Slot Selection: Opens the Slot Selection Menu. Press this submenu key to open the Slot Selection list box. Use the arrow keys or the rotary knob to highlight Auto or one of the six slots. If Auto is selected, then the active slot is automatically detected. Press the Enter key to select. Trigger: Opens the Trigger Menu. Press this submenu key to list the Trigger menu, to set up the trigger parameters, and to set up the Tau Offset. Uplink Switch Point: Press this submenu key to set an uplink switch point. This is the slot number of the last uplink timeslot. Slots from the next timeslot to the end of the sub‑frame are considered downlink. The default value is 3. The range of values are 0 through 6, where 0 is no uplink. SYNC‑DL Code: Opens the SYNC‑DL Code Menu. Press this submenu key to open the SYNC‑DL Code list box. Use the Up/Down arrow keys or the rotary knob to highlight Auto or 0 through 31 and press Enter. If Auto is selected, then the active SYNC‑DL code is displayed. Scrambling Midamble Code: Opens the Scrambling Midamble Menu. Press this submenu key to open the Scrambling/Midamble Code list box. Use the Up/Down arrow keys or the rotary knob to highlight Auto or 0 through 127 and press Enter. If Auto is selected, the active Scrambling/Midamble code is displayed. Max Users: Opens the Max Users Menu. Press this submenu key to open the Maximum Users window. Use the Up/Down arrow keys or the rotary knob to highlight Auto or 2 through 16 and press Enter. If Auto is selected, then the maximum number of users is listed. Meas Speed: Press this submenu key to toggle the desired scan speeds: Fast, Norm, and Slow. The active state is underlined on the face of the virtual submenu key. More: Opens the Advanced Settings Menu. |