Backhaul Analyzer Measurement Guide
:
OC-3c Analyzer (Option 58)
:
Error/Alarm Menu
Error/Alarm Menu
Key Sequence:
Error/Alarm
Error/Alarm Menu
Alarm Ins Setup
Opens the
Alarm Ins Menu
.
Error Ins Setup
Opens the
Error Ins Menu
.
Alarm Insert
When On, activates the selected Alarm for transmission path insertion.
Error Insert
When On, activates the selected Error for transmission path insertion.
Alarm Ins Menu
Key Sequence:
Error/Alarm
> Alarm Ins Setup
Alarm Ins Menu
Use this menu to add an alarm to the transmission path. Press the submenu key of the desired alarm:
Line AIS
Line RDI
Path AIS
Path RDI
Alarm Insert Off/On
Press this key to toggle on or off the selected alarms above.
Back
Press this key to return to the
Error/Alarm Menu
.
Error Ins Menu
Key Sequence:
Error/Alarm
> Error Ins Setup
Error Ins Menu
Use this menu to add an error to the transmission path. Press the submenu key of the desired error.
Section BIP
Line BIP
Path BIP
Error Insert Off/On
Press this key to toggle on or off the selected errors above.
Back
Press this key to return to the
Error/Alarm Menu
.