VNA Master™Programming Manual : VNA Commands : [:SENSe]:CORRection:CKIT:USER Subsystem
 
[:SENSe]:CORRection:CKIT:USER Subsystem
This subsystem contains commands to configure the user device under test (DUT).
 
DUT User Inductance Coefficient value
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX:SOLT:L0|1|2|3
Description
Sets the DUT inductance value for the specified Short component of the user-defined SOLT Cal Kit.
Syntax
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX:SOLT:
L0|1|2|3 <inductance>
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX:SOLT:
L0|1|2|3?
Cmd Parameter
<NRf> <inductance> (e‑12, e‑24, e‑34, e‑42)
Query Response
<NR3> <inductance> (e‑12, e‑24, e‑34, e‑42)
Example
To set the DUT inductance L1 for User 1 with line type coax to 5:
:SENS:CORR:CKIT:USER:COAX:SOLT:L1 5
To query the DUT inductance L1 for User 1:
:SENS:CORR:CKIT:USER:COAX:SOLT:L1?
The query response would be: 5.000
Front Panel Access
Shift-2 (Calibrate), DUT Port Setup, Setup User‑Defined, Short
 
DUT User Capacitance Coefficient value
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX:SOLT:C0|1|2|3
Description
Sets the DUT capacitance value for the specified user.
Syntax
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX:SOLT
:C0|1|2|3 <capacitance>
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX:SOLT
:C0|1|2|3?
Cmd Parameter
<NRf> <capacitance> (e‑15, e‑27, e‑36, e‑45)
Query Response
<NR3> <capacitance> (e‑15, e‑27, e‑36, e‑45)
Example
To set the DUT capacitance #1 for User 1 with line type coax to 5:
:SENS:CORR:CKIT:USER:COAX:SOLT:C1 5
Front Panel Access
NA
 
DUT User Name
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX:SOLT:NAME
Description
Sets the DUT name for the specified user.
Syntax
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX
:SOLT:NAME <string>
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX
:SOLT:NAME?
Cmd Parameter
<string> (no parameter data or units)
Query Response
<string> (no parameter data or units)
Example
To set the DUT name for User 1 with line type coax and calibration method SOLT:
:SENS:CORR:CKIT:USER:COAX:SOLT:NAME “SOLT1”
Front Panel Access
NA
 
DUT User Open Offset
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX:SOLT:OPEN
Description
Sets the DUT capacitance value for the specified user.
Syntax
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX:SOLT:OPEN <length>
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX:SOLT:OPEN?
Cmd Parameter
<NRf> <length> (millimeters)
Query Response
<NR3> <length> (millimeters)
Example
To set the DUT open offset for User 1 with line type coax to 3 mm:
:SENS:CORR:CKIT:USER:COAX:SOLT:OPEN 3
Front Panel Access
NA
 
DUT User Short Offset for calibration method SOLT
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX:SOLT:SHORt
Description
Sets the DUT capacitance value for the specified user.
Syntax
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX:SOLT:SHORt <length>
[:SENSe]:CORRection:CKIT:USER[1]|2|3|4:COAX:SOLT:SHORt?
Cmd Parameter
<NRf> <length> (millimeters)
Query Response
<NR3> <length> (millimeters)
Example
To set the DUT short offset for User 1 with line type coax to 3 mm:
:SENSe:CORRection:CKIT:USER:COAX:SOLT:SHORt 3
Front Panel Access
NA