectable range from –10.000 to 0.000 to +10.000 V.
TTL Output
Set Output Level
Port 1. Selectable options of High, Low, High Pulse, or Low Pulse.
Port 2. Selectable options of High, Low, High Pulse, or Low Pulse.
If High or Low Pulse selected, Pulse Width (ms) becomes available.
 
DIAGNOSTICS ACCESS Dialog Box
Previous
SYSTEM Menu
Navigation
MAIN | System | SYSTEM | Diagnostics | DIAGNOSTICS ACCESS Dialog Box
 
DIAGNOSTICS ACCESS Dialog Box
 
Instructions
An instrument-specific password is required to enter the DIAGNOSTICS ACCESS dialog box.
Contact Anritsu Customer Service before using this dialog box.