Backhaul Analyzer Measurement Guide : T1/T3 Analyzer (Option 53)  : T3 Measurements Menu : BERT Menu
 
BERT Menu
When the configuration is for a DS3 Test Mode with a DS1 Payload Type, the BERT measurement menu offers both DS1 and DS3 Table submenu keys. When the configuration is for a DS3 Test Mode with a Payload Type of 45 Mb, the BERT menus has one Table key.
Key Sequence: Measurements > BERT
DS3 BERT Menu with DS1 Payload
DS1 Table
Press this submenu key to display the 10 BERT parameters and their settings in a table format.
DS3 Table
Press this submenu key to display the DS3 Results table that consists of BPV, Frame Bits, P‑bit Errors, C‑bit Errors, and FEBE Errors.
Histogram
Press this submenu key once to make it active and to display a histogram of parameters. Press the submenu key again to display the Histogram Menu.
Event List
Press this submenu key to display a chronological event list with 4 columns. The column labels are “Date”, “Time”, “Event Type”, and “Events.”
Clear History
Press this submenu key to erase the history of displayed events and measurements. Pressing this submenu key also clears any red History indicators in the yellow‑highlighted upper measurement display.
Back
Press this submenu key to return to the T3 Measurements Menu.