VectorStar™ MS464xB Series Microwave Vector Network Analyzer User Interface Reference : Scale Menus : SCALE Dual-Trace Display Menus
 
SCALE Dual-Trace Display Menus
SCALE Impedance Real and Imaginary Menu
Menu Identification
The appearance and button availability of the SCALE menu depends on the settings on the DISPLAY menu. Consult Scale Menus Appearance, Common Buttons, and Units for SCALE menu identification and prerequisites.
Previous
MAIN Menu
Navigation
MAIN | Scale | SCALE
SCALE Impedance Real and Impedance Imaginary Menu (1 of 2)
SCALE (Impedance Real & Impedance Imaginary) Menu
This menu is available when TRACE FORMAT is set to Impedance - Real & Impedance - Imaginary. There are separate button sets for Impedance-Real and Impedance-Imaginary. Button units are set to:
Button Units: Ω (Ohms)
 
Impedance Real Button Set
Resolution (Ohms/Div)
Select displays the Resolution (Ohms/Division) toolbar with units in Ohms per division.
Resolution (Ohms/Div) Field Toolbar
Reference Value (Ohms)
Select displays the Reference Value (Ohms) toolbar with units in Ohms.
Reference Value (Ohms) Field Toolbar
Reference Position (Number)
Select allows the user to define a reference position and displays the Reference Position field toolbar.
Reference Position (Number) Field Toolbar
 
 
Impedance Imaginary Button Set
Resolution (Ohms/Div)
Select displays the Resolution (Ohms/Division) toolbar with units in Ohms per division.
Resolution (Ohms/Div) Field Toolbar
Reference Value (Ohms)
Select displays the Reference Value (Ohms) toolbar with units in Ohms.
Reference Value (Ohms) Field Toolbar
Reference Position (Number)
Select allows the user to define a reference position and displays the Reference Position field toolbar.
Reference Position (Number) Field Toolbar
 
Additional Common Buttons
 
SCALE Log Magnitude and Phase Menu
Menu Identification
The appearance and button availability of the SCALE menu depends on the settings on the DISPLAY menu. Consult Scale Menus Appearance, Common Buttons, and Units for SCALE menu identification and prerequisites.
Previous
MAIN Menu
Navigation
MAIN | Scale | SCALE
SCALE Log Magnitude and Phase Menu (1 of 2)
SCALE (Log Magnitude & Phase) Menu
This menu is available when TRACE FORMAT is set to Log Magnitude and Phase. There are separate button sets for Log Magnitude and Phase. Button units are set to:
Button Units: dB
Button Units: º (Degrees)
Log Magnitude Area Button Set
Resolution (dB/Div)
Select displays the Resolution (dB) toolbar with units in dB per division.
Resolution (dB/Division) Field Toolbar
Reference Value (dB)
Select displays the Reference Value (dB) toolbar.
Reference Value (dB) Field Toolbar
Reference Position (Number)
Select displays the Reference Position toolbar.
Reference Position (Number) Field Toolbar
Phase Area Button Set
Resolution (Degs/Div)
Select displays the Resolution (Degrees/Division) toolbar with units in degrees per division.
Resolution (Degs/Div) Field Toolbar
Reference Value (Degrees)
Select displays the Reference Value (Degrees) toolbar.
Reference Value (Degrees) Field Toolbar
 
Reference Position (Number)
Select displays the Reference Position toolbar.
Reference Position (Number) Field Toolbar
Wrap Setup
Select opens the Wrap Setup menu and allows the user to toggle wrapping On and Off, and define the phase offset in degrees which, when selected, displays the Wrap Offset field toolbar: See the WRAP Setup Menu.
Wrap Offset (Degrees) Field Toolbar
Additional Common Buttons
SCALE Linear Magnitude and Phase Menu
Menu Identification
The appearance and button availability of the SCALE menu depends on the settings on the DISPLAY menu. Consult Scale Menus Appearance, Common Buttons, and Units for SCALE menu identification and prerequisites.
Previous
MAIN Menu
Navigation
MAIN | Scale | SCALE
SCALE Linear Magnitude and Phase Menu (1 of 2)
SCALE (Linear Magnitude & Phase) Menu
This menu is available when TRACE FORMAT is set to Linear Magnitude and Phase. Button units are set to:
Button Units: U (Units)
Button Units: º (Degrees)
There are separate button sets for Linear Magnitude and Phase.
Linear Magnitude Area Button Set
Resolution (Units/Div)
Select displays the Resolution (Units/Division) toolbar with units of units per division.
Resolution (Units/Div) Field Toolbar
Reference Value (Units)
Select displays the Reference Value (Units) toolbar.
Reference Value (Units) Field Toolbar
Reference Position (Number)
Select displays the Reference Position toolbar.
Reference Position (Number) Field Toolbar
Phase Area Button Set
Resolution (Degs/Div)
Select displays the Resolution (Degrees/Division) toolbar with units in degrees per division.
Resolution (Degs/Div) Field Toolbar
Reference Value (Degs)
Select displays the Reference Value (Degrees) toolbar.
Reference Value (Degrees) Field Toolbar
 
Reference Position (Number)
Select displays the Reference Position toolbar.
Reference Position (Number) Field Toolbar
Wrap Setup
Select opens the Wrap Setup menu and allows the user to toggle wrapping On and Off, and define the phase offset in degrees which, when selected, displays the Wrap Offset field toolbar: See the WRAP Setup Menu.
Wrap Offset (Degrees) Field Toolbar
Additional Common Buttons
SCALE Real and Imaginary Menu
Menu Identification
The appearance and button availability of the SCALE menu depends on the settings on the DISPLAY menu. Consult Scale Menus Appearance, Common Buttons, and Units for SCALE menu identification and prerequisites.
Previous
MAIN Menu
Navigation
MAIN | Scale | SCALE
SCALE Real and Imaginary Menu (1 of 2)
SCALE (Real & Imaginary) Menu
This menu is available when TRACE FORMAT is set to Real and Imaginary. Button units are set to:
Button Units: U (Units)
There are separate button sets for Real and Imaginary.
Real Area Button Set
Resolution (Units/Div)
Select displays the Resolution (Units/Division) toolbar with units of units per division.
Resolution (Units/Div) Field Toolbar
Reference Value (Units)
Select displays the Reference Value (Units) toolbar.
Reference Value (Units) Field Toolbar
Reference Position (Number)
Select displays the Reference Position toolbar.
Reference Position (Number) Field Toolbar
Imaginary Area Button Set
Resolution (Units/Div)
Select displays the Resolution (Units/Division) toolbar with units of units per division.
Resolution (Units/Div) Field Toolbar
 
 
Reference Value (Units)
Select displays the Reference Value (Units) toolbar.
Reference Value (Units) Field Toolbar
Reference Position (Number)
Select displays the Reference Position toolbar.
Reference Position (Number) Field Toolbar
Additional Common Buttons