![]() | SCALE (Real) Menu This menu is available when TRACE FORMAT is set to Real. Button units are set to: • Button Units: U (Units) Resolution (Units/Div) Select displays the Resolution (Units/Division) toolbar with units of units per division. Resolution (Units/Div) Field Toolbar ![]() Reference Value (Units) Select displays the Reference Value (Units) toolbar. Reference Value (Units) Field Toolbar ![]() Reference Position (Number) Select displays the Reference Position toolbar. Reference Position (Number) Field Toolbar ![]() Additional Common Buttons |
![]() | SCALE (Imaginary) Menu This menu is available when TRACE FORMAT is set to Imaginary. Button units are set to: • Button Units: U (Units) Resolution (Units/Div) Select displays the Resolution (Units/Division) toolbar with units of units per division. Resolution (Units/Division) Field Toolbar ![]() Reference Value (Units) Select displays the Reference Value (Units) toolbar. Reference Value (Units) Field Toolbar ![]() Reference Position (Number) Select displays the Reference Position toolbar. Reference Position (Number) Field Toolbar ![]() Additional Common Buttons |
![]() | SCALE (Impedance Real) Menu This menu is available when TRACE FORMAT is set to Impedance - Magnitude. Button units are set to: • Button Units: Ω (Ohms) Resolution (Ohms/Div) Select displays the Resolution (Ohms/Division) toolbar with units in Ohms per division. Resolution (Ohms/Div) Field Toolbar ![]() Reference Value (Ohms) Select displays the Reference Value (Ohms) toolbar with units in Ohms. Reference Value (Ohms) Field Toolbar ![]() Reference Position (Number) Select allows the user to define a reference position and displays the Reference Position field toolbar. Reference Position (Number) Field Toolbar ![]() Additional Common Buttons |
![]() | SCALE (Impedance Imaginary) Menu This menu is available when TRACE FORMAT is set to Impedance - Imaginary. Button units are set to: • Button Units: Ω (Ohms) Resolution (Ohms/Div) Select displays the Resolution (Ohms/Division) toolbar with units in Ohms per division. Resolution (Ohms/Div) Field Toolbar ![]() Reference Value (Ohms) Select displays the Reference Value (Ohms) toolbar with units in Ohms. Reference Value (Ohms) Field Toolbar ![]() Reference Position (Number) Select allows the user to define a reference position and displays the Reference Position field toolbar. Reference Position (Number) Field Toolbar ![]() Additional Common Buttons |
![]() | SCALE (Inductance) Menu This menu is available when TRACE FORMAT is set to Impedance - Inductance. Button units are set to: • Button Units: H (Henrys) Resolution (H/Div) Select displays the Resolution (H/Division) toolbar with units in Henrys per division. Resolution (H/Div) Field Toolbar ![]() Reference Value (H) Select displays the Reference Value (H) toolbar with units in Henrys. Reference Value (H) Field Toolbar ![]() Reference Position (Number) Select allows the user to define a reference position and displays the Reference Position field toolbar. Reference Position (Number) Field Toolbar ![]() The selected trace display is redrawn according to the scale settings entered. The trace annotation changes accordingly. Additional Common Buttons |
![]() | SCALE (Capacitance) Menu This menu is available when TRACE FORMAT is set to Impedance - Capacitance. Button units are set to: • Button Units: F (Farads) Resolution (F/Div) Select displays the Resolution (Farads/Division) toolbar with units in Farads per division. Resolution (F/Div) Field Toolbar ![]() Reference Value (F) Select displays the Reference Value (Farads) toolbar with units in Farads. Reference Value (F) Field Toolbar ![]() Reference Position (Number) Select allows the user to define a reference position and displays the Reference Position field toolbar. Reference Position (Number) Field Toolbar ![]() The selected trace display is redrawn according to the scale settings entered. The trace annotation changes accordingly. Additional Common Buttons |