Note | Not all after-market USB drives are compatible with Field Master. The USB drive must contain a single partition using either FAT32, exFAT, NTFS and ext4 file formats. |
Model | Frequency Range |
---|---|
MS2070A‑0703 | Spectrum Analyzer, 9 kHz to 3 GHz |
MS2080A‑0704 | Spectrum Analyzer, 9 kHz to 4 GHz |
MS2080A‑0706 | Spectrum Analyzer, 9 kHz to 6 GHz |
Option | Description |
---|---|
MS2080A‑0003* | Time Domain Reflectometry (TDR) Measurements |
MS2070A-0005 | Wi-Fi Connectivity |
MS20x0A-0006 | Remove Wi-Fi and Bluetooth |
MS20x0A-0007 | Secure Data Operation |
MS2070A-0008 | Preamplifier |
MS2070A/80A‑0017 | Secure Communications |
MS2070A/80A‑0019* | High Accuracy Power Meter (Requires USB power sensor, sold separately) |
MS2080A-0020 | Tracking Generator |
MS2080A‑0024* | Interference Finder (Requires Option 31, and directional antenna recommended, sold separately) |
MS2070A/80A‑0027* | Channel Scanner |
MS2080A‑0031* | GNSS Receiver (Requires GNSS antenna, sold separately) |
MS2080A-0090* | Gated Sweep |
MS2080A-0102* | 40 MHz Analysis Bandwidth |
MS2080A-0126* | IQ Waveform Capture (Includes MX280005A IQ Signal Master base feature set) (Non-Export Controlled) |
MS2080A-0127* | IQ Waveform Capture (Includes MX280005A IQ Signal Master base feature set) (Non-Export Controlled) |
MS2089A-0128* | Enable Vector Signal Analysis (Requires Option 126; use with MX280005A) |
MS2080A-0199* | Real-Time Spectrum Analysis (RTSA) |
MS2080A-0400* | Enable Vision Monitor |
MS2080A-0407* | Enable Vision High Speed Port Scanner |
MS2080A-0431* | Coverage Mapping (Requires Option 31, cannot be ordered with Option 9031) |
MS2080A-0444* | EMF Measurement |
MS2080A-0509* | AM/FM Modulation Measurements |
MS2080A-0871* | WCDMA Measurement (Requires Option 31) |
MS2080A-0883* | LTE FDD/TDD Measurement (Requires Option 31) |
MS2080A-0888* | 5G NR Downlink Measurements (Requires Option 31) |
MS2070A/80A‑070x-0097 | Accredited Calibration to ISO17025 and ANSI/NCSL Z540-1. Includes calibration certificate, test report, and uncertainty data. |
MS2070A/80A‑070x-0098 | Standard Calibration to ISO17025 and ANSI/NCSL Z540-1. Includes calibration certificate. |
MS2070A/80A‑070x-0099 | Premium Calibration to ISO17025 and ANSI/NCSL Z540-1. Includes calibration certificate, test report, and uncertainty data. |
* Timed-Limited Options | Options marked with an asterisk are offered as a 90-day time limited option by ordering as a -9xxx series option. For example, MS2080A-9888 is the 90-day time limited option for 5GNR FDD/TDD FR1 Measurements. The option start time begins when the user first activates the option. |
Model | Description |
---|---|
MX280001A | Vision™ Software |
MX280005A | IQ Signal Master™ Vector Signal Analysis Software |
MX280007A | Mobile InterferenceHunter™ Software |
ARRT | Anritsu Remote and Report Tool |