:SENSe{1-16}:NFIGure Subsystem
 
:SENSe{1-16}:NFIGure:NOISe:CALibration[:STATe]?
Description
Query only.
Returns the state of whether the Noise Figure noise is applied or not for the indicated channel.
Cmd Parameters
NA
Query Parameters
NA
Query Output:
<NR1> 0 | 1
Range
NA
Default
0
Syntax Example
:SENS1:NFIG:NOIS:CAL?
:SENSe{1-16}:NFIGure:LOAD:RCVR:CALibration:DATA <filespec>
Description
Loads the Noise Figure receiver data for the indicated channel.
No query.
Cmd Parameters
<string> Filename and path in the form: 'x:\directory\filename.rcvr', where
x:\directory\filename.rcvr must exist. See Programming the VectorStar Series VNA, Notational Conventions for more information.
Query Parameters
NA
Query Output:
NA
Range
NA
Default
NA
Syntax Example
:SENS1:NFIG:LOAD:RCVR:CAL:DATA 'c:\AnritsuVNA\rcvrfilename.rcvr'
:SENSe{1-16}:NFIGure:RCVR:CALibration:PERForm?
Description
Query only.
Performs the Noise Figure receiver calibration for the indicated channel.
Cmd Parameters
NA
Query Parameters
NA
Query Output:
<NR1> 1 | 0 where
0 = Successful completion of the calibration
1 = Error in the calibration
Range
NA
Default
NA
Syntax Example
:SENS1:NFIG:RCVR:CAL:PERF?
 
:SENSe{1-16}:NFIGure:RCVR:CALibration[:STATe]?
Description
Query only.
Returns the state of whether the Noise Figure receiver calibration is applied or not to the indicated channel.
Cmd Parameters
NA
Query Parameters
NA
Query Output:
<NR1> 1 | 0
Range
NA
Default
0
Syntax Example
:SENS1:NFIG:RCVR:CAL?