: Instrument Operation : Frequency Step Sweep Operation : Step Sweep SETUP Menu
 
Step Sweep SETUP Menu
Pressing STEP from the SWEEP menu displays the SETUP menu. When the STEP SWEEP button is toggled on, the status bar displays Step Sweep - Single. Note that the sweep displayed at the status bar is dependent on the sweep selected in the TRIGGER menu. The sweep displayed at the status bar is dependent on the sweep selected from the SUMAMARY menu or from the TRIGGER menu. See TRIGGER Menu.
Press: SWEEP | STEP | SETUP
Step Sweep SETUP Menu
START
Set the start frequency of the step sweep.
STOP
Set the stop frequency of the step sweep.
STEP SIZE
Set the step size of the step sweep.
NUMBER OF POINTS
Set the number of points in a step sweep. Range is 2 to 65535.
DWELL TIME
Sets the sweep per point dwell time. Units are in seconds. Range is 1e-05 s to 99 s
SWEEP DIRECTION
Sets the direction of the sweep up/down.
Up = sweeps from start to stop sweep.
Down = sweeps from stop to start sweep.
PRESET SWEEP RANGES
Selects a frequency sweep range preset.
Range: F1F2|F3F4|F5DF|F6DF
SWEEP TYPE
Sets the parameter for sweep type to Logarithmic or Linear sweep operation.
STEP SWEEP
Toggle step sweep on or off.