WiMAX Signal Analyzer Measurement Guide : Fixed WiMAX Signal Analyzer : Fixed WiMAX Demodulator : Modulation Summary
 
Modulation Summary
The Modulation Summary displays the critical Modulation transmitter performance measurements in a table format by demodulating the WiMAX signal. The numerical results that are displayed in the Modulation summary table are: RCE (rms) in dB, RCE (pk) in dB, EVM (rms) in %, EVM (pk) in %, Freq Error in Hz, Freq Error in ppm, Carrier Frequency in Hz, Base Station ID.
Procedure:
1. Setup the measurement as described in Setup for Fixed WiMAX Demodulator Measurements.
2. Press the Measurements main menu key.
3. Press the Demodulator submenu key.
4. Press the Modulation Summary submenu key to activate the measurement. The sample image in Figure: Fixed WiMAX Modulation Summary may differ from any image on your instrument.
Fixed WiMAX Modulation Summary