Backhaul Analyzer for Anritsu’s RF and Microwave Handheld Instruments : T1/FT1 Analyzer (Option 51 or 54)   : Measurements Menu : VF Menu
  
VF Menu
Key Sequence: Measurements > VF
VF Menu
Transmit
This submenu key toggles Transmit OFF and ON.
Channel #
This submenu key opens a dialog box to select a channel value from 1 (minimum) to 24 (maximum). Use the arrow keys, the rotary knob, or the numeric keys to enter a value, and then press Enter to continue, or press Esc to abort.
Tx Frequency
This submenu key opens a dialog box to select a frequency from 100 Hz (minimum) to 3000 Hz (maximum). Use the numeric keys to enter a value, or use the arrow keys or the rotary knob to select a default value, and then press Enter to continue, or press Esc to abort.
Tx Level
This submenu key opens a dialog box to select a Tx Level from – 30 dBm (minimum) to 0 dBm (maximum). Use the arrow keys, the rotary knob, or the numeric keys to enter a value, and then press Enter to continue, or press Esc to abort.
Volume
This submenu key opens a dialog box to set the volume from 0 (minimum) to 90 (maximum). Use the arrow keys, the rotary knob, or the numeric keys to enter a value in increments of 5, and then press Enter to continue, or press Esc to abort.
Audio
This submenu key toggles Audio OFF and ON.
Clear History
Press this submenu key to clear any red History indicators in the yellow‑highlighted, upper portion of the measurement display.
Back