Backhaul Analyzer Measurement Guide : E1 Analyzer (Option 52 or 55) : BERT Measurement Setup Procedure : BERT Table Display Setup
 
BERT Table Display Setup
1. Press the Measurements main menu key to activate the Measurements menu.
2. Press the BERT submenu key to activate the BERT menu.
3. Press the Table submenu key to display the measurements in the table format.
4. Press the Start/Stop main menu key to start and stop the measurement.
Note 
The pass/fail indicators are updated continuously even when measurements are stopped.
5. If the results are okay, then RESULTS OK is displayed in a green box at the center of the screen. If the results are not okay, then the errors or measurement results are displayed in the table.
Note 
RESULTS OK can be cleared by pressing Esc.
 
Note 
The measurement time can be set up in two ways: Manual (continuous), or by setting a fixed value using the Measure Time submenu in the Measurements menu (1 min, 3 min, 5 min, 15 min, 30 min, 1 hour, 2 hours, 3 hours, 1 day, 2 days, or 3 days).
 
 
 
 
BERT Table Display
Submenu keys for the BERT menu are shown in Figure: E1 Measurements Submenu Keys and are described in BERT Menu.