Backhaul Analyzer Measurement Guide : E1 Analyzer (Option 52 or 55) : Measurements Menu
 
Measurements Menu
When not active, some submenu keys have no arrow to indicate a sub menu, and the circular indicator has a plain background. The circular indicator with a red background and the sub menu arrow appear only when these submenu keys are active.
Key Sequence: Measurements
E1 Measurements Menu
BERT
Press this submenu key to open the BERT Menu. If not already selected, press this submenu key once to select the function, and the submenu key label displays the circle indicator in red (to show that the key is active). Press the key again to enter the BERT menu.
Rx Signal
This submenu key has an indicator which is displayed with a red background when the function is active. The submenu key opens a table of BERT indications and their values:
Frequency
Frequency Max
Frequency Min
Vpp
Vpp Max
Vpp Min
dBdsx
Clock Slips
Frame Slips
VF
Press this submenu key once to display the frequency and power of VF signals. Press the submenu key again to open the VF Menu for configuration.
Measure Time
This submenu key opens a dialog box to set the measurement time from 1 minute (minimum) to 3 days (maximum) or set to Manual. Use the arrow keys or the rotary knob to enter a value, and then press Enter or the Rotary Knob to continue, or press Esc to abort.
Clear History
Press this submenu key to erase the history of displayed events and measurements.
Save Results
Press this submenu key to save the results of a measurement.