Signal Standard Editor
The Signal Standard Editor allows you to edit or add to a signal standard file which contains definitions of multiple signal standards. You can also upload the new signal standard definitions into the instrument in use or export them locally onto a PC.
Signal Standard Editor
Connected to an Instrument
Add a Signal Standard
1. Click Signal Standard Editor in the Tools menu.
• The Signal Standard Editor opens with the parameters, from the instrument in use, loaded into the editor.
2. Press the Add New button on the toolbar.
• The cursor moves to the empty field after the list of filled fields.
3. Enter the name of the signal standard and its parameters in the left column of entry windows in the Signal Standard Editor.
• Clicking the new entry updates the value in the parameter matrix.
4. Click the Upload to Instrument command in the Capture menu or the press the F3 button on the PC keyboard to upload the new cable list to the instrument. Or, press the Export button on the toolbar to save the list locally on the PC.
Edit/Change a Signal Standard Parameters
1. Click Signal Standard Editor in the Tools menu.
• The Signal Standard Editor opens with the parameters, from the instrument in use, loaded into the editor.
2. Press the Open button on the toolbar to edit a previously saved signal standard list.
3. Select the desired signal standard in the list.
4. Enter the parameter values for the existing signal standard.
5. Click the Upload to Instrument command in the Capture menu or the press the F3 button on the PC keyboard to upload the new cable list to the instrument. Or, press the Export button on the toolbar to save the list locally on the PC.
Disconnected from an Instrument
Create a New Signal Standard List
1. Click Signal Standard Editor in the Tools menu.
• The Signal Standard Editor opens with the parameter fields empty.
2. Press the Add New button on the toolbar.
• The cursor moves to the empty field after the list of filled fields.
3. Enter the name of the signal standard and its parameters in the left column of entry windows in the Signal Standard Editor.
• Clicking the new entry updates the value in the parameter matrix.
4. Repeat Step 2 and Step 3 until all signal standards have been entered.
5. Press the Export button on the toolbar to save the list locally on the PC.
Add a New Signal Standard
1. Click Signal Standard Editor in the Tools menu.
• The Signal Standard Editor opens with the parameter fields empty.
2. Press the Open button on the toolbar.
• The Open a Signal Standard File dialog opens.
3. Highlight the desired signal standard file and press Open.
4. On the toolbar, press the Add New button.
• The cursor moves to the empty field after the list of filled fields.
5. Enter the name of the signal standard and its parameters in the left column of entry windows in the Signal Standard Editor.
• Clicking the new entry updates the value in the parameter matrix.
6. Repeat Step 4 and Step 5 until all signal standards have been entered.
7. Press the Export button on the toolbar to save the list locally on the PC.
Edit/Change an Existing Signal Standard’s Parameters
1. Click Signal Standard Editor in the Tools menu.
• The Signal Standard Editor opens with the parameter fields empty.
2. Press the Open button on the toolbar.
• The Open a Signal Standard File dialog opens.
3. Highlight the desired signal standard file in the list.
4. Press the Open button.
5. Scroll to the desired signal standard or enter the number of the signal standard in the entry window.
6. Enter/change the parameter values for the existing signal standard.
• Clicking the new entry updates the value in the parameter matrix.
7. Press the Export button on the toolbar to save the signal standard list locally on the PC.
Note 
All entry units are in MHz.
Signal Standards with the same start and stop frequencies are UMTS Standard Signals. They only have one channel in the band so only the center frequency is entered as start and stop frequencies.