Land Mobile Radio Analyzer and Coverage Measurement Guide : P25 Phase 2 Analyzer (Option 521) : P25p2 IQ Data
 
P25p2 IQ Data
Note 
This measurement is captured on an external USB flash drive. The captured data file cannot be recalled and displayed on the instrument screen.
The LMR Master can capture and log P25p2 IQ data to a USB flash drive.
1. From the Frequency main menu, set the receiver frequency (Rx Freq).
2. Insert a formatted USB flash drive into the LMR Master and from the Measurement main menu, press the P25p2 IQ Capture submenu key. After approximately 10 seconds, the instrument displays a message that the capture is complete.
The IQ data is sampled at 4,800 x 11 symbols per second. The saved file has an ASCII header and binary data (Figure: IQ Capture). The data is written in 24‑bit two’s complement integer format. The file is intended for post‑processing in MATLAB or other data analysis software.
The file will be written to a data stamped folder inside the /usr folder on the root level of the USB flash drive. The file is named:
IQ_CAPTUREyearmonthdaytime.p252
Note 
There is no display menu for P25p2 IQ Capture. The LMR Master will continue to display the previous measurement screen during IQ Capture.
IQ Capture